A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of FireplaceXtrordinair 36CF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FireplaceXtrordinair 36CF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FireplaceXtrordinair 36CF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FireplaceXtrordinair 36CF should contain:
- informations concerning technical data of FireplaceXtrordinair 36CF
- name of the manufacturer and a year of construction of the FireplaceXtrordinair 36CF item
- rules of operation, control and maintenance of the FireplaceXtrordinair 36CF item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FireplaceXtrordinair 36CF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FireplaceXtrordinair 36CF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FireplaceXtrordinair service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FireplaceXtrordinair 36CF.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FireplaceXtrordinair 36CF item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    36 C F S T /Pier Gas F ir ep lace Tested and Listed by OMNI-Test Laboratories, Inc. Portland, Oregon Report # 028-F-87-5 ANSI Z21.88a-2007 • Built-In Direct Vent Fireplace • Natural Gas or Propane • Residential or Mobile Home • Bedroom Approved WARNING: If the information in these instructions is not followed exactly, a fire or explosion ma[...]

  • Page 2

    2 Introduction © Travis Industries 4090102 100-01212_000 Overview This manual details the installation requirements for the 36 CF ST and Pier fireplace. For operating and maintenance instructions, refer to the 36 CF ST/Pier Owner's Manual (part # 100-01213). Listing Details This appliance was listed by OMNI Test Labs to ANSI Z21.88 - report #[...]

  • Page 3

    Table of Contents 3 © Travis Industries 4090102 100-01212_000 Introduction Overview ................................................................. 2 Listing Details .......................................................... 2 Safety Precautions Safety Precautions ................................................... 4 Features and Specifications [...]

  • Page 4

    4 Safety Precautions © Travis Industries 4090102 100-01212_000 Safety Warnings: • Failure to follow all of the requirements may result in property damage, bodily injury, or even death. • This unit must be installed by a qualified installer to prevent the possibility of an explosion. • This appliance must be installed in accordance with all l[...]

  • Page 5

    Safety Precautions 5 © Travis Industries 4090102 100-01212_000 Safety Warnings (continued): • Allow the heater to cool before carrying out any maintenance or cleaning. • Operate the heater according to the instructions included in this manual. • If the main burners do not start correctly turn the gas off at the gas control valve and call you[...]

  • Page 6

    6 Features and Specifications © Travis Industries 4090102 100-01212_000 Installation Options • Residential or Mobile Home • Flush or Recessed Face • Raised or Floor Placement • Horizontal or Vertical Vent • Bedroom Approved Specifications Natural Gas Propane Maximum BTU Input Per Hour 58,000 58,000 Minimum BTU Input on Low 27,000 27,000 [...]

  • Page 7

    Installation (for qualified installers only) 7 © Travis Industries 4090102 100-01212_000 Packing List • Glass LatchTool • Log Set with Embers and Rock Wool • Remote Control with Wall Mount • LP Conversion Kit (2 orifices and 1 rate screw) • Battery Box • Learn Switch with 12’ Battery Box Wire • Andiron Brackets (4) • Fiber Board [...]

  • Page 8

    8 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Massachusetts Requirements NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment install[...]

  • Page 9

    Installation (for qualified installers only) 9 © Travis Industries 4090102 100-01212_000 Preparing the Fireplace Stand-offs This appliance is shipped with the header and side stand-offs in the retracted position. These stand- offs must be placed in their upright position prior to installing the fireplace. Secure the stand-offs to the framing with [...]

  • Page 10

    10 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Fireplace Placement Requirements • Fireplace must be placed in a room with a minimum 96” ceiling. • Fireplace must be placed directly on the sub-floor or wood platform (not on linoleum or carpet). • Fireplace must be installed on a level surface capab[...]

  • Page 11

    Installation (for qualified installers only) 11 © Travis Industries 4090102 100-01212_000 Minimum Framing 36 CF ST (See Through) 62-1/2" Minimum 78” Fireplace Enclosure Height NOTE: W e recommend you install the framing after placing the fireplace in position. As an alternative, you may omit the framing above one side and back of the firepl[...]

  • Page 12

    12 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Framing Dimensions – 36 CF Pier 18-1/4" 22-1/2 ” NOTE : Do not build into this area - it must be left clear to provide adequate clearance for the vent. 49-3/8 ” 56-1/2 ” Minimum 78 ” Fireplace Enclosure Height Right Left Front Back Vent Clearan[...]

