Emerson CF750ORB00 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF750ORB00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF750ORB00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF750ORB00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF750ORB00 should contain:
- informations concerning technical data of Emerson CF750ORB00
- name of the manufacturer and a year of construction of the Emerson CF750ORB00 item
- rules of operation, control and maintenance of the Emerson CF750ORB00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF750ORB00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF750ORB00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF750ORB00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF750ORB00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP73330000 Form No. BP7333 UL Model No.: CF750 READ AND SA VE THESE INSTRUCTIONS Net Weight: 28.6 Lbs. MA Y A ZEN ™ 54” Ceiling Fan Owner's Manual CF750ORB00 Model No. BP7333 CF750 MAYA ZEN 12/22/06 7:59 AM Page 1[...]

  • Page 2

    W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental[...]

  • Page 3

    3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-800-654-3545 ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifica[...]

  • Page 4

    4 2. Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly . 3. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. J. HANGER BRACKET HI MED LOW FAN OFF EMERSON D/L U/L LIGHT A. F AN MOTOR ASSEMBL Y C. CEILING COVER G. LIGHT PLA TE A[...]

  • Page 5

    5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. IMPORT ANT : Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of W all Control and Receiver” and “Ba[...]

  • Page 6

    F AN MOTOR ASSEMBL Y 6 - 8 INCHES STYROFOAM P ACKAGING FLA T EDGE OF LIGHT KIT PLA TE ASSEMBL Y STYROFOAM M4 x 10mm SERRA TED HEAD SCREW (3) KEY HOLE SLOT (2) MOUNTING HOLE (1) LIGHT KIT ASSEMBL Y F AN MOTOR ASSEMBL Y Figure 2 T o reduce the risk of personal injury , do not bend the blade flange when installing the blade flanges, balancing the blad[...]

  • Page 7

    10. Unscrew and remove one lockwasher and screw from each end of the upper light plate cover on the fan motor housing. Do not remove the screw closest to the light holes (Figure 9). NOTE: The screw closest to the light holes, holds the light socket to the light plate cover . Do not remove this screw. 11 . Pull up on the upper light plate cover to e[...]

  • Page 8

    8 CEILING COVER PIN DOWNROD HANGER BALL SETSCREW Figure 14 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. ! W ARNING 16. Reinstall the hanger ball (Figure 14) on the downrod as follows. Route[...]

  • Page 9

    1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 16). How to Hang Y our Ceiling Fan The fan must be hung with at least 7' of clearance from floor to blades (Figure 15). ! W ARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use onl[...]

  • Page 10

    OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE CONNECTOR RECEIVER WHITE SUPPL Y WIRE SUPPL Y GROUND WIRE (GREEN OR BARE) HANGER BALL GROUND WIRE (GREEN) HANGER BRACKET GROUND WIRE (GREEN) HANGER BRA[...]

  • Page 11

    11 Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result. ! W ARNING BLUE RECEIVER WIRE YELLOW RECEIVER WIRE BLUE F AN WIRE DOWNROD BLACK F AN WIRE SW105 RECEIVER WHITE F AN WI[...]

  • Page 12

    5. Unscrew the finial nut, hex jamnut, and rubber lockwasher from the light kit threaded nipple (Figure 22). Retain the lockwasher , hex jamnut and finial nut for future installation. 6. Position the glass shade over the threaded nipple in the light kit plate assembly (Figure 23). Seat the glass shade evenly over the plate assembly and securely ins[...]

  • Page 13

    ON 1 234 RECEIVER SWITCH LEVERS CODE SWITCH SW105 RECEIVER CODE SWITCH WALL CONTROL WALL CONTROL LEVERS ON 1 234 LIGHT HI HI MED MED LOW LOW FAN OFF T urning off wall switch is not sufficient. T o avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box. ! W ARNING 13 Battery Installation of W all C[...]

  • Page 14

    4. T o turn the lights on and off, press and release the upper part of the LIGHT (U/L) button or the lower part of the LIGHT (D/L) button. The lights will turn on at the light level previously set (see Step 3). Red light turns on when any button is pressed. If the light does not come on, replace your battery . 5. If airflow is desired in the opposi[...]

  • Page 15

    15 1. Downrod Extension Kits (see store or catalog). 2. Ceiling Fan Controls (see store or catalog). 3. Blades (see store or catalog). Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this [...]

  • Page 16

    16 Repair Parts 4 24 HI MED LOW FAN OFF EMERSON D/L U/L LIGHT 29 1 7 8 9 6 3 2 15 16 17 28 5 21 22 25 13 14 23 18 30 10 27 26 11 12 20 19 BP7333 CF750 MAYA ZEN 12/22/06 7:59 AM Page 16[...]

  • Page 17

    Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545. • P ART NUMBER • NAME OF ITEM • P ART DESCR[...]

  • Page 18

    18 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan. to fan. 3. Fan/Light W all Control is OFF. 3. T ur[...]

  • Page 19

    LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this war[...]

  • Page 20

    Part No. F40BP73330000 Printed in China 12/06 Form No. BP7333 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 BP7333 CF750 MAYA ZEN 12/22/06 7:59 AM Page 20[...]