GarrettCom IPS42 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of GarrettCom IPS42, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GarrettCom IPS42 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of GarrettCom IPS42. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of GarrettCom IPS42 should contain:
- informations concerning technical data of GarrettCom IPS42
- name of the manufacturer and a year of construction of the GarrettCom IPS42 item
- rules of operation, control and maintenance of the GarrettCom IPS42 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GarrettCom IPS42 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GarrettCom IPS42, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GarrettCom service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GarrettCom IPS42.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the GarrettCom IPS42 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    www Garre t t Com com .. www Garre t t Com com .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com Magnum IPS42 Internal Power Supply for Edge Switch Family Installation and User Guide[...]

  • Page 2

    IPS42 Internal Power Supply Installation and User Gui de (11/09) i www Garre t t Com com .. Magnum ™ IPS42 Internal Power Supply for Edge Switch Family Installation and User Guide Part #: 84-00181Z Rev. B Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Co[...]

  • Page 3

    IPS42 Internal Power Supply Installation and User Gui de (11/09) ii www Garre t t Com com .. Important: The Magnum IPS42 Series Intern al Power Supply for Edge Switches contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If pr oblems are experienced with Magnum IPS42 Internal Po[...]

  • Page 4

    IPS42 Internal Power Supply Installation and User Gui de (11/09) iii www Garre t t Com com .. Federal Communications Commission Radio Frequency Interferen ce Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may ca[...]

  • Page 5

    IPS42 Internal Power Supply Installation and User Gui de (11/09) iv www Garre t t Com com .. Electrical Safety requirements: 1. This product is to be installe d Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets , or the like). 2. 48VDC products shall be installed with a readily accessible disconnect device in the buildi[...]

  • Page 6

    IPS42 Internal Power Supply Installation and User Gui de (11/09) v www Garre t t Com com .. Contacting GarrettCom, Inc Please use the mailing address, phone, fax num bers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support[...]

  • Page 7

    IPS42 Internal Power Supply Installation and User Gui de (11/09) vi www Garre t t Com com .. TABLE OF CONTENTS Page 1.0  SPECIFICATIONS ............................................................................... 1  1.1  Technical Speci fications ...................................................................... 1  1.2  Summa [...]

  • Page 8

    IPS42 Internal Power Supply Installation and User Gui de (11/09) vii www Garre t t Com com .. 4.2  When Calling for Assistance ............................................................. 24  4.3  Return Material Authori zation (RMA) Procedure ............................. 25  4.4  Shipping and Packagi ng Information ...............[...]

  • Page 9

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 1 www Garre t t Com com .. 1.0 SPECIFICATIONS 1.1 Technical Specifications AC/DC Power Supply (Model IPS42-AC/DC): Power Input: DC: 100-250 VDC AC: 100-250 VAC, 47 to 63 Hz, auto ranging Surge Rating: IEC 61000-4-3, Class 3/4 (4KV for DC) Std. Recessed Terminal Bl ock: “-, GND, +”[...]

  • Page 10

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 2 www Garre t t Com com .. AC Power Supply (Model IPS42-AC) AC Power Connector: standard IEC 320 male, recessed Power Input: 100-250 VAC, 47 to 63 Hz, auto ranging Power Consumption: 10 Watts ty pical for a 4+2 port fiber model Mechanical Specifications: Enclosure: Rugged sheet metal [...]

  • Page 11

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 3 www Garre t t Com com .. Cooling Method: All IPS42 models feature convection cooling for temperature un-controlled locations. All models have closed cases to withstand dirt and us e special thermal techniques to transfer heat to the outside of the case for cooling. ALARM RELAY Termi[...]

  • Page 12

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 4 www Garre t t Com com .. Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions m eets FCC Part 15 Class A IEC 61850 EMC and Operating Conditi ons Class C Power Substations IEEE 1613 Env. Standard for Electrical Power Substations NEBS L3 and ETSI complia[...]

  • Page 13

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 5 www Garre t t Com com .. 1.2 Summary of models and descri ptions for IP S42 Se ries: IPS42-AC/DC: Internal Power Supply chassis fo r use with any ES42H or ES42P Series Edge Switch. Require s simultaneous ordering of an ES42 (without external power supply) as a separate line item. Ra[...]

  • Page 14

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 6 www Garre t t Com com .. IPS42-48VDC-DualSRC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line ite m. Rated 44 to 57 VDC, Dual Source. Power input via recess[...]

  • Page 15

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 7 www Garre t t Com com .. IPS42-AC: Internal Power Supply chassis fo r use with any ES42H or ES42P Series Edge Switch. Require s simultaneous ordering of an ES42 (without external power supply) as a separate line item. Standard worldwide AC power input via standard IEC320 recessed ma[...]

  • Page 16

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 8 www Garre t t Com com .. 2.0 INTRODUCTION 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage that y ou believe occurred during shipment or delivery. Inspect the c[...]

