The rules should oblige the seller to give the purchaser an operating instrucion of FieldServer FS-8700-59, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FieldServer FS-8700-59 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FieldServer FS-8700-59. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FieldServer FS-8700-59 should contain:
- informations concerning technical data of FieldServer FS-8700-59
- name of the manufacturer and a year of construction of the FieldServer FS-8700-59 item
- rules of operation, control and maintenance of the FieldServer FS-8700-59 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FieldServer FS-8700-59 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FieldServer FS-8700-59, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FieldServer service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FieldServer FS-8700-59.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FieldServer FS-8700-59 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    a Sierra Monitor Company APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after May 1, 2001 Instruction Manual Part Number FS - 8700 - 59 3/13/03 Driver Manual (Supplement to the FieldServer Instruction Manual) FS - 8700 - 59 Canatal Satchnet Driver[...]

  • Page 2

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www .fieldserver.com E - mail: support @fieldserver.com Table of Contents TABLE OF CONTENTS 1. Canatal Satchnet Protocol Driver Description ......................................[...]

  • Page 3

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 1 1. Canatal Satchnet Protocol Driver Description The Canatal Satchnet Protocol Driver allows the FieldServer to tran[...]

  • Page 4

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 2 3. Hardware Connections The FieldServer is connected to the as shown below. Configure the Canatal Driver according [...]

  • Page 5

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 3 4. Configuring the FieldServer as a Canatal Satchnet Protocol Driver Client For a detailed discussion on FieldServe[...]

  • Page 6

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 4 4.2 Client Side Connections Section Title Connections Column Title Function Legal Values Port Specify which port th[...]

  • Page 7

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 5 4.4 Client Side Map Descriptors 4.4.1 FieldServer Specific Map Descriptor Parameters Column Title Function Legal Va[...]

  • Page 8

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 6 4.4.4 Map Descriptor Example In this ex ample two map descriptors are provided. The first reads Device 11 ( a Serie[...]

  • Page 9

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldser ver.com Page 7 4.4.5 Map Descriptor Example 2 In this example two map descriptors are provided. They both read table 16 of a serie[...]

  • Page 10

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 8 5. Configuring the FieldServer as a Canatal Satchnet Protocol Driver Server For a detailed discussion on FieldServer[...]

  • Page 11

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 9 5.2 Server Side Connections Section Title Connections Column Title Function Legal Values Port Specify which port the[...]

  • Page 12

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 10 5.4 Server Side Map Descriptors 5.4.1 FieldServer Specific Map Descriptor Parameters Column Title Function Legal Va[...]

  • Page 13

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 19 91 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 11 5.4.4 Map Descriptor Example In this example the F ieldServer answers queries from a Canatal Satchnet master devic[...]

  • Page 14

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 19 91 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 12 6. Driver Notes 6.1 Canatal Device Data Tables Canatal Devices's have their data organized into data tables. [...]

  • Page 15

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 19 91 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 13 Series Table Data Format Max Read Description Notes 5 10 CANA_PERCENT 4 R Analog Outputs 5 11 CANA_BYTE 48 RW Alar[...]

  • Page 16

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 19 91 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 14 The Data formats are used internally in the driver but they do indicate to the user the type of data array that sh[...]

  • Page 17

    FS - 8700 - 59 Canatal Sachnet Driver Manual FieldServer Technologies 19 91 Tarob Court Milpitas, California 95035 (408) 262 - 2299 fax: (408) 262 - 9042 Visit our website: www.fieldserver.com E - mail: support @fieldserver.com Page 15 Errors 8 - 12 are produced when parsing a response from a Canatal device. They may result from a corrupted message[...]