Enviro 50-1574 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Enviro 50-1574, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enviro 50-1574 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Enviro 50-1574. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Enviro 50-1574 should contain:
- informations concerning technical data of Enviro 50-1574
- name of the manufacturer and a year of construction of the Enviro 50-1574 item
- rules of operation, control and maintenance of the Enviro 50-1574 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enviro 50-1574 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enviro 50-1574, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enviro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enviro 50-1574.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Enviro 50-1574 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PELLET ST OVE Ev olution PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area. SHERWOOD INDUSTRIE[...]

  • Page 2

    2 Safety Warnings & Recommendations..................................................................................... ..........3 Installation................................................................................................................................ .....6 Rating Label Location............................................[...]

  • Page 3

    3 Safety W arnings & R ecommend a tions * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modif[...]

  • Page 4

    4 Safety W arnings & R ecommend a tions CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will v ary due to the ash content of the f uel used and the oper ation of the stove. It is advisable to inspect and clean the exhaust vent semi- annually or every two tons of pellets. The appliance, flue ga[...]

  • Page 5

    5 Safety W arnings & R ecommend a tions FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “ Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly . NOTE: Extractor fans when operating in the [...]

  • Page 6

    Remove the two (2) wood screws (one on either side of the unit) to remove the unit from the pallet. Inst alla tion R ATING L ABEL L OCATION : The rating label is located on the inside of the ash pan co ver . D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, gara[...]

  • Page 7

    Inst alla tion D IMENSIONS : 7 IMPOR T ANT : When not installing the optional Hearth Pad on the unit, the minimum requirements for protection on combustibles floors are a width of 620mm (24”) & depth of 670mm (26”) under the unit. 22 1 / 4 " (565 mm) 33 1 / 16 " (840 mm) 21 1 / 4 " (539 mm) 5 13 / 16 " (147 mm) 26 [...]

  • Page 8

    Inst alla tion C LEARANCES TO C OMBUSTIBLES : This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability . A LCOVE C LEARANCES : This unit may be installed in an [...]

  • Page 9

    9 Inst alla tion H EARTH P AD P EDESTAL I NSTALLATION : This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional Hearth Pad is installed. If this unit is to be installed onto a carpeted surf ace, a solid pad must be used underneath the Optional Hearth P ad for stability . Carefully place the the pel let[...]

  • Page 10

    10 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elev ation. It is recommended that at least fiv e feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibi[...]

  • Page 11

    Inst alla tion O UTSIDE F RESH -A IR C ONNECTION : This Heater must have adequate air for proper combustion in the room that it is installed. Figure 7: Outside Air Connection. E XHAUST A ND F RESH A IR I NTAKE L OCATIONS : The Exhaust Starter Tube can be installed 2 ways: Angled towards the center - Use a T ee with vertical for a “centered” ver[...]

  • Page 12

    Figure 10: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION : 4" (10 cm) 4" (10 cm) Fresh Air Intake W all thimble manufactured by pellet vent manufacturer . ENVIRO EF5 1 / 4 ” Lag Bolts Securely Fastened Ground Wire Directly to Metal Chassis Optional Hearth Pad Flooring Steel Frame ● Secure the heater to the floor usin[...]

  • Page 13

    13                   Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the v[...]

  • Page 14

                            Inst alla tion T HROUGH W ALL W ITH V ERTICAL R ISE AND H ORIZONTAL T ERMINAT[...]

  • Page 15

    15 2 ft (61 cm) Rain Cap (ensure cap is at least 3ft (91cm) above the roof at the lowest point) Roof Flashing Roof Rafter Fire Stop with Support Collar Ceiling Joist V ertical V ent Pipe Clean Out T ee with Pipe Adapter EF 5 NOTE: All vent sections must maintain 3 inches (7.6 cm) clearances to combustibles. Inst alla tion I NSIDE V ERTICAL I NSTALL[...]

  • Page 16

    H EARTH M OUNT I NSTALLATION : EF 5 Existing Fireplace Clean Out T ee Fireplace Damper Location Rain Cap Seal Plate V ent Pipe (single wall stainless flex pipe or PL vent) Existing Masonary Flue Flexible V ent Connector (Use this 5 ft section of pipe to vent past fireplace damper or smoke shelf) Inst alla tion Rain cap Flashing 24" (61 cm) 4&q[...]

  • Page 17

    17 Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : The Evolution can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remov e the left hand cabinet side by removing the two (2) screws down the front. Loosen the three screw[...]

  • Page 18

    Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable EF 5 90° Elbow 45°Elbow with Rodent screen or stainless steel termination hood 2ft Riser Pipe Adaptor Exterior Blower and Housing W all Strap T o supply power to the exhaust Install an amour coated electrical cable fr om[...]

  • Page 19

    19 EF5 Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall instal lations. Ensure that vent pipe is properly secured to [...]

  • Page 20

    Inst alla tion T HERMOSTAT I NSTALLATION : 1. Install the wall thermostat (12 or 24 V olt rated) in a location that is not to close too the unit but will effectively heat the desir ed area. 2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat. O PTIONAL S LIDER /D AMPER I NSTALLATION : If the unit has been p[...]

  • Page 21

    21 Inst alla tion S LIDER /D AMPER S ET -U P : This is used to regulate the airflow through the pellet stove. The slider damper should be set by a trained technician using magnehelic. The slider damper is located behind the left side panel. T o open the left side panel, undo the one screw located in the upper front corner of the cabinet side betwee[...]

  • Page 22

    T roubleshooting DO NOT: ● Service the stove with wet hands. The sto ve is an electrical appliance, which ma y pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication. WHAT TO DO IF: 1. The sto[...]

  • Page 23

    23 T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly , the unit may require cleaning or a new sensor . Contact your local dealer for service. ü [...]

  • Page 24

    T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verify that the blower turns on; if , not contact your local dealer for service. 8. Ignitor- the pellets will not light. ü Everything else in the stov e operate[...]

  • Page 25

    25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Exterior Exhaus[...]

  • Page 26

    P ar ts List Reference # Description Part # 1 120°F (49°C) Ceramic F an T emperatur e Sensor EC-001 Window Channel T ape - 1.8m (72”) EC-058 2 Auger Motor - 220V EF-001-220V Combustion Blower Mounting Gasket EF-011 Combustion Blower Housing Gasket (Circular) EF-012 3 High Limit T emp Sensor 200°F (93°C) Manual R eset EF-016 4 V acuum Switch -[...]

  • Page 27

    27 P ar ts List Reference # Description Part # Door Gasket - 7ft (213 m) 50-088 23 T op Louver Set - Nickel 50-097 24 Ash Shelf Louver 50-162 Slider Damper Rod & Knob 50-293 T op Glass Retainer 50-294 Control P anel T ouch Latch 50-323 Circuit Board Wire Harness 50-332 Hopper Guard 50-333 25 Convection Blower - 220V 50-513 26 Convection Blower [...]

  • Page 28

    P ar ts Diagr am - Components          EVOLUTION - Components May 2007       28[...]

  • Page 29

    29 P ar ts Diagr am - Steel                              EVOLUTION - Steel Components May 2007[...]

  • Page 30

    30 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF DEALER: _________________________________________ ADDRESS: _________________________________________ ____[...]