Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS should contain:
- informations concerning technical data of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS
- name of the manufacturer and a year of construction of the Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS item
- rules of operation, control and maintenance of the Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg GMS8 33-3/8 GAS FURNACE UNITS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    RT6621031r2 November 2013 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. • Refer to Service Manual RS6612006 for troubleshooting information. • Refer to[...]

  • Page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WA RNI N G WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Fail[...]

  • Page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GMS80403A*BB GMS80603A*BB GMS80604B*BB GMS80804B*BB GMS80805C*BB GMS81005C*BB GMS81205D*BA The United States Environmental Protection Agenc[...]

  • Page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system.[...]

  • Page 5

    5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6 Gas Valve 7 Rollout Limit 8 Junction Box ? Pressur e Sw itch Tubul ar Heat E xchan g er Fl ue P i pe Co nn e c tion Ga s Li ne E nt ra nce (Alt e rnat e ) Ind uced Dr aft Blow er Ga s Li ne Ent[...]

  • Page 6

    PRODUCT DIMENSIONS 6 GMS8 A lt. Ga s Inlet H i g h Vol t ag e In le t L o w V oltage A lt. Ga s Inlet A lt. High V o lt ag e Alt. LowV oltage MOD E L A B G M S 8 04 03 A ** * G M S 8 06 03 A ** * G M S 8 06 04 B * ** G M S 8 08 04 B * ** G M S 8 08 05 C * ** G M S 8 10 05 C * ** G M S 8 12 05 D * ** G M S814 05D N ** 24 - 1/ 2 23 21 19 - 1/ 2 14 12[...]

  • Page 7

    7 PRODUCT DIMENSIONS GMS8[040-100]BB GMS81205D*BA GMS81405DNCC For installations in Canada, the GMS furnaces are certifed only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Mo d el T r i p P o in t ID Blo w e r P ress u re Sw i tch ID Blo w e r P ress u re Sw i tch Pa rt # G M S 804 03A * B B - 0. 70 B 1370 158 G M[...]

  • Page 8

    8 PRODUCT DESIGN Thermost ats: Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters Cabi net Wi d t h (i n. ) Nominal Filter Siz e (in. ) A pprox . Fl ow A rea (i n 2 [...]

  • Page 9

    FURNACE SPECIFICA TIONS 9 1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. 2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for alti[...]

  • Page 10

    BLOWER PERFORMANCE SPECIFICA TIONS 10 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO [...]

  • Page 11

    11 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 90 1 10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OU T P UT B T U / HR x 10 00 BTU OUTPUT v s TEMPERA TURE RISE CHAR T TE M PE R A TU R E R ISE 600 CF M 700 900 1000 1 100 1200 1400 1600 1800 2000 2200 24 00 CF M F O RMULAS BTU OUTPUT = CFM x 1.08 x R ISE RIS E = BT U O UT P UT 800[...]

  • Page 12

    12 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. GMS8 CAP BK ([...]

  • Page 13

    13 SCHEMA TICS HIGH VOL T A GE! DISCONNECT AL L POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . M UL TIPL E POWER SO URCES MA Y BE P RESENT . F AI LURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL INJURY OR DEA TH. TYPICAL SCHEMATIC GMS8 * MODEL FURNACES WR 50T55-289 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not al[...]