A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 216-119, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 216-119 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 216-119. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 216-119 should contain:
- informations concerning technical data of Graco 216-119
- name of the manufacturer and a year of construction of the Graco 216-119 item
- rules of operation, control and maintenance of the Graco 216-119 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 216-119 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 216-119, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 216-119.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 216-119 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    WARNING Before cleaning the gun nozzle or attempting to service Be sure your installation complies with all applicable the gun or other components, always turn off the high local codes. voltage first, then shut down paint pump and trigger gun to relieve fluid pressure. ALWAYS use the lowest pressure possible when Grounding flushing and use a ground[...]

  • Page 3

    NOTE: When increasing to a wide, flat pattern, increase supply of fluid to gun to maintain same coverage over larger area. Direction of spray pattern (horizontal or vertical) is changed by loosening lock ring and turning air cap to the desired position. TIGHTEN LOCK RING HAND TIGHT. DO NOT OVERTIGHTEN. Normal Spray Pattern .::>: 0 Proper adjustm[...]

  • Page 4

    should be taken when starting threads. Applied vide you with years of durability and efficiency These working parts require periodic replacement: 1. Air cap (7). 2. Fluid tip (6). 3. Needle, fluid (41). Removing Fluid Tip To remove fluid tip (6) for cleaning or replacement, remove the ring nut (8) and air cap (71, turn off the atomizing air, trigge[...]

  • Page 5

    ELECTROSTATIC AUTOMATIC AIR SPRAY GUN Model 216-119 47 CHAMFERED END TOWARD NEEDLE Ref No. 39 Air Adjusting Screw Assy includes items / 26-26 and 36. HAND TIGHT (27-34 N-m) Torque to 15-19 ft-lb C20-25 N-m) I REF PART DESCRIPTION NO. 103649 +103-823 722-615 +155-685 172-191 177-062 177-033 176-387 176-388 217-013 Series”B” l 103338 l 103-523 ?[...]

  • Page 6

    AIR CAP CONSUMPTION AND FLUID TIP FLOW RATE CHART Approximate 5 Pattern Length Air Consumption 177-666 177-d 177461 177463 Fluid Tip Part No / . Air Cap 254 mm (10 in) 177532 355-710 591-1182 la351479 FLOW Rate Part Number from gun ma/min @ 2.06 bar (CFM e, 30 PSI) Description 6-18 12-24 20-40 3550 ml/min 1 mm 1.2 mm 1.5 mm 1.8 mm oz/min fO.040 in)[...]

  • Page 7

    ACETONE .05 MEG. 0.6 15 TEXTILC SPIRITS 1.06 < o* BENZENE 1.2 <s TRICHLOA- 1.3 NONE ETHYLENE ETHYL ACETATE 1 A 29’ 0.46 MEG. I I MEK .05 MEG. 1.5 35 METHVL ALCOHOL 1.6 40’ 0. RES. SC-1 2.5 a soLvcSSodo TOLUOL 2.7 41 1.NITRO PROPANE ETHYL ALCOHOL D2 MEG. SOPROPVL ALCOHOL D 1. MEG 29 3.0 3.6 do 55 .-_-. . -----..-- 11.6 99 0.6 TO 36 MEG. ME[...]

  • Page 8

    DIMENSIONAL DRAWING ,. . . , * 0.5” (13 mm) DIA MOUNTING ROD HOLE MAX WIDTH 1.31” (33.3 mm1 FLUID INLET ACCESSORIES (Must be purchased separately) TECHNICAL DATA STRAINER (AIR OR PAINT) 202-271 Uses the following filter screen: 157-332 (40 mesh) 156-967 (60 mesh) cr -’ 156-939 (100 mesh) v 6 cd cdl Maximum operating voltage: 100,000 volts Max[...]