Graco 238515 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 238515, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 238515 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 238515. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 238515 should contain:
- informations concerning technical data of Graco 238515
- name of the manufacturer and a year of construction of the Graco 238515 item
- rules of operation, control and maintenance of the Graco 238515 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 238515 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 238515, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 238515.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 238515 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instructions - - Parts List GRACO INC. P .O. BOX 1441 MINNE APOLIS, MN 55440 - 1441 Copyright 2001, Graco Inc . is registered to I. S. EN IS O 9001 PRESET PM5 t t t t Electro n ic Metered Disp ense V alves For pre - - set met ered dispense of oils and ant ifreeze. 1000 psi (7 M Pa, 69 bar) M aximum Wor king Pressur e 5 gpm (18.9 lpm) M aximum Flow [...]

  • Page 2

    2 309377 T able of Contents W arnings 2 ...................................... Insta l la tio n 4 ..................................... Setup 7 ......................................... Oper ation 1 1 .................................... T roubleshoot ing 13 ............................... Service 16 ...................................... Parts Lis[...]

  • Page 3

    3 309377 FIRE AND EXPL OSION HAZ ARD Im proper gr ounding, poor vent ilation, open f lames, or s parks can caus e a hazardous condit ion and result in a fir e or explos ion and serious injury . D Be sure the ent ire fluid syst em is properly grounded. Refer to your pump instruct ion manual for complet e details . See Grounding on page 6. D If ther [...]

  • Page 4

    4 309377 Installation T ypical In stallations Fig. 1 shows a typic al hose r eel inst allation. These dispense v alves c an also be inst alled on a cons ole, as s h o w ni nF i g . 2 . Do not use t his dis pense v alve on non-G rac o consoles . Such us e could r esult in the t rigger becoming inadv ert ently press ed while the dis- pense valv e is [...]

  • Page 5

    5 309377 Installation PRESS URIZ ED E QUI PM ENT HAZ ARD The equipm ent s tay s pres suriz ed until pr essur e is manually r elieved. T o r educe t he risk of s erious injury f rom pres suriz ed fluid, ac cident al spray f rom the dispens e valve, or s plashing f luid, f ollow t he Pressu re Reli ef Pro ced ur e when you D Are ins tr uct ed to r el[...]

  • Page 6

    6 309377 Installation 10. T hread t he sealing nut (5c, 6c, or 7c ) ont o the ext ension (5a) or st reet elbow (6d or 7d), t hread the ext ension or elbow in at leas t t hree f ull t urns, position i t f or pr oper alignment , and tight en t he sealing nut. The P TF E s eal on the s ealing nut must fac e the v alve housing. See Fig. 4. NOT E: T h e[...]

  • Page 7

    7 309377 Setu p T erms The f ollowing ter ms ar e shown on t he display and/ or used oft en in t his ins tr uct ion manual. D R- - TOT A L: res ett able t otal Displayed t o show t he cum ulative am ount t hat the dispense v alve has dis pensed in all modes . I t can be reset t o zero. D TOT AL: non-res ett able t otal Displayed t o show t he cum u[...]

  • Page 8

    8 309377 Setu p Se lecti ng Dispe nsing Opti ons This is the pr ocedur e for sett ing or changing t he reset table t ot al, unit s of meas urement , calibrat ion f act or , aut o preset am ount, and shut -off default am ount: 1. If the dis play is as leep, wak e it up by press ing the M anual/R eset or Aut o/Res et but t on. 2. T o enter the dis pe[...]

  • Page 9

    9 309377 Setu p Ca libra tion Fa ctor In t his menu, you c an recalibr ate t he met er f or dif f erent fluids . 1. If you have not already enter ed the dis pensing options menus, do st eps 1 and 2 in S elect in g Disp ensi n g Op ti on s on page 8. 2. Pres s t he Auto/ Res et but ton r epeatedly until CAL blinks and t he cur rent calibrat ion fac [...]

  • Page 10

    10 309377 Setu p Shut-Of f De fa ult Am ount The shut- off default am ount is for prevent ing acciden- tal over fills when dispensing wit h t he tr igger lock ed in Manual mode. T he shut-off def ault amount is fac tor y preset at 5 quart s. In t his m enu, you c an change t he shut -off def ault amount . 1. If you have not already enter ed the dis[...]

  • Page 11

    11 309377 Operation Locking a nd Unlock ing the T rigger The t rigger on this dispense v alve has a loc king mec h- anism. I n Aut o mode, t he unit s tops dispensing when the ent ered am ount has been dispensed. In Manual mode, t he trigger does not automat ically unlock ; you must unloc k it manually . T o lock the tr igger , press on t he part o[...]

