Enerco MH35FA manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Enerco MH35FA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enerco MH35FA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Enerco MH35FA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Enerco MH35FA should contain:
- informations concerning technical data of Enerco MH35FA
- name of the manufacturer and a year of construction of the Enerco MH35FA item
- rules of operation, control and maintenance of the Enerco MH35FA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enerco MH35FA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enerco MH35FA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enerco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enerco MH35FA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Enerco MH35FA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    04/0 4 R evision L1 #7 00 36 ENER CO GR OUP , Inc., 4 560 W . 1 60TH ST ., CLEVELAND, OHIO 4 4 1 3 5 • 2 1 6-88 1-5 500 If the informa tion in this manual is not follo wed e xactly , a fire or explosion ma y result causing proper ty damage, personal injur y or loss of life. W ARNING: — Do no t store or use gasoline or o ther flammable v apors a[...]

  • Page 2

    SPECIFIC A TIONS Type of Gas: .............................. For use with Propane Only Gas Supply Pressure to regulator ............................. Max: 200 psi (1380 kPa) Min: 20 psi (138 kPa) regulator out ........................... 10 psi (68.9 kPa) Electrical Input: .......................... 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 1[...]

  • Page 3

    OPERA TING PREC A UTIONS This is a pr opane, direct-fired, f or ced air heater . It's in tended use is primarily tempor ar y hea ting of buildings under construction, alter a tion or repair . Pr opane is hea vier than air . If propane leaks fr om a connection or fit ting, it sinks to the floor , collecting there with the surr ounding air , for[...]

  • Page 4

    ODOR F ADE W ARNING W ARNING Asphyxiation Hazard • Do not use this heater for heating human living quarters. • Do not use in unventilated areas. • The flow of combustion and ventilation air must not be obstructed. • Proper ventilation air must be provided to support the combustion air requirements of the heater being used. • Refer to the [...]

  • Page 5

    OPERA TING INSTRUC TIONS PREP ARING FOR OPERA TION 1 . Check the hea ter for possible shipping d amage. If any is found, immediately no tify the f actory . 2. Follo w all of the "Pr ecautions". 3. Connect the POL fit ting of hose and r egula tor assembly to the pr opane c ylinder b y r ota ting the POL nut counter clockwise into the propa[...]

  • Page 6

    REF.# ITEM# DESCRIPTION QTY. 13 8077 Fan Blade, 6.75 x .75 Pitch 1 14 2113 Power Cord Assembly 1 15 8136 Bushing Strain Relief 1 16 8116 Nut Hex 5-28 TE Valve 2 17 7161 Nut, Piezo 1 18 6473 Piezo Ignitor 1 19 7094 Clip Handle 2 20 7095 Handle 1 * M8494 Label, Model Warnings 1 * 70036 Label, Operating Instructions 1 * 8649 Manual, Operating Instruct[...]

  • Page 7

    SIZE AND C AP A CIT Y OF PR OP ANE CYLINDERS REQUIRED The char ts below sho w the appro ximate siz e of the c ylinder r equired f or these heaters. T o use the char t: 1 . Select the low est air temper atur e e xpected (at the bo t tom of the char t). 2. Mov e straigh t up to time of oper ation desir ed (left side of char t). 3. R ead the c ylinder[...]

  • Page 8

    W ARNING: USE ONL Y MANUF A CTURER’S REPL A CEMENT P AR TS. USE OF ANY O THER P AR TS CO ULD CA USE INJUR Y OR DEA TH. REPL A CEMENT P AR TS ARE ONL Y A V AIL ABLE DIRE CT FR OM THE F A CT OR Y AND MUST BE INST ALLED B Y A Q U ALIFIED SERVICE A GENCY . P ARTS ORDERING INFORMA TION: PUR CHA SING: A ccessories ma y be pur chased at an y Mr . Hea te[...]