A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Fluke PN 3612805, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fluke PN 3612805 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Fluke PN 3612805. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Fluke PN 3612805 should contain:
- informations concerning technical data of Fluke PN 3612805
- name of the manufacturer and a year of construction of the Fluke PN 3612805 item
- rules of operation, control and maintenance of the Fluke PN 3612805 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fluke PN 3612805 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fluke PN 3612805, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fluke service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fluke PN 3612805.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Fluke PN 3612805 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PN 3612805 July 2010 © 2010 Fluke Corp oration. All ri ghts reserved. Pr inted in Taiwan. S pecifications are subject to chang e without no tice. All product nam es are trademarks o f their respecti ve companies. 373 Clamp Meter Users Manual[...]

  • Page 2

    LIMITED WARRANTY A ND LIMITATION OF LIA BILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchas e. This warrant y does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alter ation, contamination, or abnormal conditions of operation or ha ndlin g. Resell[...]

  • Page 3

    i Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information ..................................................[...]

  • Page 4

    373 Users Manual ii[...]

  • Page 5

    1 Introduction XW Warning Read "Safety Information" before you use the Meter. The Fluke 373 Clamp Meter (the Meter) measures true-rms ac and dc voltage, ac current, resistance, and capacitance. How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-4 43-5853) ?[...]

  • Page 6

    373 Users Manual 2 Or, visit Fluke's website at www.fluke.com . To register your product, visit http://register.fluke.com . To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals . Safety Information A Warning identifies conditions and actions t hat pose hazard(s) to the user; A Caution identifi[...]

  • Page 7

    Clamp Meter Safety Information 3 • Remove the test leads from the Meter before th e battery door is opened. • Examine the test leads for damaged insulation o r exposed metal. Check test lead continuity. Repl ace damaged test leads be fore using the Meter. • Do not use the Meter if it o perates incorrectly. Protecti on can be compr omised. Whe[...]

  • Page 8

    373 Users Manual 4 • Connect the common t est lead before co nnecting the li ve test lead. When disconnecting test lea ds, disconnect the li ve test lead first. • Do not work alone so assista nce can be rendered in a n emergency. • Use extreme caution w hen working aroun d bare conductors or bus bars. Contact with the conduc tor could result [...]

  • Page 9

    Clamp Meter Safety Information 5 Table 1. Symbols Symbol Meaning S ymbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. X Hazardous voltage P Conforms to European Union directives. W Risk of Danger. Important inf[...]

  • Page 10

    373 Users Manual 6 Symbol Meaning S ymbol Meaning CAT III IEC Measurement Category III CAT III equipment has protection against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. CAT IV IEC Measurement Category IV CAT IV equipment has pro[...]

  • Page 11

    Clamp Meter The Meter 7 The Meter 1 ghl008.eps[...]

  • Page 12

    373 Users Manual 8 Auto Off 20 ghl001.eps[...]

  • Page 13

    Clamp Meter The Meter 9 Backlight ghl002.eps[...]

  • Page 14

    373 Users Manual 10 A ghl003.eps[...]

  • Page 15

    Clamp Meter The Meter 11 V V V V or > 30 V ghl004.eps[...]

  • Page 16

    373 Users Manual 12 < 30 ghl005.eps[...]

  • Page 17

    Clamp Meter The Meter 13 CAT III 600 V CAT I V 300 V 1 3 2 HOLD HOLD ghl006.eps[...]

  • Page 18

    373 Users Manual 14 1 2 3 ghl007.eps[...]

  • Page 19

    Clamp Meter The Meter 15 Electrical Specifications AC Current Range ..................................................... 600.0 A Resolution ............................................... 0.1 A Accuracy ................................................. 2 % ± 5 digits (48 – 62 Hz) Crest Factor (50/60 Hz) .......................... 2.5 @ 600 A AC[...]

  • Page 20

    373 Users Manual 16 Accuracy ................................................. 1 % ± 5 digits Continuity Beeper ................................... ≤ 30 Ω Capacitance Range ..................................................... 10.0 – 100.0 μ F / 1000 μ F Resolution ............................................... 0.1 μ F/1 μ F Accuracy ...[...]

  • Page 21

    Clamp Meter The Meter 17 Operating Altitude ................................... 3000 meters Storage Altitude ...................................... 12,000 meters EMI, EMC ................................................ Meets all applicable requirements in EN61326-1:2 006 Temperature Coefficients ........................ Add 0.1 x spec ified accura[...]

  • Page 22

    373 Users Manual 18[...]