Exergen 2000C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Exergen 2000C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Exergen 2000C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Exergen 2000C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Exergen 2000C should contain:
- informations concerning technical data of Exergen 2000C
- name of the manufacturer and a year of construction of the Exergen 2000C item
- rules of operation, control and maintenance of the Exergen 2000C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Exergen 2000C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Exergen 2000C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Exergen service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Exergen 2000C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Exergen 2000C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T emporal Scanner TM 2000C EXE RGE N Quick Check-List: - Read instructions completely before using - See www .temporalscanner .com for Educational Video - Remove protective cap before using - Reads arterial temperature, which is a core temperature very close to rectal temperature (See pg. 9) - Sensor should be clean (See pg. 12) - If perspiration i[...]

  • Page 2

    READ ALL INSTRUCTIONS BEFORE USING When using the product, especially when children are present, basic safety precautions should always be followed, including the following: z This product is intended for household use only . For information on thermometers for professional use, please see www .exergen.com, or call 617-923-9900. z Use this product [...]

  • Page 3

    z If your thermometer will not be used regularly , remove the battery to prevent possible damage due to chemical leakage. If the battery leaks, remove carefully . Do not allow bare skin to touch leaking fluid. z Dispose of used batteries properly . Do not wrap them in metal or aluminum foil. Wrap them in newspaper before disposing of them. Do not b[...]

  • Page 4

    The T emporalScanner has patented software, providing arterial heat balance. This unique process determines temperature by accurately measuring the balance between the tissues warming from arterial blood and tissues cooling/ warming caused by heat loss/gain to the environment. Why take temperature measurements at the skin surface over the temporal [...]

  • Page 5

    5 Probe Cone Probe Sensor Lens Probe LCD Display Screen LED Indicator Light SCAN Button Automatic turn-off in 30 seconds LED Indicator Light Thumb-Push Ridges Battery Compartment 9-volt alkaline battery z T o Scan: Depress the button. The instrument will continually scan for the highest temperature (peak) as long as the button is depressed. z Beepi[...]

  • Page 6

    What you should know before using the T A T : z Measure only the side of the head exposed to the environment. Anything covering the area to be measured (hair , hat, wig, bandages) would insulate the area, resulting in falsely high readings. z Slide the thermometer straight across the forehead, not down the side of the face. Midline on the forehead,[...]

  • Page 7

    T o ensure that the reading always reflects the body temperature accurately , you need to take account of the following factors which may affect an accurate reading. Sweating: When a fever resolves, your body may bring its temperature down by sweating. The T emporalScanner detects this reduction in temperature immediately - long before a rectal the[...]

  • Page 8

    How to T ake a T emperature 1. Remove protective cap before use. Be sure lens is clean. If not, clean with cotton swab dipped in alcohol and let dry . Hold the ther- mometer as shown . 2. Gently position the probe flush (flat) on the center of the forehead, midway between the eyebrow and the hairline. Press and hold the SCAN button. 3. Lightly slid[...]

  • Page 9

    Normal Body T emperature (BT) Normal BT is not a single temperature, but a range of temperatures influ- enced by age, time of day , and measurement site. Y ou can establish your family’s normal ranges by taking a number of temperatures from each mem- ber during a day and keeping records of them. Many people may not have an elevated temperature ev[...]

  • Page 10

    On a stable resting individual, temporal artery temperature is about the same as a rectal temperature, and approximately 0.8°F (0.4°C) higher than an opti- mum oral temperature. However , during fever episodes, the difference can be much higher , mainly because of the much greater speed of the T A com- pared to ear , oral, or rectal sites in resp[...]

  • Page 11

    Rectal T emperature Artifacts: Rectal temperature should only be con- sidered as a good approximation of core temperature when the patient’s thermal balance is stable, 8 and may be misleading after antipyretics, physical exercise, or other intervention that may change temperature quickly . Axillary T emperature Artifacts: Based on strong evidence[...]

  • Page 12

    Cleaning the Instrument The T emporalScanner is an optical instrument. Like a camera or eye glasses, a dirty lens will distort the view . If the thermometer is unable to see the heat clearly , it will be unable to measure it accurately , resulting in low readings. z Probe lens and cone should be shiny clean, if not, wipe with a small cloth or swab [...]

  • Page 13

    Changing the Battery Blinking battery icon with temperature displayed: battery is low but will still operate correctly . Replace soon. Blinking battery icon with 2 dashes: not enough energy in the battery to measure correct temperature. Replace battery . Remove the battery compartment door by pushing down on the ridges with your thumb, and pushing [...]

  • Page 14

    Display Messages A flickering Scn on display is visible during measurement. At completion, releasing the button will display and lock temperature on the screen for 30 seconds. The target temperature measured is higher than 107.6°F (42°C). The target temperature measured is lower than 60°F (15.5°C). T emperature of the thermometer is higher than[...]

  • Page 15

    Clinical Accuracy Meets ASTM E1965-98 and EN60601-1 standards for electronic and radiation thermometers to the extent applicable to thermometers which measure the surface of the skin over the temporal artery . Regulatory Approvals CE Mark to -0197, TUV , Declaration of Conformity-ISO 9003/08.94, NIST certifiable traceable calibrations, UL listed. E[...]

  • Page 16

    One Y ear Warranty Exergen Corporation warrants each new Exergen T emporalScanner 2000C (except battery) against defects in materials or workmanship for a period of one year from the date of purchase, and agrees to repair or replace any defective product without charge. IMPORT ANT : This warranty does not cover damage resulting from accident, mis- [...]