Empire Comfort Systems VFFB-42D manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Empire Comfort Systems VFFB-42D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Empire Comfort Systems VFFB-42D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Empire Comfort Systems VFFB-42D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Empire Comfort Systems VFFB-42D should contain:
- informations concerning technical data of Empire Comfort Systems VFFB-42D
- name of the manufacturer and a year of construction of the Empire Comfort Systems VFFB-42D item
- rules of operation, control and maintenance of the Empire Comfort Systems VFFB-42D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Empire Comfort Systems VFFB-42D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Empire Comfort Systems VFFB-42D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Empire Comfort Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Empire Comfort Systems VFFB-42D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Empire Comfort Systems VFFB-42D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    R-5010 1 UNIVERSAL FIREPLA CE FOR ALL VENT -FREE LOG SYSTEMS MODELS: VFFB-36D Non-Circulating - Blac k Hood VFFB-42D Non-Circulating - Blac k Hood Effective Date April, 2001 W ARNING: If the information in this man ual is not f ollowed exactl y , a fire or explosion ma y result causing property damage, personal injury or loss of life. WHA T T O DO [...]

  • Page 2

    R-5010 2 The installation must conf orm with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) and to the National electrical Code, ANSI/NFP A70 (latest edition). NO TE: Installation and repair should be done b y a qualified service person. The appliance should be inspected before use and [...]

  • Page 3

    R-5010 3 Fig. 1. Clearances to combustibles. 1. CLEARANCES. Sidewall Clearances: The clearance from the inside of the fireplace to any combustible wall should not be less than 6”. Fireplace Side and Bac k Clearances: The fireplace outer casing sides and back have zero clearance to combustibles. Ceiling Clearances: The ceiling height should not be[...]

  • Page 4

    R-5010 4 C INST ALLA TION INSTRUCTIONS. In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned at this time. The fireplace can be mounted on any of these surfaces: 1. A flat hard combustible or non-combustib[...]

  • Page 5

    R-5010 5 Fig. 3. Fireplace dimensions. C-2. LOCA TING FIREPLA CE. Place fireplace in framing opening. Using the four (4) nailing tabs provided on the fireplace, attach two (2) tabs on each side. Attach tabs through prepunched holes. Additional hole locations will be used for different finishing material with thicknesses of 1/2”, 5/8” and 3/4”[...]

  • Page 6

    R-5010 6 C-3. CONNECTING THE GAS LINE. The fireplace is designed to accept a 3/8-inch gas line for an approved gas fireplace. Have the line installed by a qualified service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the 3/8-inch hook-up at the unit. Gas access holes are[...]

  • Page 7

    R-5010 7 C-5. ELECTRICAL CONNECTION. The VFFB36/42D with optional fan requires 120 V AC electrical hookup to the electrical box (installed). CA UTION: ALL WIRING SHOULD BE DONE BY A QU ALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND ST A TE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THA T MAIN PO WER [...]

  • Page 8

    R-5010 8 Attach the cover plate behind the bottom louver with four (4) screws, provided to the support legs on the back left side of the firebox, as shown in Fig. 9. Attach the (2) screws for damper rod bracket to the bottom of the hearth pan, while holding the damper rod bracket with the flange facing the rear of the unit. Connect damper assembly [...]

  • Page 9

    R-5010 9 C-7. INST ALLING THE HOOD . A black hood is furnished with each model VFFB36/42D fireplace and MUST be installed before the fireplace is used. Failure to do so may create a possible fire hazard. If brass hoods are desired, they can be purchased as an option. Attachment is the same, as our standard black hood. 1. Remove the one top screw an[...]

  • Page 10

    R-5010 10 F MAINTENANCE. Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing area at least twice a year . THE LOGS CAN GET VER Y HOT – HANDLE ONL Y WHEN COOL. Always turn off gas to the pilot before cleaning. For relighting, refer to lighting instructions located on the rating plate of the log se[...]

  • Page 11

    R-5010 11 The following accessory parts can be obtained from your Empire Comfort Systems, dealer . Should you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems, Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62222-0529. Accessory Description Model No. Fan Kit Designed to provide forced air flow[...]

  • Page 12

    R-5010 12 H REPLA CEMENT P AR TS. Contact the factory for questions concerning prices and policies covering these replacement parts. Parts will be shipped at prevailing prices. Normally , all parts can be ordered through your Empire Comfort Systems, Inc. distributor or dealer . When ordering repair parts, always give the following information: 1. T[...]

  • Page 13

    R-5010 13 H REPLA CEMENT P AR TS. Contact the factory for questions concerning prices and policies covering these replacement parts. Parts will be shipped at prevailing prices. Normally , all parts can be ordered through your Empire Comfort Systems, Inc. distributor or dealer . When ordering repair parts, always give the following information: 1. T[...]

  • Page 14

    R-5010 14 INSTALLING OPTIONAL LOUVER Attention: Remove protective film on brass louver before installation. Attention: The optional top louver has (4) mounting tabs. The optional bottom louver has (2) clearance holes. 1. Remove (2) Phillips screws that attach upper, panel front to casing top. 2. At the top, leading edge of upper, panel front push d[...]

  • Page 15

    R-5010 15 Service Notes[...]

  • Page 16

    R-5010 16 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 PH: 1-800-851-3153 F AX: 1-800-443-8648 E-MAIL: empire@accessus.net WEB SITE: www .empirecomfort.com[...]