Friedrich 920-087-04 (3-05) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Friedrich 920-087-04 (3-05), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Friedrich 920-087-04 (3-05) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Friedrich 920-087-04 (3-05). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Friedrich 920-087-04 (3-05) should contain:
- informations concerning technical data of Friedrich 920-087-04 (3-05)
- name of the manufacturer and a year of construction of the Friedrich 920-087-04 (3-05) item
- rules of operation, control and maintenance of the Friedrich 920-087-04 (3-05) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Friedrich 920-087-04 (3-05) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Friedrich 920-087-04 (3-05), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Friedrich service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Friedrich 920-087-04 (3-05).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Friedrich 920-087-04 (3-05) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    920-087-04 (3-05) PT A C P A CKAGED TERMINAL AIR CON DI TION ERS & HEA T PUMPS Standard Contr ol Remo te Thermostat Seacoast Pr ot ected INS T ALL A TION & OPER A TION GUIDE[...]

  • Page 2

    2 920-087-04 (3-05) Unit C ompo nents ............................................................................................................... ................................................................................ 2 Mode l Number C ode .................................................................................................[...]

  • Page 3

    3 920-087-04 (3-05) Thank y ou for your decision to pu rchase the newly designed F r iedrich Packaged T erminal A ir Conditioner (P T AC ). We are con fi den t that you will fi nd this unit a q uiet and e f fi cien t example o f F riedr ich reliability . This Inst allation and O perati on Manual ha s been designed to in sure maximum satisfaction[...]

  • Page 4

    4 920-087-04 (3-05) P TAC Installat ion Recommendations For proper P TAC unit perf ormance and ma x imum operat ing life please refer to the minimum installation clearances below: The abov e suggestions are for ref erence only and do not represent all poss ible installations. P lease contact the fac tor y for information regarding affec ts of other[...]

  • Page 5

    5 920-087-04 (3-05) Fried rich Digital Control Features The new F rie dric h digital PT A C has state of the ar t features to improv e guest co mfor t, indoor air qualit y and c onser ve energy . Through the use of speci fi cally designed c ontrol sof t ware for t he PT AC indust r y Friedr ich has acc omplishe d what other Manufactur- er ’ s ha[...]

  • Page 6

    6 920-087-04 (3-05) Fried rich Digital Contr ol Features Continued Instant Heat Heat Pump Mode Heat pump models w ill automatic ally run t he electr ic heater to quic kly bring t he room up to temper ature when initially ener gize d, t he n r et ur n t o h e at p um p m o de . T h i s e n su r e s t h at t h e r o o m i s brought up to temper ature[...]

  • Page 7

    7 920-087-04 (3-05) Inst allat ion Ins t ruc t ions PX DR 10 Dr ain K it Internal Drain ( optiona l f or new construct ion ) NOTE: If installing an inter nal drain, you MUST install a drain kit on the wall sleeve be fore the wall sleeve is installed. 1 . Refer to Figure 3 below and locate the drain within the " Primar y " area for best dr[...]

  • Page 8

    8 920-087-04 (3-05) External Drain (f o r n e w c o n s t r u c t i o n o r u n i t r e p l a c e m e n t ) When using an exter nal drain system, the condensate is removed th rough either of t wo drain holes on the back of t he wall sleev e . Select the drain hole whic h best meets your drainage situation and install the drain kit . Seal of f the o[...]

  • Page 9

    9 920-087-04 (3-05) W a ll Slee ve In stal la tion I nstructio ns ( PDX WS ) NOTE: Insure that the unit is only installe d in a wall str uct urally adequate to suppor t t he unit including the sleeve, chassis and acces sorie s. If the slee ve p rojects more than 8 " int o the room, a sub base or other means of suppor t MUST be used. Please rea[...]

  • Page 10

    10 920-087-04 (3-05) 3 . Drill t wo 3 / 16" holes through each side of the sleeve approximat ely 4" from top and 4" from bottom of sleeve . Screw four #10 x 1 " screws (included) or appropriate fasteners for your installation, through the holes i n the sides of the wall sle ev e. 4 . Apply sealant around the wall sleeve where it[...]

  • Page 11

    11 920-087-04 (3-05) If the wall is thicker than allowed in the notes in Figure 6, a sheet met al wall sleeve e x ten sion and fl ashing M UST be used. Installat ion Inst ruct ions for t he PX WE – 4 " Wall Sleeve E x tension The following points M UST be c onsidered when inst alling a wall sleev e extension: 1 P r ov is i o n m u s t b e m[...]

  • Page 12

    12 920-087-04 (3-05) Plastic handles Plastic grommets 1 . Remov e the c enter suppor t and weatherb oard if still in stalled in the sleeve . 2. Inser t si x plastic grommets into the grille openings f rom the outside of the gr ille as shown in Figure 9. 3. Inser t t wo # 8 x 3 / 8 " sheet metal screws (provided ) in the top t wo outside edge p[...]

  • Page 13

    13 920-087-04 (3-05) A . Ele ctric al Ra ti ng T a bl es All 230 / 208 volt units are equipped with power cords. Se e Appendi x B on pag e 19 for wir ing in struc tions on 265V unit s. NOTE: Use Copper C onductor s ONL Y . Wire sizes are per NEC, check local c odes for over seas ap pli ca tions. WIRE SIZE U s e O N L Y w i r i n g s i z e r e c o m[...]

  • Page 14

    14 920-087-04 (3-05) Sec tion III – Chas sis Inst allat ion 1 . Remov e the weatherboard and c enter suppor t from the sleeve (if still in plac e). Be sure an outdoor gr ille is at tache d. Check to be sure the wall sleeve, ex tension ( if used), grille, and d rain kit are inst alled properl y before chassis inst allation . 2. Remove the front co[...]

