Goodmans Package Heat Pump Units manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodmans Package Heat Pump Units, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodmans Package Heat Pump Units one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodmans Package Heat Pump Units. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodmans Package Heat Pump Units should contain:
- informations concerning technical data of Goodmans Package Heat Pump Units
- name of the manufacturer and a year of construction of the Goodmans Package Heat Pump Units item
- rules of operation, control and maintenance of the Goodmans Package Heat Pump Units item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodmans Package Heat Pump Units alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodmans Package Heat Pump Units, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodmans service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodmans Package Heat Pump Units.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodmans Package Heat Pump Units item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MAN[...]

  • Page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure[...]

  • Page 3

    PRODUCT IDENTIFICA TION 3 GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”)[...]

  • Page 4

    4 PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible[...]

  • Page 5

    PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: roof top in- stallations) [...]

  • Page 6

    6 PRODUCT DESIGN ELECTRICAL DA T A (*Blower Only , Heat Mode) All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum ov[...]

  • Page 7

    PRODUCT DIMENSIONS 7 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T O PENI NGS ) A 14 . 0 00 B GPH13[24-60]H41** Ch as s i s M o d el A B GP H13 24H 41* * 22 . 0 00 29 . 932 GP H13 30H 41* * 22 . 0 00 29 . 932 GP H13 36H 41* * 24 . 0 00 34 . 932 GP H13 42H 41* * 24 . 0 00 34 . 932 GP H13 48H 41* * 24 . 0 [...]

  • Page 8

    P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]H41AB GPH1336H41AC (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive[...]

  • Page 9

    P ACKAGE HEA T PUMP SPECIFICA TIONS 9 (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger [...]

  • Page 10

    ACCESSORIES 10 P a rt Nu m b e r De s cr i p t i on O T 18- 60 A O ut door T her mosta t Ki t w /Loc kout S tat O T /EHR18-60 Em e r genc y Heat Rel ay K i t HKR E l ectr ic H eat Ki t PCCP101- 103 Roof C ur b PCP 101- 103 Dow nflow Pl enum Ki t PCP 101- 103R8 Dow nflow Pl enum Ki t w / R - 8 I ns ulati on G PCED101- 103 Dow nflow Ec onomi zer for [...]

  • Page 11

    BLOWER PERFORMANCE DA T A 11 Dry Coil Data NOTES: 1. Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 2. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx. 0.08” H 2 O. 4. Reduce airflow by 2% for 208V oper[...]

  • Page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P U T B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPERAT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800[...]

  • Page 13

    13 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41* * EX PAN DE D P ER F O R M ANC E D ATA COOLIN G OP E RA TION De sign S ub c ool i ng , 1 2 ±3 °F @ t he li q ui d ac c es s f i tt ing c on nec tio n AHRI 9 5 t e st c o ndi ti ons. Des i gn Superhe a t 8 ±3 °F @ the c o mp r e s s or s uc tion a c cess fit ting c onne c t i on. O[...]

  • Page 14

    14 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41** EX PAN DE D P ER FO R M ANC E D ATA COOLIN G OP E RATION De sign Subc ool i ng , 12 ±3 °F @ the l i q ui d a cces s f i tt i ng connecti o n AHRI 95 t e st c o nd i ti ons. Des i g n Supe rhea t 8 ±3 °F @ the c om pr e s s or suction acc e ss fit ting c onne ct i on. O utdoo r Am[...]

  • Page 15

    15 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e [...]

  • Page 16

    16 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e [...]

  • Page 17

    17 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L : GP H 1336H41* * E XP A ND E D PE RF ORMA N CE DA TA C OOL IN G OP E RATION De s i gn Subc oo l i n g , 1 2 ±3 °F @ the liqui d ac c es s f i tt ing c o nnec ti on AHRI 9 5 t es t c o ndi ti o ns. Des i gn S up erhea t 8 ±3 °F @ t he c om p r e s s o r suc t i o n a cce ss fi t ti n g co n n e[...]

  • Page 18

    18 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L: GP H 1336H41** E XP A ND ED PE RF ORM A N CE DA T A COOL IN G OP E RATI O N De sign Subc o ol i ng , 12±3 °F @ the l i q ui d ac c es s f it t i n g conne c tio n AHRI 9 5 t es t c o ndi tion s. Des i g n Supe r h e a t 8 ±3 °F @ t he c om pr e ss o r su c t i o n a cce ss f i t t i n g co n n[...]

  • Page 19

    19 COOLING PERFORMANCE DA T A GPH1342H41** MOD EL: GP H 1342 H41** EX PAN DE D P ER F O R M ANC E D ATA CO O LI N G OP E RA T I O N De s ign S ub c oo ling , 1 2± 3 °F @ t he li qu id a c ce s s f i t t i ng c on ne ct ion A R I 9 5 t e s t con d it ion s . De s ig n S u pe rh e a t 8 ±3 °F @ t he c o mp re s s or s u ction a c ces s f i tt i n[...]

  • Page 20

    20 COOLING PERFORMANCE DA T A GPH1342H41** MOD E L : GP H 1342H41** EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT I ON De sig n Subc oo l i ng , 12 ±3 ° F @ the l i q ui d ac c es s f i tt i n g c onnec ti on AHRI 95 t es t c o ndi tio ns. Des i gn S uperhea t 8 ±3 °F @ the compr e ss o r suc t i o n a cce ss f i t t i n g co n n ect [...]

  • Page 21

    21 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne[...]

  • Page 22

    22 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne[...]

  • Page 23

    23 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41 * * EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT IO N D esi g n Su b co o l i n g , 12 ±3 ° F @ th e l iq u i d acc ess f itt in g co n n ec ti o n A H R I 95 t est c ond i t i o n s. D esi g n Su p er h ea t 8 ±3 ° F @ th e co m p r ess o r su c t i o n a cce ss f i t[...]

  • Page 24

    24 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41** E X P A ND ED PE RF ORM A N CE DA T A C O OL I NG OP ER AT IO N D esi g n Su b co o l i n g, 12 ±3 ° F @ t h e l iq u i d ac c ess f itt in g co n n ec ti o n A H R I 95 t est c o n d i ti o n s. D es i g n Su p er h ea t 8 ±3 ° F @ t h e co m p r e ss o r su c t i o n a cc e s[...]

  • Page 25

    P ACKAGE HEA T PUMP SPECIFICA TIONS 25 GPH13[24-36]H41** E X PAN D ED PE RFO R M AN CE DAT A MOD E L : G P H 1324H 41* H E AT ING OPE RA TION O utdoor Am bi e nt Te m pera tur e 65 60 55 50 47 45 40 35 30 25 20 17 1 5 1 0 5 0 - 5 -10 M B h 2 7 . 72 6 . 22 4 . 62 3 . 02 2 . 02 1 . 31 9 . 81 8 . 31 7 . 41 6 . 11 4 . 8 1 4 . 0 1 3 . 5 1 2 . 1 1 0 . 7 [...]

  • Page 26

    P ACKAGE HEA T PUMP SPECIFICA TIONS 26 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatu[...]

  • Page 27

    WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1324, 30, 42H[...]

  • Page 28

    28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1360H41BB 2 3[...]