Emerson CF654AW00 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF654AW00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF654AW00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF654AW00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF654AW00 should contain:
- informations concerning technical data of Emerson CF654AW00
- name of the manufacturer and a year of construction of the Emerson CF654AW00 item
- rules of operation, control and maintenance of the Emerson CF654AW00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF654AW00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF654AW00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF654AW00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF654AW00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP73360000 Form No. BP7336 U.L. Model No.: CF653 READ AND SA VE THESE INSTRUCTIONS Model No. CF654A W00 CF654OB00 CF654ORB00 CF654WB00 CF654WW00 WET LOCA TION Net W eight: 18.7 Lbs. 52” Ceiling Fan Owner's Manual ENERGY ST AR[...]

  • Page 2

    2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally[...]

  • Page 3

    T ools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Three wire connectors (supplied). MA TERIALS Wiring, electrical box and box connectors must be of type required by the local code. The minimum wiring would be a 3-conductor (2-wire with ground) of follow- ing sizes: Installed Wire Length Wire Size A.W.G. Up to[...]

  • Page 4

    How to Put Y our Ceiling Fan T ogether 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5. 2. Unscrew the two upper setscrews (Figure 2) until they cle[...]

  • Page 5

    Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds. If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing l[...]

  • Page 6

    1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 8). A T LEAST 7' CEILING FLOOR How to Hang Y our Ceiling Fan Figure 7 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 8 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y Figure 9 2. Carefully lift t[...]

  • Page 7

    3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 11). 5. Secure the ceiling cover in place by sliding lockwash- ers over the threaded studs and installing the two knurled knobs (suppl[...]

  • Page 8

    1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. 4. If airflow is desired in opposite direction, turn your [...]

  • Page 9

    T r ouble Shooting W ARNING: FOR YOUR OWN SAFETY TURN OFF POWER A T FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR F AN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Reversing switch in neutral position. 1. Make sure reversing switch position is all the way to one side. 2. Fuse or circuit breaker blown. 2. Check main [...]

  • Page 10

    2 1 1 9 9 9 5 9 9 9 8 9 9 9 3 6 7 9 4 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER The model number of your Fan will be found on a label attached to th[...]

  • Page 11

    Repair Parts Listing Key Service Part No. N o . Description CF654WW01 CF654OB00 CF654WB00 CF654AW00 CF654ORB00 1 Hanger Assembly 761655 761655-9 761655-20 761655-21 761655-32 2 Ceiling Cover 760169 760169-24 760169-30 760169-32 760169-41 3 Blade Set (5) 762004 762004-1 762004-5 762004-4 762004-6 4 Flange Set (5) 763116-WW 763116-OB 763116-WB 763116[...]

  • Page 12

    Part No. F40BP73360000 Form No. BP7336 Printed in China 11/06 Air Comfort Products DIVISION OF Emerson Electric Co. 8100 W. Florissant ¥ St. Louis, MO 63136 LIMITED W ARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials[...]