Empire Comfort Systems CIDV-30-7 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Empire Comfort Systems CIDV-30-7, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Empire Comfort Systems CIDV-30-7 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Empire Comfort Systems CIDV-30-7. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Empire Comfort Systems CIDV-30-7 should contain:
- informations concerning technical data of Empire Comfort Systems CIDV-30-7
- name of the manufacturer and a year of construction of the Empire Comfort Systems CIDV-30-7 item
- rules of operation, control and maintenance of the Empire Comfort Systems CIDV-30-7 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Empire Comfort Systems CIDV-30-7 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Empire Comfort Systems CIDV-30-7, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Empire Comfort Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Empire Comfort Systems CIDV-30-7.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Empire Comfort Systems CIDV-30-7 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Page 1 R-5086 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON DIRECT VENT FIREPLACE MODEL CIDV-30-7 EFFECTIVE DATE AUGUST, 2000 FOR YOUR SAFETY: What to do if you smell gas: • Do not touch any electrical switches • Do not try to light any appliance. • Do not use the phone in your building. • Immediately call your gas supplier [...]

  • Page 2

    Page 2 R-5086 Specifications Model CIDV-30 Input BTU/HR (KW/H) Max (LP/NAT) 30,000 (8.7) BTU/HR (KW/H) Min. LP 22,000 (6.4) BTU/HR (KW/H) Min. Nat. 19,500 (5.7) Height 27 3/4" (70.5cm) Width 25 1/2" (64.8cm) Depth 23" (58.4cm) Gas Inlet (Pipe) 1/2" (13mm) Floor to top of collar on vertical 27 5/8" (70.2cm) position of Vent [...]

  • Page 3

    Page 3 R-5086 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Some- times other odors in the area[...]

  • Page 4

    Page 4 R-5086 Installation in Residential Garages Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18" (457mm) above the floor. Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle. Qualified Instal[...]

  • Page 5

    Page 5 R-5086 Figure 1 Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System 1. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. 2. The appliance and its[...]

  • Page 6

    Page 6 R-5086 Appliance Hardware Package (Figure 6) Figure 6 Appliance Hardware Package Parts List Part Part Quantity Description Number Supplied 1/4-20 x 1" Phillips Head Bolt R-3188 4 1/4-20 x 3/8" Phillips Head Bolt R-3646 16 1/4-20 x 1/2" Leveling Bolt R-3747 4 No. 10 x 1/2" R-2737 8 Hex Washer Head Screw 1/4-20 Washer Head [...]

  • Page 7

    Page 7 R-5086 to protect the porcelain finish. The exterior of the porcelain casting pieces should be facing the non-abrasive surface. 2. The assembly of the casting is accomplished in 6 stages: A. Attaching legs to the sides (Figure 7). B. Attaching rear cover to sides (Figure 8). C. Removing protective packaging from casing front and window (Figu[...]

  • Page 8

    Page 8 R-5086 8. Position the completed portion of the casing in the approximate location for installation as the completed assembly will be heavy. 9. Refer to Figure 9, removing protective packing foam from casing front and window. Remove the (1) 3/4" bolt and (1) 1/4" washer from top of window. Remove (1) 3/8" bolt and 1 - 5/8"[...]

  • Page 9

    Page 9 R-5086 15. Attach casing front to outer casing as described in Step 11. 16. Place the casing top onto the outer casing. The casing top nests into the outer casing. 17. Insert center grille, left grille and right grille into casing top. Figure 11[...]

  • Page 10

    Page 10 R-5086 Delayed Ignition Reset Switch Assembly (Figure 14) Attach black wire from REMOTE/OFF/ON switch to the front 1/4" male tab on the reset switch. Attachment of black wire onto the reset switch is done in conjunction with the preceding steps for Installation of Wire Channel Assembly. Black wire on the back of the reset switch is att[...]

  • Page 11

    Page 11 R-5086 Venting Graph (Dimensions in Feet) (Figure 16) 1. Determine the height of the center of the termination. Using this dimension on the Venting Graph, locate the point it intersects with the slanted graph line, or the right edge of the graph. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Adj[...]

