A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF960WB 00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF960WB 00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF960WB 00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF960WB 00 should contain:
- informations concerning technical data of Emerson CF960WB 00
- name of the manufacturer and a year of construction of the Emerson CF960WB 00 item
- rules of operation, control and maintenance of the Emerson CF960WB 00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF960WB 00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF960WB 00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF960WB 00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF960WB 00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP72680001 Form No. BP7268-1 READ AND SA VE THESE INSTRUCTIONS WINDJAMMER ™ ® Net Weight: 27.6 Lbs. Ceiling Fan Owner's Manual LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must b[...]

  • Page 2

    2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2 . Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on [...]

  • Page 3

    1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One light fixture assembly c. Six fan blades d. Six blade flanges e. One ceiling cover f. One hanger ball/downrod assembly g. One hanger bracket h. One coupling cover i. One light [...]

  • Page 4

    5. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 4). 6. Reinstall the hanger ball (Figure 5) on the downrod as foll[...]

  • Page 5

    7. The fan comes with blue, black and white leads that are 80” long. Before installing the fan, measure up approximately 6 to 9-inches above the top of hanger the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from the end of leads. 8. Your new ceiling fan will require a grounded 120 volts AC, 60 Hz, 15 amp electri[...]

  • Page 6

    3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 9). 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10). 5. Secure the ceiling cover in place by sliding #8 lockwashers over the threaded studs and installing the two knurled [...]

  • Page 7

    7 To avoid possible fire or shock, make sure that the electrical wires are not pinched between the light fixture assembly and the mounting plate. W ARNING ! 3. Partially install two 3/16-24 x 1/4” Phillips round head screws in two of the tapped holes in the coupling adapter (Figure 13). Leave two or three threads untightened. 4. Position the keyh[...]

  • Page 8

    8 Installation of Light Adapter Plate NOTE: In order to use the light adapter plate (supplied), the wiring harness included as part of the light fixture assembly must be removed and be reinstalled in the light adapter plate. This Section contains the procedures to accomplish this. 1. Disconnect the light fixture connector from the wiring harness co[...]

  • Page 9

    9 Using Y our Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the speed control pull chain switch (Figure 23). The operating sequence is as follows: THREE-SPEED 1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF 3. If ai[...]

  • Page 10

    10 WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan. 2. Check line wir[...]

  • Page 11

    13 26 27 14 28 16 17 15 24 20 9 19 18 3 1 5 4 6 7 8 2 21 25 23 22 12 11 10 11 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-80[...]

  • Page 12

    Part No. F40BP72680001 Printed in Taiwan 05/03 Form No. BP7268-1 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W. Florissant ¥ St. Louis, MO 63136 Repair Par ts Listing Model No. Key N o . Description CF960CK00 CF960WB00 CF960BS00 * Hanger Ball Assembly , 761655-23 761655-20 761655-17 Consisting of: 1 Hanger Bracket — — — 2 Hanger Ba[...]