Emerson CF703PB02 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF703PB02, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF703PB02 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF703PB02. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF703PB02 should contain:
- informations concerning technical data of Emerson CF703PB02
- name of the manufacturer and a year of construction of the Emerson CF703PB02 item
- rules of operation, control and maintenance of the Emerson CF703PB02 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF703PB02 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF703PB02, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF703PB02.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF703PB02 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Ceiling Fan Owner's Manual READ AND SA VE THESE INSTRUCTIONS ® by Part No. F40BP708300007 Form No. BP7083-7 42" Model No. CF704W02 CF704WPB02 CF704PB02 CF704WW02 CF704AB02 CF704A W02 Net Weight: 1 1.1 Lbs. 36" Model No. CF703WW02 CF703PB02 29" Model No. CF702WW03 CF702PB03 Net Weight: 1 1.1 Lbs. Net W eight: 10.5 Lbs. LIMITED W[...]

  • Page 2

    2 DATE CODE: The date code of this fan may be found on the box, stamped in ink on a white label. Y ou should record this data above and keep it in a safe place for future use. W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for [...]

  • Page 3

    T ools Needed for Assembly One Phillips head screwdriver One stepladder One 1/4" blade screwdriver One wire stripper Three wire connectors (supplied) MA TERIALS Wiring outlet box and box connectors must be of type required by local code. The minimum would wire be a 3-conductor (2-wire with ground) of the following size: Installed Wire Length W[...]

  • Page 4

    4 2. Remove the three switch cup screws from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 2). 3. Pass the 80" motor leads through the opening in [...]

  • Page 5

    5 How to Hang Y our Ceiling Fan A T LEAST 7' CEILING FLOOR Figure 6 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . Figure 8 Figure 7 Electrical Requir ements If your fan is to replace an existing [...]

  • Page 6

    Using Y our Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the re- versing switch positioned to circulate air downward. If airflow is desired in opposite direction[...]

  • Page 7

    WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Reversing switch in neutral position. 1. Make sure reversing switch position is all the start. way to one side. 2. Fuse or circuit breaker blown. 2. Check main and[...]

  • Page 8

    Repair Parts Listing (CF704 Series) Part Number Key Model No. Model No. Model No. Model No. Model No. Model No. N o . Description CF704W02 CF704WW02 CF704PB02 CF704AB02 CF704WPB02 CF704AW02 • Hanger Ball Assembly, Consisting of: 760750-2 760750-3 760750-1 760750 760750-3 760750-41 1 Hanger Bracket – – – – – – 2 Hanger Ball – – –[...]