  • Page 13

    Installation (for qualified installers only) 13 © Travis Industries 4090102 100-01212_000 Attaching Stand-Offs to Framing a b c d e Figure 7[...]

  • Page 14

    14 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Required Electrical Connection Make sure power to the heater has been turned off prior to installation (disable the breaker). Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace. This fireplace utilizes 110 VAC to power[...]

  • Page 15

    Installation (for qualified installers only) 15 © Travis Industries 4090102 100-01212_000 Battery Pack / Learn Switch Installation • The battery pack and learn switch must be mounted inside a junction box in a location that may be reached by the 12’ long battery box wires (see Figure 8 ). Staple the two wires near the junction box. This preven[...]

  • Page 16

    16 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Steps for Installing the Battery Box and Learn Switch 1. Remove the control cover and attach the 12’ long battery box wire to the quick connects on the receiver module (see Figure 9 below). Route the battery box wire through the opening below the cover. A t[...]

  • Page 17

    Installation (for qualified installers only) 17 © Travis Industries 4090102 100-01212_000 Remote Synchronization The fireplace is shipped with the remote and fireplace pre-synchronized . Do not synchronize the remote unless you are 100% sure it does not work correctly. Synchronizing the Remote NOTE : The fireplace must have power and the transmitt[...]

  • Page 18

    18 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: • Flexible connector must not be [...]

  • Page 19

    Installation (for qualified installers only) 19 © Travis Industries 4090102 100-01212_000 Vent Requirements • The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own se[...]

  • Page 20

    20 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Vent Clearances IN THE ENCLOSURE (under 78") Vertical or Horizontal Sections: 6" Clearance Above 3-1/2" Clearance To The Side 2" Clearance Below Horizontal Penetrations (through walls, etc.) (thimble is required - sku 98900030) 4" Cle[...]

  • Page 21

    Installation (for qualified installers only) 21 © Travis Industries 4090102 100-01212_000 Approved Vent Configurations Exhaust Restrictor Adjustment An exhaust restrictor is built into exhaust vent at the rear of the fireplace. It is used to adjust the flow rate of exhaust gases. Depending upon vent configuration, you may be required to adjust the[...]

  • Page 22

    22 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Rear Vent, Horz. Term. (1 45 ° Elbow) • The vent must not exceed 5 feet (see chart below). • Use Exhaust Restrictor Position # 1. • Horizontal sections require a 1/4" rise every 12" of travel 0 feet 5 feet (max[...]

  • Page 23

    Installation (for qualified installers only) 23 © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Rear Vent, Horz. Term. (1 45 ° , 2 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 fee[...]

  • Page 24

    24 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Rear Vent, Horz. Term. (1 45 ° , 4 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 fee[...]

  • Page 25

    Installation (for qualified installers only) 25 © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Rear Vent, Vert. Term. (1 45 ° , 3 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 fee[...]

  • Page 26

    26 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Top Vent, Horz. Term. (1 45 ° ,1 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 feet [...]

  • Page 27

    Installation (for qualified installers only) 27 © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Top Vent, Horz. Term. (1 45 ° , 3 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 feet[...]

  • Page 28

    28 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Top Vent, Vert. Term. (1, 3, or 5 45 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 feet [...]

  • Page 29

    Installation (for qualified installers only) 29 © Travis Industries 4090102 100-01212_000 Approved Vent Configuration – Top Vent, Vert. Term. (1 45 ° ,2 90 ° Elbows) • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. 5 feet 0 feet 0 feet 5 feet 0 feet 20 feet 20 feet 5 feet 10 feet [...]

  • Page 30

    30 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Termination Requirements ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" clearance from any door or window B Minimum 12" above any grade, veranda, porch, deck or balcony C Minimum 3-3/8" from outside corner walls N[...]

  • Page 31

    Installation (for qualified installers only) 31 © Travis Industries 4090102 100-01212_000 Hearth Requirements NOTE : Whenever using a hearth over 1” thick, the fireplace will need to be rai sed. Flush Hearth Side View Min.10” Min. 64” (on ST, Pier will vary) Min. 3/4” Max 1” Non-Combustible Hearth Fireplace 1 ” Plywood (OSB, etc.) Fram[...]

  • Page 32

    32 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Hearth Requirements – Recessed Hearth A hearth is not required if the fireplace is raised 6 ” above the flooring surface. NOTE: Make sure to accommodate the flooring surface - this distance must be measured from the top of carpeting or other flooring mate[...]

