Goodman Mfg GHS8 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg GHS8, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg GHS8 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg GHS8. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodman Mfg GHS8 should contain:
- informations concerning technical data of Goodman Mfg GHS8
- name of the manufacturer and a year of construction of the Goodman Mfg GHS8 item
- rules of operation, control and maintenance of the Goodman Mfg GHS8 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg GHS8 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg GHS8, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg GHS8.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg GHS8 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    GDS8 & GHS8 33-3/8" 80% Gas Furnace Unit s • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3. RT6622011 S[...]

  • Page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician&qu[...]

  • Page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. * These models available in Low NOx The United States Environmental Protection Agency (“EPA”) has issued various regulations re- gardin[...]

  • Page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system.[...]

  • Page 5

    5 PRODUCT DIMENSIONS MO D EL A B G H S 80 453 A XC* 14 1/ 2 " 1 2 1/ 2" GH S 80 7 04 B X C * 17 1 / 2 " 1 6" GH S 80 9 05 C X C * 21" 1 9 1/ 2" MO D EL A B G D S 80 453 A XC* G D S 80 703 A XC* GD S 80 9 04 B X C * 17 1 / 2 " 1 6" GD S 81 1 55 C X C * 21" 1 9 1/ 2" 14 1/ 2 " 1 2 1/ 2"[...]

  • Page 6

    6 PRODUCT DESIGN GHS8 For installations in Canada, the GHS furances are certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GHS 804 53A XC* 2 GHS 807 04B XC* 2 GHS 809 05C XC* 2 R O LL O U T L IMI T SW IT C H ES P art N u m b er 0130F00038 O p en Se t[...]

  • Page 7

    7 PRODUCT DESIGN GDS8 Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GDS 804 53A XC* 2 GDS 807 03A XC* 2 GDS 809 04B XC* 2 GDS 811 55C XC* 2 R O LL O U T L IMI T SW IT C H ES M od e l P a r t N o . O pe ns * G DS804 53A X C * B13 70142 - 0. 60 G DS807 03A X C * B1 37158 - 0. 70 G DS809 04B X C * B13 70142 - 0.60 G DS811 55C X C * B1 37158 [...]

  • Page 8

    8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GHS8 furnaces, in horizontal applications and for the GDS8 for downflow applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existin[...]

  • Page 9

    9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow [...]

  • Page 10

    10 PRODUCT DESIGN Counterflow Filters "A" Min Return Air Opti onal Ac ce ss Door This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace will accommodate the following filter sizes depending on cabinet size: Refer to Minimum Filter Area tables to determine filter area requirement. [...]

  • Page 11

    FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above[...]

  • Page 12

    FURNACE SPECIFICA TIONS Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above 20[...]

  • Page 13

    13 BLOWER PERFORMANCE SPECIFICA TIONS GHS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION [...]

  • Page 14

    BLOWER PERFORMANCE SPECIFICA TIONS 14 GDS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION I[...]

  • Page 15

    15 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 9 0 11 0 12 0 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/H R x 10 00 BTU OUTPUT vs T EM PERATURE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 1600 1800 2000 220 0 240 0 C F M FORMULAS BTU OUT PUT = CFM x 1. 08 x RI SE RISE = BTU O UTP UT 1.0 8 ÷ CF M [...]

  • Page 16

    16 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH . G*S8 B O X[...]