Graco 224434 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 224434, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 224434 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 224434. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 224434 should contain:
- informations concerning technical data of Graco 224434
- name of the manufacturer and a year of construction of the Graco 224434 item
- rules of operation, control and maintenance of the Graco 224434 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 224434 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 224434, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 224434.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 224434 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    307013 Rev . V First choice when quality counts. t INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 45:1 Ratio King r Pump 4050 psi (28 MPa, 279 bar) Maximum Working Pressure 90 psi (0.6 MPa, 6.2 bar) Maximum Air Input Pressure Model 224434, Series A Stubby Size, with Standa[...]

  • Page 2

    2 307013 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 9 . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    3 307013 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury . D Ground the equipment and the object being sprayed/dispensed. See Grounding on page 4. D Provide fresh air ventilation to avoid the buildup of flammable fu[...]

  • Page 4

    4 307013 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 3. T o reduce the risk of static sparking, ground the pump and all other components used or located in the spray/ dispensing area. Check your local electrical code for de[...]

  • Page 5

    5 307013 Installation 03291 Key A B C D E F G H J K L M N P R S Y Pump Pump Runaway V alve Air Line Lubricator Bleed-T ype Master Air V alve (required, for pump) Pump Air Regulator Air Line Filter Bleed-T ype Master Air V alve (for accessories) Air Supply Hose Fluid Drain V alve (required) Fluid Supply Hose Spray Gun Fluid Suction Hose Exhaust Port[...]

  • Page 6

    6 307013 Installation NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Accessories are available from your Graco distributor . If you supply your own accessories, be sure the are adequately sized and pressure-rated to meet the system ’ s requirements. The T ypical Ins[...]

  • Page 7

    7 307013 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause serious injury . T o reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D are instructed to relieve the pressure, D stop spraying[...]

  • Page 8

    8 307013 Operation W ARNING Moving parts can pinch or amputate your fingers or other body parts. When air is supplied to the motor , the air motor piston (located behind the air motor shield) moves. Therefore, never operate the pump with the ar motor shield removed. Flush the Pump Before Using The pump is tested with lightweight motor oil, which is[...]

  • Page 9

    9 307013 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before servicing this equipment always make sure to Relieve the Pressure . Note: Check all possible causes and solutions before disassembling the pump. Problem Cause Solutio[...]

  • Page 10

    10 307013 Service W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Disconnecting the Displacement Pump 1. Flush the pump, if possible. Stop the pump at the bottom of its stroke. Relieve the pressure. 2. Disconnect the air and fluid hoses. Remove th[...]

  • Page 11

    11 307013 Service 03293 Fig. 2 1 2 28 31 26 A B S T 1 2 T orque to 40 – 50 ft-lb (54 – 68 N S m) T orque to 145 – 155 ft-lb (195 – 210 N S m) 1 2 1 Model 224434 shown 32 33[...]

  • Page 12

    12 307013 Parts Model 224434, Series A Stubby Size, with Standard Air Motor and Severe-Duty Displacement Pump with leather packings Includes items 1 – 33 Ref. No. Part No. Description Qty . 1 207647 AIR MOTOR See Manual 306968 for parts 1 2 224435 DISPLACEMENT PUMP ASSY See Manual 307728 for parts 1 26 101712 NUT , lock; 5/8 – 11 3 28 102176 WR[...]

  • Page 13

    13 307013 Notes[...]

  • Page 14

    14 307013 Dimensions Mounting Hole Layout 2.0 ” (51 m m ) 03290 A B Pump A B Model 224434, 42.5 in. 21 in. (1079.5 mm) (533.4 mm) 3/4 npt(f) AIR INLET 1 ” npt(f) FLUID OUTLET 1 – 1/2 ” npt(f) FLUID INT AKE See 306968 for Air Motor Dimensional Drawing. WEIGHT : 1 10 lb (50 kg) 1.875 ” (48 mm) FOR OUTLET RISER TUBE 3.712 ” (94 mm) 3.464 ?[...]

  • Page 15

    15 307013 T echnical Data Category Data Maximum fluid working pressure 4050 psi (28 MPa, 279 bar) Maximum air pressure (see cover) 90 psi (0.6 MPa, 6.2 bar) Pump cycles per 1 gallon (3.8 liters) 16 Fluid flow at 50 cpm 3.3 gpm (12 liter/min) Wetted parts See displacement pump manual 307728 Sound Pressure Levels (dBa) (measured at 1 meter from unit)[...]

  • Page 16

    16 307013 The Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use. With the exception of any special, extended , or limited warranty published by Graco, Graco will[...]