A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Enerco 3500DF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Enerco 3500DF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Enerco 3500DF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Enerco 3500DF should contain:
- informations concerning technical data of Enerco 3500DF
- name of the manufacturer and a year of construction of the Enerco 3500DF item
- rules of operation, control and maintenance of the Enerco 3500DF item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Enerco 3500DF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Enerco 3500DF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Enerco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Enerco 3500DF.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Enerco 3500DF item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPERA TING INSTRUC TIONS AND O WNER’S MANU AL READ INSTRUC TIONS C AREFULL Y: R ead and f ollow all instructions. Pla ce instructions in a safe pla ce f or future r efer ence. Do not allo w an yone who has no t r ead these instructions to assemble, ligh t, adjust or oper a te the hea ter . MO DE L MO DE L 3500DF 6000DF 3500DF 6000DF 07/11 Rev A 5[...]

  • Page 2

    2 ENER CO GRO UP , INC. |Direct Fired P or table Heater Opera ting Instructions and Owner’s Manual W ARNING: FIRE, BURN, INHAL A TION, AND EXPL OSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MA - TERIALS, P APER OR CARDBO ARD, A SAFE DIST ANCE A W A Y FR OM THE HEA TER AS RE COMMENDED B Y THE INSTR UCTIONS NEVER USE THE HEA TER IN SP A C[...]

  • Page 3

    3 Opera ting Instructions and Owner’s Manual ENER CO GRO UP , INC. |Direct Fired P or table Heater TECHNIC AL SPECIFIC A TIONS MH3500 DF HS 35 00DF MH 6000DF HS 6000DF Hea t input [kB TU/h] 360 600 Air Flo w [cfm] 1795 2.800 Fu el T ype Diesel/K erosene/#1-2 Fu el Oil Hea t output [kB TU/h] - - Fu el consumption [gal/h] 2..6 4.32 [lb/h] 18.56 30.[...]

  • Page 4

    4 ENER CO GRO UP , INC. |Direct Fired P or table Heater Opera ting Instructions and Owner’s Manual Models X Y Z 35 00 DF 0.1 5 7 in 0.098 in 0.1 5 7 in 6000 DF 0.1 5 7 in 0.098 in 0.1 5 7 in • the roo m wh er e th e he at er is op er at ed. • The air inle t and outl et must n eve r b e blo cked for any reason. • • W ARNING • DO NO T USE[...]

  • Page 5

    5 Opera ting Instructions and Owner’s Manual ENER CO GRO UP , INC. |Direct Fired P or table Heater The ho t air gener a tors with wheels must be wheeled. The suspended v ersion which has no wheels must be tr anspor ted with adequ a te machinery . MAINTENANCE Pre ven tive and regular main tenance will ensure a long tr ouble free life t o your hea [...]

  • Page 6

    6 ENER CO GRO UP , INC. |Direct Fired P or table Heater Opera ting Instructions and Owner’s Manual TR OUBLESHOOTING TR OUBLE C A USE SOL UTION Motor does not star t, no ignition No electrical curren t Check mains (should be 1 2 0 V – 1~ – 60 Hz) Check pr oper positioning and functioning of swit ch Check fuse W r ong setting of room ther - mos[...]

  • Page 7

    7 Opera ting Instructions and Owner’s Manual ENER CO GRO UP , INC. |Direct Fired P or table Heater WIRING DIA GRAM 3500 SERIES MODELS FU Fuse 20A IT T rans former H . V. LI1 O ve rheat T hermo stat EV 1 So lenoi d Valve 1 ° FO Photo cell CO Co nd enser MV Fan Motor ST Elec tr ic pil ot RV Control T A Room T her most at RE Relays AP Control B ox [...]

  • Page 8

    PL 10/07 25 27 29 03 A 05 08 09 46 17 10 06 30 12 20 1 1 57 19 33 32 45 18 22 23 21 19 24 26 28 35 31 36 44 42 85 14 82 84 83 76 75 B 65 66 67 69 68 51 52 53 56 58 63 64 59 90 77 78 76 70 72 74 71 73 79 91 92 93 94 95 96 3500DF 100 98 99 101 94 102 01 103 16 14 17 14 13 86 108 107 87 106 104 105 14 16 14 A 33 B Optional 15 8 Opera ting Instructions[...]

