The rules should oblige the seller to give the purchaser an operating instrucion of Friedrich ZQ10 A10B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Friedrich ZQ10 A10B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Friedrich ZQ10 A10B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Friedrich ZQ10 A10B should contain:
- informations concerning technical data of Friedrich ZQ10 A10B
- name of the manufacturer and a year of construction of the Friedrich ZQ10 A10B item
- rules of operation, control and maintenance of the Friedrich ZQ10 A10B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Friedrich ZQ10 A10B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Friedrich ZQ10 A10B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Friedrich service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Friedrich ZQ10 A10B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Friedrich ZQ10 A10B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Room Air Conditioner Ser vice and P ar ts Man ual ZStar TM ZQ10 (03/01)[...]

  • Page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES......................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1[...]

  • Page 3

    —3— 1.3 SPECIFICA TIONS POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (Btu/W.h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP. CONTROL AIR DIRECTION CONTROL CONSTRUCTION PROTECTOR COMPRESSOR FAN MOTOR PO[...]

  • Page 4

    1.4 FEA TURES • Designed for cooling only. • Powerful and whisper cooling. • Slide-in and slide-out chassis for the simple installation and service. • Side air-intake, side cooled-air discharge. 1.5 CONTR OL LOCA TIONS 1.5.1 CONTROL ONL Y MODEL • VENTILATION The ventilation lever must be in the CLOSE position in order to maintain the best[...]

  • Page 5

    — 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the INLET GRILLE downward and remove the air filter. 2. Remove the screw which fastens the FRONT GRILLE. 3. Pull the FRONT GRILLE from the right side. 4. Remove the FRONT GRILLE. 5. Re-install the component by referring to the above removal procedure. (See figure 1) 2.1.2 CABINET 1. After [...]

  • Page 6

    — 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND BLO WER 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator. 7. Move the ev[...]

  • Page 7

    2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the terminal cover. (See Figure 7) 4. Remove all the leads from the overload protector. 5. Remove the overload protector. 6. Re-install the component by referring to the removal procedure,[...]

  • Page 8

    — 8 — 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Open the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the control box. 4. Disconnect the 2 receptacles. 5. Remove a screw which fastens the clip cord. (See Figure 10) 6. Remove the power cord. 7. Re-install the component by referring t[...]

  • Page 9

    2.4 REFRIGERA TING CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the 3 screws which fasten the brace.(Refer to section 2.2.1) 3. Remove the screw which fastens the cover cond. 4. Remove the 5 screws which fasten the condenser and shroud. 5. After discharging the refrigerant completely, unbraze the interconnecting t[...]

  • Page 10

    — 10 — — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after servicing the system. 2. Af[...]

  • Page 11

    — 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MAN[...]

  • Page 12

    — 12 — 3. INST ALLA TION 3.1 INST ALLA TION HARD W ARE Type C (5) Type A (13) Bolt (2) Nut (2) Type B (3) Foam top window gasket Window sash seal Window locking bracket Left frame curtain Frame guide(2) Sill support(2) Right frame curtain 3.2 SELECT THE BEST LOCA TION Step 1. To prevent vibration and noise, make sure the unit is installed secur[...]

  • Page 13

    — 13 — 3.3 WINDO W REQUIREMENTS Step 1. These instructions are for a standard double hung window. You will need to modify them for other types of windows. Step 2. The air conditioner can be installed without the frame curtain if needed to fit in a narrow window. See the window opening dimensions to the right. Step 3. All supporting parts must b[...]

  • Page 14

    ✓ Remove the 2 shipping screws from the back of the case. ✓ Remove the 2 screws on each side of the case. Keep these for later use. ✓ Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. 3.6 BEFORE INST ALLA TION... ✓ Cut the window sash seal to the proper length. Peel off the b[...]

  • Page 15

    Step 1. Open the window and mark the centerline of the window stool (or desired air conditioner location). Step 2. Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool Step 3. Pull the window down behind the top mounting rail NOTE: Do not shut the window so tightly that movement[...]

  • Page 16

    Step 1. Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Step 2. Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown. Step 3. Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of t[...]

  • Page 17

    — 17 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 525mm(20 11 / 16 ") 470mm(18 1 / 2 ") 353mm(13 7 / 8 ") 250mm(10")[...]

  • Page 18

    — 18 — CAPILLARY TUBE COMPRESSOR BLOWER EV APORA TOR COIL : REFRIGERANT FLOW CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM The following is a brief description of the important components and their function in what is called the refrigeration system. Reference should made to figure 17 to follow the refrigerating cycle and the flow of the refriger[...]

  • Page 19

    — 19 — 4.3 TROUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect. The other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling is ineff ective . Ineffective Cool[...]

  • Page 20

    — 20 — Fails to Start Check of circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check of control switch. Only fan fails to start. Improper wiring Defect of fan motor capacitor Resistance irregular motor ( ). Insulation irregular motor ( ). Replacement of fan motor Regular but fails to start Replacement of compressor (Locking o[...]

  • Page 21

    — 21 — — 21 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if none defective. Connect wire. Refer to wiring diagram for terminal i[...]

  • Page 22

    — 22 — COMPLAINT CAUSE REMEDY If cracked, out of balance, or partially missing, replace it. If cracked, out of balance, or partially missing, replace it. Tighten it. If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor. Check voltage. See the limits [...]

  • Page 23

    — 23 — COMPLAINT CAUSE REMEDY If not running, determine the cause. Replace if required. Remove the cabinet, inspect the interior surface of the condenser. If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before re-assembling. If the condenser fins are closed over a large area on the coi[...]

  • Page 24

    — 24 — 5. SCHEMA TIC DIA GRAM • CIRCUIT DIA GRAM • MODEL : ZQ10A10B WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMISTOR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR(BR) SYNC MOTO R R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .W .B ASM RY -SYNC 250V/T2A (115V/T2A) TRANS FORMER ZNR RY -COMP MAIN P .W .B ASM BK[...]

  • Page 25

    —25— 6. EXPLODED VIEW 16 34 62 63 49 53 52 51 50 49 48 6 56 55 61 57 60 59 58 25 29 28 31 26 22 23 17 18 19 27 20 29 30 3 2 10 9 7 1 21 24 37 36 43 42 47 46 41 40 44 15 14 13 12 11 8 35 32 45 38 E A C D B 5 4 39 33 54[...]

  • Page 26

    — 26 — 7. REPLA CEMENT P AR TS LIST • MODEL: ZQ10A10B PART NO. DESCRIPTION REMARK 1 1 1 1 1 2 1 3 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 1 1 2 1 1 1 1 1 R R R R R R R R R N N R R R R R R R R R R R R N N R R R R R R R R R R ZQ10A10B LOCATION NO . FRIEDRICH PART NO. Q'TY PER SET 673-060-02 673-044-02 673-061-01 673-043-02 673-062-01 673-062[...]

  • Page 27

    — 27 — PART NO. DESCRIPTION REMARK ZQ10A10B LOCATION NO . FRIEDRICH PART NO. Q'TY PER SET C CONTROL BOX ASSY 4995A20118N 1 R 35 673-054-01 CONTROL BOX, SINGLE 4994A10006B 1 R 36 673-055-01 CONTROL PANEL ASSY 3721A20037B 1 R 37 673-041-03 KNOB ASSY 4941A30011A 2 R 38 CAPACITOR 0CZZ20001V 1 R 39 673-006-00 CAPACITOR CLAMP 4H00442N 1 R 40 POW[...]

  • Page 28

    ZQ10 (03/01) Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20038V Use F actor y Cer tified P ar ts...[...]