  • Page 17

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 9 www Garre t t Com com .. Remove the Magnum IPS42 Series Internal Power Supply from the shipping container. Be sure to keep the shipping contai ner should you need to ship the unit at a later date. In the event there are items missing or da maged contact your supplier. If you need to[...]

  • Page 18

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 10 www Garre t t Com com .. 2.3 Features and Benefits  100 to 250V range, 4KV surge protected AC/DC models are rated at 100-250V with a maximum of 4KV surge suppression. The only High Voltage AC/DC Ethernet unit on the market that is UL Listed for user safety.  Dual-Source power[...]

  • Page 19

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 11 www Garre t t Com com .. 3.0 INSTALLATION This section describes the installati on of the Magnum IPS42 Internal Power Supply, including location, mounting, power cord and media connections. 3.1 Locating the IPS42 The compact and lightweight design of th e Magnum IPS42 Series allows[...]

  • Page 20

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 12 www Garre t t Com com .. Installation of the Magnum IPS42 Series of products is a simple procedure. The installation location is dependent upon the physi cal layout of the Ethernet network and associated cabling. Make sure the unit is ins talled in a location that is easily accessi[...]

  • Page 21

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 13 www Garre t t Com com .. Note: The metal brackets supplied hold the back of the IPS42 unit out from the panel or wall behind it, creating a rear space of ab out ¼ inch or 1cm. This allows air circulation and cooling of the rear p art of the case. For best cooling of the IPS42 S er[...]

  • Page 22

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 14 www Garre t t Com com .. The unit is mounted using the brackets as s hown in the illustration above. The spacing for the mounting screws into the supporting wa ll or panel is a rectangle 15.49 x 12.89 cm (6.10 x 5.075 inches) center-to-center.[...]

  • Page 23

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 15 www Garre t t Com com .. 3.1.2 DIN-Rail mounting option The Magnum IPS42 Power Supply, designed for use in “Factory Floor” Industrial Ethernet environments, is available for DIN-Rail mounting in an enclosure having DIN Rails. A Magnum IPS42 is shown with the DIN-RAIL-MC2 bracke[...]

  • Page 24

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 16 www Garre t t Com com .. 3.2 Power Cord Installation For IPS42-DC w/Dual Source and AC/D C models that do not have the power cord installed at the factory, follow the pr ocedures as described below. For detailed technical specifications, refer to Section 1.1 of this User Guide. The[...]

  • Page 25

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 17 www Garre t t Com com .. Use the Power Cord installation kit (items for Dual Source shown in Fig. 3.2b) to connect the power cord to the unit. Note: For Single Source models, the kit will include a single opening power cord cover and one protective bushing. a. Slide the power cord [...]

  • Page 26

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 18 www Garre t t Com com .. For Dual Source models, positi ons A and B will be used. For Single Source models, only position A will be used. NOTE: None of the conductor can be exposed after secured in the terminal block. c. Install the protective bushings and secure to the power cord [...]

  • Page 27

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 19 www Garre t t Com com .. B R O W N o r B L A C K ( + ) BLUE or WHITE (-) G R N / Y L W o r G R E EN ( G N D ) (+) (-) (GND)[...]

  • Page 28

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 20 www Garre t t Com com .. 3.3 Hardware operated Alarm Contact The two screw Alarm Contacts feature, standard on Magnum IPS42-Series, provides Normally Closed (NC) contacts to which the user can attach one set of status monitoring wires at the green terminal block. The NC Alarm Conta[...]

  • Page 29

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 21 www Garre t t Com com .. 1. Four-position terminal block (positi ons 1 & 2) as shown in Figure 4.4a 2. The Alarm Relay contact connected to the two terminals (1, 2) is hardware operated. 3. By default it is NC (normally closed). It will open if there is any loss of power to the[...]

  • Page 30

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 22 www Garre t t Com com .. 4.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the appli cable chapter of this manual. Also check to make sure that the vari ous components of the network ar[...]

  • Page 31

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 23 www Garre t t Com com .. 4. Make sure that an AC power cord is properly attached to each Magnum IPS42 Series unit. Be certain that the AC power cord is plugged into a functioning and appropriate electrical ou tlet. Use the PWR LEDs to verify each unit is receiving power. 5. If the [...]

  • Page 32

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 24 www Garre t t Com com .. 4.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations/Environment when the problem occurs; [...]

  • Page 33

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 25 www Garre t t Com com .. 4.3 Return Material Auth oriz ation (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization (RMA) number. To obtain an RMA number, please use this URL - https://rma.garrettcom.com/r ma/rma_request_noaccount. php to fill[...]

  • Page 34

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 26 www Garre t t Com com .. GarrettCom will carefully test and evaluate a ll returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for[...]

  • Page 35

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 27 www Garre t t Com com .. CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static sh ock damage to the unit. 2. Clearly mark the Return Materi al Authorization (RMA) number on the outside of the shipping container.[...]

  • Page 36

    IPS42 Internal Power Supply Installation and User Gui de (11/09) 28 www Garre t t Com com .. APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repa ir or, at[...]