  • Page 9

    HS-MH3500DF Heater Parts List BM2 NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION 01 40493 G06408-9010 Outlet Cone 59 50319 E10930 Transformer HT BRHAMA 03 50446 G06230 Combustion Chamber 63 50320 E40124 Control Box BRAHMA 05 50447 G06233-9010 Upper Body 64 50014 G06073 Plate for Elect. Components 06 40494 G06409-9010 Lower Body 65 50013 E10102[...]

  • Page 10

    PL 10/07 25 27 29 03 A 05 15 08 09 46 17 10 06 01 04 30 12 20 1 1 16 14 17 14 13 57 19 33 32 45 18 22 23 21 19 24 26 28 35 31 36 44 42 86 87 07 85 14 82 84 83 76 75 B 65 66 67 69 68 51 52 53 56 58 63 64 59 90 77 78 76 70 72 74 71 73 79 91 92 93 94 95 96 6000DF 100 98 99 101 94 102 A 15 33 B 10 Opera ting Instructions and Owner’s Manual ENER CO GR[...]

  • Page 11

    HS6000DF SERIES DIRECT FIRED HEATER PARTS LIST 2011 Ref. # Part # BM2 # Discription Ref. # Part # BM2 # Discription 01 50027 G06139-9010 Outlet cone 53 50092 E10313 Fuse 20A 03 50460 G06232 Combustion chamber 56 50096 E20319 Terminal board 04 50037 G06143-9010 Protection 57 50097 E11125 Relay 05 50461 G06235-9010 Upper Body 58 50098 E20305 Terminal[...]

  • Page 12

    12 ENER CO GRO UP , INC. |Direct Fired P or table Heater Opera ting Instructions and Owner’s Manual OPERA TING INSTRUC TIONS AND O WNER’S MANU AL READ INSTRUC TIONS C AREFULL Y: R ead and f ollow all instructions. Pla ce instructions in a safe pla ce for futur e r efer ence. Do not allo w an yone who has no t r ead these instructions to assembl[...]

  • Page 13

    MODÈLE LISEZ SOIGNEUSEMENT LES INSTRUC TIONS : Lisez e t obser v ez toutes les instructions. Conservez les instructions pour v ous y référer ultérie uremen t. In terdisez à quiconqu e n’ay an t pas lu les présen tes instructions d’assembler , d’allumer , de régler ou de f aire f onctionner cet appar eil de chauffage. GUIDE D’UTILISA [...]

  • Page 14

    HS6000DF SERIES DIRECT FIRED HEATER PARTS LIST 2011 Ref. # Part # BM2 # Discription Ref. # Part # BM2 # Discription 01 50027 G06139-9010 Outlet cone 53 50092 E10313 Fuse 20A 03 50460 G06232 Combustion chamber 56 50096 E20319 Terminal board 04 50037 G06143-9010 Protection 57 50097 E11125 Relay 05 50461 G06235-9010 Upper Body 58 50098 E20305 Terminal[...]

  • Page 15

    PL 10/07 25 27 29 03 A 05 15 08 09 46 17 10 06 01 04 30 12 20 1 1 16 14 17 14 13 57 19 33 32 45 18 22 23 21 19 24 26 28 35 31 36 44 42 86 87 07 85 14 82 84 83 76 75 B 65 66 67 69 68 51 52 53 56 58 63 64 59 90 77 78 76 70 72 74 71 73 79 91 92 93 94 95 96 6000DF 100 98 99 101 94 102 A 15 33 B 10 Opera ting Instructions and Owner’s Manual ENER CO GR[...]

  • Page 16

    HS-MH3500DF Heater Parts List BM2 NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION 01 40493 G06408-9010 Outlet Cone 59 50319 E10930 Transformer HT BRHAMA 03 50446 G06230 Combustion Chamber 63 50320 E40124 Control Box BRAHMA 05 50447 G06233-9010 Upper Body 64 50014 G06073 Plate for Elect. Components 06 40494 G06409-9010 Lower Body 65 50013 E10102[...]