  • Page 12

    12 309377 Operation Dis pensing Fl uid in Auto M ode Before you begin a preset dispense cycle, make sure AUTO is displayed. I f y ou do not s ee AUTO on the display , you ar e not in t he Aut o dispense m ode, and f luid flow will not s top when the aut o preset amount is dis pensed. CAUTION 1. Pres s t he Aut o/Res et but t on. The display wakes u[...]

  • Page 13

    13 309377 T roubleshooting Reli eve th e pressu re bef ore y ou check or repair the met er . Be sure all other v alves and contr ols and t he pump are oper ating pr operly . W ARNING T o reduce t he ris k of serious injury whenev er you are inst ruc ted t o reliev e press ure, always f ollow the Pressu re Reli ef Pro ced ur e on page 5. Proble m Ca[...]

  • Page 14

    14 309377 T roubleshooting Proble m Cause Solu tion Meter le aks from: Cove r/Control Poor swivel ( 3)/ hose connec tion. Poor swivel ( 3)/m eter hous ing connect ion. Damaged valv e stem (16) assem bly . Poor seal at met er housing plat e. NOT E: Plac e a st raight edge along met er housing plate. If f lat, plat e and seal are ok. If plat e is not[...]

  • Page 15

    15 309377 T roubleshooting Error Codes Err or codes are list ed below . Even in an err or condi- tion, t he unit keeps trac k of the amount dispensed. Wit h any er ror c ode displayed, as s hown at r ight, you can D Pres s t he Manual/ Reset butt on. Err or code is cleared, unit switc hes int o Manual mode, and dispensed am ount is displayed. D Pre[...]

  • Page 16

    16 309377 Service Replacing the Batter y FIRE AND EXPLOSI ON HAZARD Only replace t he batt ery in a non-hazar dous locat ion, away f rom flam mable f luids or f umes . Y ou m ay order batt ery Part No. 1 13716 separat ely . Batt ery requir ed to m eet s afet y appr ovals: Duracell alk aline MN1604, PC1604 or Ever eady alkaline E N22, 522 W ARNING B[...]

  • Page 17

    17 309377 Service Servicing the V a lve V alve Repair K it 240453 is available and can be ordered s eparat ely . S ee the Parts List on page 18 and the Part s Draw in g on page 19. The par ts with aster isk s next t o their ref erence num bers ar e available in the V alv e Repair Kit . When y ou are repair ing the v alve wit h new part s f rom the [...]

  • Page 18

    18 309377 Parts List Ref. No. Part No. Descrip ti on Qty . 1 238554 COVE R/C ONT RO L 1 2 191351 COVE R, batt ery (included wit h 238554) 1 3 240416 SW IVE L, st raight 1 4 191286 SWI VE L COV ER, black 191287 SW IVE L COV ER, red 191288 SWI VE L COV ER, blue 191289 SW IVE L COV ER, green 191290 SWI VE L COV ER, yellow 1 5 239949 NOZZ LE ASSEMBL Y [...]

  • Page 19

    19 309377 Parts Drawing 7119B 1 T o r q u et o7t o1 0i n - l b( 0 . 8t o1 . 1N . m ) . 1 me te r housing (not available for sale) 21 1 2 T orque t o 140 to 150 in- lb (16 t o 17 N.m ). 2 3 4 25* 1 15 24 3 Apply lubr icant when reass embling. 8 6b 5a 5c 4 4 T o rq ue to 2 0 to 25 ft-l b (2 7 to 34 N .m). 7c 7a 7d solenoid (not available for sale) 27[...]

  • Page 20

    20 309377 T echnical Data Flow r ange * 0.26 t o 5 gpm ( 1 to 18. 9 lpm) ................................................. Oper ating pr essur e range 45 to 1000 psi ( 0.29 t o 7 MP a, 2. 9 t o 69 bar) ........................ Weight 3l b( 1 . 3 6k g ) .................................................................... Units of m easur ement fact [...]

  • Page 21

    21 309377 Dimensional Drawing A 14.0 in. (356 m m) out let to end of swivel cover B C A B C 3.75 in. (95 mm ) wides t c ross sect ion (inc luding impact guard) 3.10 in. (79 m m) k eypad t o bott om of impac t guar d TI 0327[...]

  • Page 22

    22 309377 Graco Standard W arranty Graco w arr ants al l equi pment m anufact ured by Gr aco and bear ing i ts name to be f r ee fr om defect s in materi al and workmanship on the date of sale t o the or igi nal pur chaser f or use. Wit h t he except ion of any special , extended, or lim it ed warr anty published by Graco, Gra co w ill, for a perio[...]