  • Page 33

    Installation (for qualified installers only) 33 © Travis Industries 4090102 100-01212_000 Facing Requirements • Attach the included fiber board (or other non-combustible) to the fireplace and framing (see Figure 22 below). This non-combustible facing must extend from the base of the fireplace to the header and to the framing members on both side[...]

  • Page 34

    34 Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Non-Combustible Facing • Non-combustible facing on the front of the fireplace must extend a minimum 16-1/2” from the top of the glass frame (49-1/2” from the base of the fireplace). Above 16-1/2” combustible facing may be used (see “Mantel Requireme[...]

  • Page 35

    Installation (for qualified installers only) 35 © Travis Industries 4090102 100-01212_000 Mantel Requirements • The mantel (combustible or non-combustible) must be a minimum 49-1/2” above the base of the fireplace (see Figure 2 4) . • The maximum mantel depth is 12” (measured from the face). Max. 12 ” Base of the Fireplace Min. 49-1/2 ?[...]

  • Page 36

    36 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Steps for Finalizing the Installation WARNING: Prior to removing the glass, shut off gas to the appliance (or remove the batteries from the battery box and shut off electricity to the fireplace). This prevents any chance of accidental burner ig[...]

  • Page 37

    Finalizing the Installation (for qualified installers only) 37 © Travis Industries 4090102 100-01212_000 7. Check the air shutter following the directions below. Air Shutter Adjustment Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessa[...]

  • Page 38

    38 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Glass Frame Removal and Installation WARNING: Prior to removing the glass, shut off gas to the appliance (or remove the batteries from the battery box and shut off electricity to the fireplace). This prevents any chance of accidental burner ign[...]

  • Page 39

    Finalizing the Installation (for qualified installers only) 39 © Travis Industries 4090102 100-01212_000 Log Set Installation Ember Placement Place the embers along the firebox floor and burner to help conceal the burner . Make sure none of the embers are directly over the burner holes. See the photo below. Rock Wool Placement The rock wool must b[...]

  • Page 40

    40 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Log Installation NOTE : The logs are a mirror-image (same logs fit on left and right side). Both the 36 CF See Through (ST) and Pier use the same log set. See the pictures below for log placement Bottom 3 logs. Middle 2 logs.[...]

  • Page 41

    Finalizing the Installation (for qualified installers only) 41 © Travis Industries 4090102 100-01212_000 Top 2 logs (last 2 logs) Picture from opposite side[...]

  • Page 42

    42 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 Picture from end (Pier only)[...]

  • Page 43

    Finalizing the Installation (for qualified installers only) 43 © Travis Industries 4090102 100-01212_000 LP Conversion Instructions Install the conversion kit prior to installing the fireplace to ensure proper gas use. 1 Remove the glass (see page 3 6). Remove the logs and coals (if installed - page 3 9) 2 Remove the grate (4 screws hold it in pla[...]

  • Page 44

    44 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 5 Remove both side burners (4 screws hold each one in place). 6 Remove the center burner (2 screws hold it in place).[...]

  • Page 45

    Finalizing the Installation (for qualified installers only) 45 © Travis Industries 4090102 100-01212_000 7 The manifolds that secure the three orifices are visible at this point. Detach the air shutter stopper on the mixing tube brackets to gain full access to the orifices (2 screws hold them in place). 8 Remove the NG orifices and replace with th[...]

  • Page 46

    46 Finalizing the Installation (for qualified installers only) © Travis Industries 4090102 100-01212_000 1 1 The gas control valve has a propane conversion shaft that alters the outlet pressure. Remove the rubber cap over the propane conversion shaft and twist the small knob so the line points to “LP” (see Figure 27 ). Pilot Adj. Inlet Outlet [...]

  • Page 47

    Finalizing the Installation (for qualified installers only) 47 © Travis Industries 4090102 100-01212_000 Power Heat Duct Installation The optional power heat duct ma y b e used with this fireplace. Refer to the part numbers below if y ou wish to inst a this accessor y . Instructions are includ with the power heat duct. • Power Heat Duct ( 985007[...]

  • Page 48

    48 Index © Travis Industries 4090102 100-01212_000 Index Andiron Installation .............................................4 7 Additional Items Required ....................................7 Air Shutter Adjustment ........................................3 7 Altitude Considerations ........................................1 9 Approved Vent .........[...]