  • Page 17

    PL 10/07 25 27 29 03 A 05 08 09 46 17 10 06 30 12 20 1 1 57 19 33 32 45 18 22 23 21 19 24 26 28 35 31 36 44 42 85 14 82 84 83 76 75 B 65 66 67 69 68 51 52 53 56 58 63 64 59 90 77 78 76 70 72 74 71 73 79 91 92 93 94 95 96 3500DF 100 98 99 101 94 102 01 103 16 14 17 14 13 86 108 107 87 106 104 105 14 16 14 A 33 B Optional 15 8 Opera ting Instructions[...]

  • Page 18

    7 L e fait de F aire mar cher des Instructions et le Manu el de Propriétair e ENER CO GRO UP , INC. |Chauffage P ortatif Direct-tiré WIRING DIA GRAM FU Fusibl e 20A IT T rans form at eur H . T. LI1 Ther most at de surchauf fe EV 1 El ec trovanne 1° FO Ph otore si st ance CO Co nd ensateur MV Moteur du ventilator ST L ampe temo in d’ al imentat[...]

  • Page 19

    6 ENER CO GRO UP , INC. |Chauffage P or tatif Direct-tiré L e fait de F aire mar cher des Instructions et le Manu el de Propriétaire ANOMALIES DE FONC TIONNEMENT C A USES ET SOL UTIONS ANOMALIE DEFONC TIONNEMENT C AUSE SOL UTION Le v entilateur ne démarre pas et la flamme ne s’allume pas L e cour ant électriqu e n’arrive pas Vérifier les[...]

  • Page 20

    5 L e f ait de F aire mar cher des Instructions et le Manu el de Propriétair e ENER CO GRO UP , INC. |Chauffage P or tatif Direct-tiré sur chauffe: le thermosta t se réarme a utomatiqu ement qu and la tempér a ture de la chambre de combustion diminu e jusqu’à rejoindr e la vale ur maximale admise. A van t de reme t tre en mar che le génér [...]

  • Page 21

    4 ENER CO GRO UP , INC. |Chauage Portatif Direct-tiré L e fait de F aire mar cher des Instructions et le Manuel de Pr opriétaire Trou des electrodes • les Étag es et les p lafonds d oi t êt re fait du m at é ri el i gnifugé dans la piè ce où le chau  age es t fait ma rcher. • l’ a rr iv ée aé ri en ne et l ’ issue ne d oi t [...]

  • Page 22

    3 L e fait de F aire mar cher des Instructions et le Manu el de Propriétair e ENER CO GRO UP , INC. |Chauffage P ortatif Direct-tiré TECHNIC AL SPECIFIC A TIONS MH 35 00DF HS 35 00DF MH 6000DF HS 6000DF Puisance termiqu e en entrée [kB TU/h] 360 600 Débit d’air [cfm] 1795 2.800 T ype du Combustible L e gazole/Pétr ole / * 1-2 Fu el Puisance [...]

  • Page 23

    2 ENER CO GRO UP , INC. |Chauffage P or tatif Direct-tiré L e fait de F aire mar cher des Instructions et le Manu el de Propriétaire AVERTISSEMENT : DANGER D’INCENDIE, DE BR ÛLU RE , D’E XPL OSI ON ET D ’IN HAL ATI ON. CO NSE RVE Z LE S M ATÉ RIA UX CO MB UST IBL ES TEL S QU E LE S M ATÉ RI AU X D E C ONS TRU CT IO N, LE PAP IER E T LE C[...]

  • Page 24

    07/11 Rev A 50 1 25 ENER CO GRO UP , INC., 4 560 W . 1 60TH ST ., CLEVELAND, OHIO 4 4 1 3 5 • 800- 2 5 1-00 0 1 DIREC T TIRÉ CHA UFF A GE POR T A TIF Si le s i nf or ma ti ons dans ce m anuel ne s ont p as s u ivi s e x a cte m ent , un f eu ou u ne e xplo s ion pe u v ent s’ensu i vre en p r o v oq u ant le do m ma ge de pr opr i été , l a [...]