Gossen 15122 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Gossen 15122, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Gossen 15122 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Gossen 15122. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Gossen 15122 should contain:
- informations concerning technical data of Gossen 15122
- name of the manufacturer and a year of construction of the Gossen 15122 item
- rules of operation, control and maintenance of the Gossen 15122 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Gossen 15122 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Gossen 15122, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Gossen service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Gossen 15122.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Gossen 15122 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DIGISIX Exposure meter for ambient light 15122 1/06.02 Operating Instructions[...]

  • Page 2

    2 GOSSEN Foto- und Lichtmeßte chnik Setting window Display Setting ring: TIME/ Shutter speed Diffuser Setting ring: Aperture/ f-stops Measuring key Function button Eyelet for carrying strap Battery compartment Socket for tripod Camera mounting clip (accessor y)[...]

  • Page 3

    GOSSEN Foto- und Lichtmeßte chnik 3 Content 1 The functioning of th e Digisix ..... 4 1.1 Preparation and self-test ................ 4 1.2 Incident light and reflected light measuring mode 5 1.3 Duration of read-out in display ....... 5 2 Functions of the Digisix .............. 6 2.1 Setting the film speed ..................... 6 2.2 Exposure meas[...]

  • Page 4

    GOSSEN Foto- und Lichtmeßte chnik 4 1 The function ing of the Digi six 1.1 Preparation and self-test Battery The Digisix is powered by a 3 V Lithium battery, type CR 2032. When the battery is running low, the signal BA T appears in the display. – The battery should be replaced as soon as possible. When BA T is shown alone in the display, the bat[...]

  • Page 5

    GOSSEN Foto- und Lichtmeßte chnik 5 1.2 Incident light and reflec ted light measuring mo de Incident light meth od For the incident mode, the diffusor is to be shifted to the left and placed in front of the measuring aperture. Taking measurements using the incident light mode in particular produces perfectly exposed shots. In th is mode, the DS me[...]

  • Page 6

    GOSSEN Foto- und Lichtmeßte chnik 6 2 Function s of the Di gisix Press the function button for selecting the individual functions of the Digisix . Each time the button is pushed, the next function will be activated. The display panel will s how the functions in the following sequence.: • Exposure metering •T i m e r •W a t c h •A l a r m c[...]

  • Page 7

    GOSSEN Foto- und Lichtmeßte chnik 7 – Confirm the speed you selected by pushing the Function button until the OK-signal sounds and the Digisix returns to the function "EXPOSURE". The film speed is shown in the upper right corner of the display. If the film speed is changed, the measure- ment read-out stored in the memory will be immedi[...]

  • Page 8

    GOSSEN Foto- und Lichtmeßte chnik 8 – Transfer that EV value from the display to the setting window in the calculator rings and align it opposite the setting mark in the setting window. – All the suitable combinations of aperture (f-stops) - t (shutter speed) can now be seen at the upper part of the circular scales (see previous example) . 2.2[...]

  • Page 9

    GOSSEN Foto- und Lichtmeßte chnik 9 2.3 Contrast measurements – Use the Function button to select the function "EXPOSURE". – Keep the measuring key M pressed down and the meter will switch over to contrast measurement. Continue holding down the key to measure various other areas in the subject. In the display, the difference between [...]

  • Page 10

    GOSSEN Foto- und Lichtmeßte chnik 10 The EV in the display will blink to remind you that the standard factory calibration has been changed. Input of the correction in 1/3-stops in the range of ± 3 EV. For cancelling the correction value, remove the battery from the compartment for a moment and then put it back again. In case of over-exposure a po[...]

  • Page 11

    GOSSEN Foto- und Lichtmeßte chnik 11 – Enter the "seconds" of the desired length of time. Confirm by pressing and holding the function button until the OK-signal will sound. The timer will now be in the Start/ Stop function. – Push the key M to start the timer. The display will show the remaining time of the count-down. In addition t[...]

  • Page 12

    GOSSEN Foto- und Lichtmeßte chnik 12 2.6 W atch/Alarm clock W A TCH – Setting the time – Use the function button to select the function WATCH and hold the key down until the OK-signal will sound. 12/24 will flash. – With the function button select either 12 hours (AM/PM) – 24 hour display. – Confirm with the function button. The read-out[...]

  • Page 13

    GOSSEN Foto- und Lichtmeßte chnik 13 ALARM CLOCK – Use function button to enter the function "ALARM CLOCK" and hold it pressed down until the OK-signal will sound. The time of the alarm clock is set in the same way as the watch. – Hold the function button until the OK-signal sounds. – The alarm is activated or deactivated with the [...]

  • Page 14

    GOSSEN Foto- und Lichtmeßte chnik 14 2.7.1 Min./Max. temperatures When repeatedly pressing the measuring key, the minimum (Lo) and maximum (Hi) temperature values will be indicated. The minimum and maximum values indicated are those that have been measured since the last cancellation operation. The min. and max. temperatu re values stored in memor[...]

  • Page 15

    GOSSEN Foto- und Lichtmeßte chnik 15 4 T echnical d ata Exposure meter Measuring modes Ambient light Incident light method Reflected light method Contrast measurem. Light sensor sbc photo diode Measuring range (when ISO 100/21°) EV 0 to 18 Shutter speeds 1/2000 s to 4 min Apertures 1 to 32 Calibration adjustments ± 3.0 Film speeds ISO 6 to 3200 [...]

  • Page 16

    Printed in German y • Subject without notice GOSSEN Foto- und Lichtmeßt echnik GmbH Thomas-Mann-S tr . 16-20 D-90471 Nürnberg Phone: +49 91 1 / 8602-181 Fax: +49 91 1 / 8602-142 http://www .gossen-photo.de Battery 1 x 3 V Lithium battery CR 2032 Operating temp. –10 °C ... 60 °C Dimensions 75 x 50 x 23 mm Weight 40 g incl. battery Accessorie[...]