A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of FMI (V)B42, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FMI (V)B42 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FMI (V)B42. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FMI (V)B42 should contain:
- informations concerning technical data of FMI (V)B42
- name of the manufacturer and a year of construction of the FMI (V)B42 item
- rules of operation, control and maintenance of the FMI (V)B42 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FMI (V)B42 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FMI (V)B42, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FMI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FMI (V)B42.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FMI (V)B42 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. This replace is approved fo[...]

  • Page 2

    www .fmiproducts.com 109036-01M 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert. FOR YOUR SAFETY • Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of this[...]

  • Page 3

    www .fmiproducts.com 109036-01M 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUT[...]

  • Page 4

    www .fmiproducts.com 109036-01M 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o determine safest and most efcient location for replace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where replace will not be affected by drafts, air co[...]

  • Page 5

    www .fmiproducts.com 109036-01M 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a [...]

  • Page 6

    www .fmiproducts.com 109036-01M 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace [...]

  • Page 7

    www .fmiproducts.com 109036-01M 7 Figure 8 - Lineal Gain Hemmed End 8" Stainless Inner Pipe 12 3 / 8 " Galvanized Outer Pipe Figure 7 - Outside Air Kit Secure to Collars with Metal T ape, Screws or Straps (Min. of 1/4" x 20" in size) Air Inlet Location Must Allow For Bushes or Snow V ent Hood Required for W all Installation Air [...]

  • Page 8

    www .fmiproducts.com 109036-01M 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow [...]

  • Page 9

    www .fmiproducts.com 109036-01M 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 15" 34 3 / 4 " 1 18" 40" 1 1[...]

  • Page 10

    www .fmiproducts.com 109036-01M 10 VENTING INST ALLA TION Continued Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut out this section. 5 . Add next sections of pipe until end pe[...]

  • Page 11

    www .fmiproducts.com 109036-01M 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1) Place storm collar over pipe and slide down until it is[...]

  • Page 12

    www .fmiproducts.com 109036-01M 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule 10 FOOT RULE All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through roof and must be at least 2 feet above highest point o[...]

  • Page 13

    www .fmiproducts.com 109036-01M 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sur[...]

  • Page 14

    www .fmiproducts.com 109036-01M 14 OPTIONAL GAS LINE INST ALLA TION Continued W ARNING: If the replace has been used for wood burn- ing, rebox and chimney must be cleaned of soot, creosote and ashes be a qualied chimney cleaner . Creosote will ignite if heavily heated. OPERA TION AND MAINTENANCE Figure 23 - Glass Doors Cleaning Glass Clean[...]

  • Page 15

    www .fmiproducts.com 109036-01M 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued DAMPER HANDLE OPERA TION Damper handle, which opens and closes damper blade, is located inside rebox at center towards back w all (see Figure 24). Pushing handle back into keyway slot will free damper blade to automatically open. T o close,[...]

  • Page 16

    www .fmiproducts.com 109036-01M 16 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21[...]

  • Page 17

    www .fmiproducts.com 109036-01M 17 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 15 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 ** Insulation Pan • • 1 2 ** Air Separator • • 1 3 ** Firebox T[...]

  • Page 18

    www .fmiproducts.com 109036-01M 18 ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ANTI-DRAFT SHIELD (Round T op T ermination Only) ADS-8DM 30° OFFSET AND RETURN 30E-8DM ADJUST ABLE HOOD Antique Brass Finish - GA6053 Black Pai[...]

  • Page 19

    www .fmiproducts.com 109036-01M 19 F AN KIT - BK3 BLOWER KIT - BK OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION AK4F ACCESSORIES Continued SQUARE TOP TERMINA TION WITH LOUVERS ET -8DM, ET -8HT SQUARE TOP TERMINA TION WITH LOUVERS AND SLIP SECTION ETL-8DM, ETL-8HT MESH SQUARE TOP TERMINA TION ETO-8DM ME[...]

  • Page 20

    109036-01 Rev . M 03/1 1 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com[...]