FMI FGPN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of FMI FGPN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FMI FGPN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FMI FGPN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FMI FGPN should contain:
- informations concerning technical data of FMI FGPN
- name of the manufacturer and a year of construction of the FMI FGPN item
- rules of operation, control and maintenance of the FMI FGPN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FMI FGPN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FMI FGPN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FMI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FMI FGPN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FMI FGPN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For more information, visit www .fmiproducts.com UNVENTED (VENT -FREE) FIREB OX OWNER’S OPERA TION AND INST ALLA TION MANU AL MODEL FBPS, FGPN AND FGPN-LS 36" Peninsula Heat-Circulating Firebox W ARNING: If the information in these instructions is not followed exactly , a re or explosion may result causing property damage, personal injury[...]

  • Page 2

    www .fmiproducts.com 105163-01E 2 SAFETY W ARNING: Improper installation, adjustment, al - teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in - stallation and operational procedures. For assistance or additional information consult a qualied installer , service agency or the gas supplier . W[...]

  • Page 3

    www .fmiproducts.com 105163-01E 3 W ARNING: Do not use a blow - er insert, heat exchanger insert or o ther acce ssor y no t app rove d for use with this rebox. Do not al low fans t o bl ow d ire ctly into the rebo x. Av oid any drafts that alter burner ame patterns. Ceiling fans can create drafts that alter burner ame patterns. Altered [...]

  • Page 4

    www .fmiproducts.com 105163-01E 4 LOCAL CODES Install and use rebox with care. Follow all local codes. In the absence of local codes, use the latest edition of The Natio nal Fuel Gas Code ANS Z223.1 / NFP A 54 *. Firebox must be electrically grounded in accordance with the National Electrical Code, ANS/NFP A70 (latest edition). *Available from: [...]

  • Page 5

    www .fmiproducts.com 105163-01E 5 Figure 1 - Peninsula (Three-Sided) Firebox 4 1 / 2 " 4 3 / 4 " 33 3 / 4 " 3 5 / 8 " 4" 4" 1 1 / 4 " 1/2" 5/8" 19 1 / 2 " 40" 18 1 / 2 " 9 1 / 8 " 36 1 / 4 " 1 3 / 4 " 4" 1 1 / 2 " 24" 36 1 / 2 " 3" TYP . 42 1 / 2 &qu[...]

  • Page 6

    www .fmiproducts.com 105163-01E 6 AIR FOR COMB USTION AND VENTILA TION W ARNING: This heater shall not be installed in a room or space unless the required vol - ume of indoor combustion air is provided by the method de - scribed in the National Fuel Gas Code, ANSI Z223.1/NFP A 54, the International Fuel Gas Code, or applicable loca l codes. Read th[...]

  • Page 7

    www .fmiproducts.com 105163-01E 7 DETERMINING FRESH-AIR FLOW FOR FIREBOX LOCA TION Determining if Y ou Have a Conned or Unconned Space Use this work sheet to determine if you have a conned or unconned space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills[...]

  • Page 8

    www .fmiproducts.com 105163-01E 8 AIR FOR COMB USTION AND VENTILA TION Continued Figure 3 - V entilation Air from Inside Building Or Remove Door into Adjoining Room, Option 2 V e ntilation Grills Into Adjoining Room, Option 1 4" Figure 4 - V entilation Air from Outdoors Outlet Air V e ntilated Attic Outlet Air Inlet Air Inlet Air V e ntilated [...]

  • Page 9

    www .fmiproducts.com 105163-01E 9 CAUTION: Log heaters in - st all ed in t hi s  re box cr eat e w ar m air currents. These currents move heat to wall surfaces next to re - b ox . In st al li ng  re bo x ne xt t o vi ny l or cloth wall coverings or operat - ing rebox where impurities (such as , b ut no t li mi ted to , tob acc o smoke, [...]

  • Page 10

    www .fmiproducts.com 105163-01E 10 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placing custom mantel above built-in re - box, you must meet the minimum allowable clearance between mantel shelf and top of rebox opening shown in Figure 7. These are the minimum allowable mantel clearances for a safe installation. Use [...]

  • Page 11

    www .fmiproducts.com 105163-01E 11 INST ALLA TION Continued 1 1 / 2 " Max. 3/8" Max. 4" 8" Min. from adjacent wall to fireplace opening SAFE ZONE Combustible material must not overlap more than 3/8" onto black metal front face. Nailing Flange Drywall Figure 9 - Framing for Built-In Firebox Installation, T op V iew Min. from[...]

  • Page 12

    www .fmiproducts.com 105163-01E 12 INST ALLA TION Continued CAUTION: Do not use exces- sive force to remove the knock - ou t. T oo much f orc e ma y dama ge the rebrick concrete insert. A manual shutoff valve, CSA certied and complying with the National Fuel Gas code, ANS Z223.1/NFP A 54 , must be included within 6' of the vent-free r[...]

  • Page 13

    www .fmiproducts.com 105163-01E 13 Prepare incoming black iron gas line with T eon tape or pipe joint com poun d (chec k with local codes as to the use of T eon tape). Com - pounds used on threaded joints of gas piping shall be resistant to the action of propane/LP and shoul d be appl ied light ly to ensu re excess sealant does not enter the [...]

  • Page 14

    www .fmiproducts.com 105163-01E 14 INST ALLA TION Continued Note: A 120V supply connection to the leads to the receptacle must be provided for use with the optional blower kit whether installed during or after initial rebox installation. Y ou may not be able to install a supply connection after the nal installation is completed. HEA T DEFLECT[...]

  • Page 15

    www .fmiproducts.com 105163-01E 15 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537. When calling, have ready: • your na[...]

  • Page 16

    www .fmiproducts.com 105163-01E 16 P ARTS MODELS FBPS, FGPN AND FGPN-LS **These items are used on both sides of fireplace. 8** 15 17** 17** 17** 7-1 7-2 7-3 2 17** 1 1 ** 17** 17 12 6 16 13 10** 5** 17 17 15 16 4 16 16 6 16 15 17** 17** 18 Ty p. Ty p. Ty p. 8** 17** 17** 9** 14 16 1 3[...]

  • Page 17

    www .fmiproducts.com 105163-01E 17 P ARTS MODELS FBPS, FGPN AND FGPN-LS This list contains replaceable parts used in your rebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 *** Firebox Assembly 1 2 *** Firebox Bottom 1 3 *** Firebox T op 1 4 23982 T [...]

  • Page 18

    www .fmiproducts.com 105163-01E 18 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________[...]

  • Page 19

    www .fmiproducts.com 105163-01E 19 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________[...]

  • Page 20

    105163-01 Rev . E 01/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES New Products Standard Warranty: FM I PR O DU CT S, LL C wa rr an ts th is ne w p ro du ct an d an y pa rt s th er eo f t o be fr ee fr om de fe c ts i n ma te r ia l a n d wo r k ma ns hi p f or a p er io d o f t wo ( 2 ) y ea r s fr om t he da te o f  rs t[...]