  • Page 12

    Page 12 R-5086 Installation of Restrictor Plate (Figure 18) The restrictor plate is to be used only in a completely vertical vent installation. The restrictor plate can be used when the vertical vent rise is between 10 feet and 25 feet. In a vertical vent rise the rear (yellow) flame on the main burner can be reduced due to the drawing action from [...]

  • Page 13

    Page 13 R-5086 Termination Clearances (Figure 19) Termination clearance for buildings with combustible and noncombustible exteriors. Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is one inch (1") (25mm) on, bottom and sides and (2") (51mm) on top. Important! When vent termination[...]

  • Page 14

    Page 14 R-5086 Figure 20 A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] B = clearance to window or door that may be opened [*9 inches (23cm) minimum for appliances < 50,000 Btuh (14.6kW) C = clearance to permanently closed window [minimum 12 inches (30cm) recommended to prevent condensation on window] D =[...]

  • Page 15

    Page 15 R-5086[...]

  • Page 16

    Page 16 R-5086 Figure 23 Installing Firestops (Figures 24, 25, 26 and 27) Firestops are required for safety whenever the vent system passes through an interior wall, an exterior wall, or a ceiling. These firestops act as a firebreak heat shield and as a means to insure that minimum clearances are maintained to the vent system. Horizontal runs in th[...]

  • Page 17

    Page 17 R-5086 Figure 27 Horizontal Terminations (Figure 28) Attach and secure the termination to the last section of horizontal venting by rotating and interlocking the ends as previously described. NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior positi[...]

  • Page 18

    Page 18 R-5086[...]

  • Page 19

    Page 19 R-5086 Vertical runs of this vent systems must be supported every 4 feet above the appliance flue outlet by wall brackets attached to the 6- 5/8 inch vent pipe and secured with nails or screws to structural framing members.[...]

  • Page 20

    Page 20 R-5086 Replacement of Gasket on Glass Panes (Figure33) 1. Remove casing top from outer casing. 2. Remove casing front from outer casing. 3. Lower valve cover on firebox. 4. Release two door latches at bottom of firebox. 5. Grasp bottom of glass frame, pull forward until bottom of glass frame is removed from glass frame guide and pull downwa[...]

  • Page 21

    Page 21 R-5086 Main Burner Flame Pattern (Figure 36 and Figure 37) Figure 36 shows a correct main burner flame pattern. Figure 37 shows an incorrect main burner flame pattern. Air Shutter Adjustment An air shutter adjusting screw is located on the exterior, bottom of the inner body. Screw air shutter adjusting screw IN to close air shutter top (inc[...]

  • Page 22

    Page 22 R-5086 Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall Thermostat Accessory and Another Accessory Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the 750 millivolt wall thermostat AND to the remote receiver that is a component in the FRBC-1, FREC-1 OR to the FWS-1, wall switch. 1. Conn[...]

  • Page 23

    Page 23 R-5086 Initial Lighting (Figure 40) Upon completing the gas line or turning the gas valve "ON" after it has been in the "OFF" position, a small amount of air will be in the lines. When first lighting the appliance, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the[...]

  • Page 24

    Page 24 R-5086 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all a[...]

  • Page 25

    Page 25 R-5086 ST ANDING PILOT -TROUBLE SHOOTING With proper installation and maintenance, your new Direct Vent Fireplace should provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to[...]

  • Page 26

    Page 26 R-5086 How To Order Repair Parts ... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number. When ordering parts, first obtain[...]

  • Page 27

    Page 27 R-5086 19 29 30[...]

  • Page 28

    Page 28 R-5086[...]

  • Page 29

    Page 29 R-5086 OPTIONAL BLOWER CIB-2 Dir ect V ent Fir eplace CIDV -30 I nstalling Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the [...]

  • Page 30

    Page 30 R-5086 PARTS LIST Index Part No. No. Description 1 R-1454 Brass Bushing (4 Required) 2 R-1499 Rubber Grommet (4 Required) 3 CI-002 Blower Housing 4 R-1517 Tinnerman Clip (4 Required) 5 R-2804-A Blower Assembly 6 CI-003 Blower Housing Cover 7 R-2099 Cord Set 8 R-3767-A Wire Harness 9A CI-004 Fan Control Bracket (Use with CIBV-30, CIVF-25, CI[...]