  • Page 15

    15 920-087-04 (3-05) 4. Ce nter the cha ssis in the pre-instal led slee ve and care ful ly push the chassis unt il the chas sis fl ange and gas ke t c o nt a c t the slee ve fl ange. If a remote t hermost at is to be inst alled, proc eed to page 18, Step 1 . For a 265 V unit, pr oceed to A ppendi x A , Step 1. NO TE: If the un it is moun ted fl [...]

  • Page 16

    16 920-087-04 (3-05) Digital Control User Inpu t Confi gu ra tio n The adjustable c ontrol dip switches are loc ated at the lower lef t hand po r tion of the digit al Smar t Center . The inputs are onl y visible and acc essible with t he front cover remov ed f rom the PT A C. Dip Sw itch Set t ing 1 ) Electronic Te mperatur e Limiting – Switches[...]

  • Page 17

    17 920-087-04 (3-05) Digital Contr ol Operation Te m p e r a t u r e D i s p l a y The Friedrich digit al PT AC is shipped from t he factor y to display the desired room temperature on the LED readout. The uni t can be confi gured to display the room temperature b y simultaneously pre ssing the ‘ Cool ’ and ‘ High Fa n ’ but tons for three[...]

  • Page 18

    18 920-087-04 (3-05) R Y W B GL GH C D1 D2 F1 F2 JP1 12 34 56 78 ON DIP Re mote T hermostat and Low V oltag e Cont rol C onnections T o c ontro l the uni t with a wa ll mo unte d the rmosta t fol low the steps below : 1 ) W ith the front c over remo ved locate the low volt age terminal strip at the lower po r tion of the Smar t Center . 2) Remo ve [...]

  • Page 19

    19 920-087-04 (3-05) The vent control lever is located behind the front c over on the lef t side of the unit. The unit is shipped in t he closed p osition with a lock ing screw in place. The screw must be removed to operate the lev er . When the lev er is back, ( OPEN), out side air is mixed with indoor ai r . When the le ver is for ward, (CLOSE D)[...]

  • Page 20

    20 920-087-04 (3-05) I. Star t-up Checklist  Inspect all components and accessories for damage before and after installation.  Check installation for compliance with all national and local codes and ordinances.  Read and follow all manufacturer's installation instructions.  Check that circuit breaker(s) and electrical wire sizes ar[...]

  • Page 21

    21 920-087-04 (3-05) Ap pe n d ix A: El ect ri c a l Wi r in g fo r 2 65 V o l t M o d e ls 1 . R emove the four control box retaining screws (A) and open the control bo x. 2. Pull the chassis p ower lead wires (B) (loc ated on the bot tom - right side of the c ontrol box ) through the plasti c bushing so they are located inside the c ontrol box. 3[...]

  • Page 22

    22 920-087-04 (3-05) J. Ro ut ine Main te nanc e 1 . Clean the unit air intake fi lter at least e ver y 3 0 0 to 35 0 hours of operation. Clean the fi lters wit h a mild detergent in warm water and allow to dr y thoroughly before reinstalling. 2. The indoor c oil (e vaporator coil), the outdo or coil (c ondenser coil) and base pan should be inspe[...]

  • Page 23

    23 920-087-04 (3-05) K . Basic T r ouble shoot ing T echniques Being familiar with the sequenc e of operation on Standard C ontro lled Operating Unit s or the operation of the Remote Thermostat Controlled Unit s is impor t ant. The following questi ons and answers may help to identif y per for mance problems. Mainten ance and Inspection T roublesho[...]

  • Page 24

    24 920-087-04 (3-05) Dia gnost ics The Friedrich Smar t Center continuously monitors t he PT AC unit operation and will store ser vic e co des if cer tain c onditions are witnesse d. In some cases the unit may take action and shut the unit of f until c onditions are c orrec ted. T o acc ess the er ror c ode menu press the ‘Heat ’ and ‘High F [...]

  • Page 25

    25 920-087-04 (3-05) Friedr ich P TAC Ac ce ss or ies NEW CON STRUCTION AC CES SO RIES MODEL NUMBER DESC RIPTI ON PHO TO PDX WS WA LL S L E E V E zinc coate d steel is prepared in an eleven-step process, t hen powder coate d with a po lyester fi nish and cured in an oven for e x c eptional durabilit y . T he wall sleeve is insulated for sound abso[...]

  • Page 26

    26 920-087-04 (3-05) ADDITIONAL A CCE SSORIE S MODEL NUMB ER DESC RIPTION PHO TO PXSE SLEEVE EX TENSION RETROFIT KIT G - 9 0 zinc c oated s t e e l , 2 . 4 " s l e e v e e x t e n s i o n a t t a c h e d t o t h e r o o m s i d e o f t h e sleev e to allow for the inst allation of a P- Ser ies F rie drich PT AC in a T -Ser ies sleeve . PDXDA L[...]

  • Page 27

    27 920-087-04 (3-05) Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedr ich.com PD-SERIES PACKAGED TERMINAL AIR CONDITIONERS LIMITED WARRANTY SAVE THIS CERTIFICA TE. It gives you specif ic rights, you may also have other rights which may vary from state to sta te and province to province. In the event tha[...]

  • Page 28

    F riedrich Ai r Conditi oning Co. Post Of f ice Box 15 4 0 • San A ntonio, T exa s 782 95 - 1 5 4 0 420 0 N. Pan A m Expre s s way • San Ant onio , T exas 7821 8 -521 2 (210 ) 357 - 4 4 0 0 • F A X (210 ) 357 - 4 4 8 0 www . fr i ed r i c h . co m Print e d in t he U.S.A . 920-087-04 (3-05)[...]