Emerson CF130BS00 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson CF130BS00, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson CF130BS00 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson CF130BS00. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson CF130BS00 should contain:
- informations concerning technical data of Emerson CF130BS00
- name of the manufacturer and a year of construction of the Emerson CF130BS00 item
- rules of operation, control and maintenance of the Emerson CF130BS00 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson CF130BS00 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson CF130BS00, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson CF130BS00.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson CF130BS00 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. F40BP74040000 Form No. BP7404 UL Model No.: CF130 READ AND SA VE THESE INSTRUCTIONS Net Weight: 10.6 Lbs. Damp Loca tion 30” Mini Ceiling F an Owner's Manual CF130BS00 Br ushed Steel CF130ORB00 Oil Rubbed Bronze CF130WW00 Appliance W hite Model Number s: TIL O ™ BP7404 Tilo 12/16/09 4:06 PM Page 1[...]

  • Page 2

    WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental[...]

  • Page 3

    3 THIS F AN IS SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS... ANYWHERE THERE IS A ROOF OVERHEAD. This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-8[...]

  • Page 4

    4 2. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. B. HANGER BRACKET C. 4.5" DOWNROD ASSEMBL Y D. CEILING COVER F . COUPLER COVER H. SWITCH HOUSING G. FAN BLADES (3) E. DECORA TIVE LOWER COVER A. FAN MOTOR ASSEMBL Y J. LOOSE PAR TS BAG 4 0 3 2 1 I . SW46 WALL CONTROL NOTE: Pla[...]

  • Page 5

    Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. T o reduce the risk of fire, electric shock, or personal injury , mount fan to outlet box marked “Acceptable for Fan Support”, and use scr[...]

  • Page 6

    6 UL Model No.: CF130 1. Carefully turn the partially assembled ceiling fan right side up and place the fan securely into the packing sytrofoam in preparation for final assembly . 2. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 4). Remove the pin from the downrod, then remo[...]

  • Page 7

    7 UL Model No.: CF130 HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING COUPLER COVER GROMMET DOWNROD SETSCREW (2) Figure 6 4. While pulling up on the downrod, securely tighten the two setscrews in the motor coupling (Figure 6). NOTE: The setscrews must be properly installed as described above, or fan wobble could result. 5. Make sure the grommet is properly [...]

  • Page 8

    1. Position the hanger bracket on the outlet box so that the T -slots in the hanger bracket are aligned with the outlet box screws (Figure 12). Installation of Hanger Brack et The fan must be hung with at least 7' of clearance from floor to blades (Figure 1 1). ! WARNING The outlet box and joist must be securely mounted and capable of supporti[...]

  • Page 9

    T urning off wall switch is not sufficient. T o avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. ! WARNING T o reduce the risk of fire, [...]

  • Page 10

    UL Model No.: CF130 10 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation) (Figure 16). Securely connect wires using wire connectors supplied. NOTE: When wiring the ceiling fan for close-to-t[...]

  • Page 11

    UL Model No.: CF130 NOTE: When installing the ceiling fan using the close-to-the-ceiling method, carefully lift the fan assembly from the hook on the hanger bracket and proceed as follows. 1. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box[...]

  • Page 12

    12 UL Model No.: CF130 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! WARNING Maintenance IMPORT ANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft br[...]

  • Page 13

    T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan. to fan. 2. Fan sounds 1. Blades not attached to fan. [...]

  • Page 14

    UL Model No.: CF130 14 Damp Part Numbers Key Model No. Model No. Model No. No. Description CF130BS00 CF130ORB00 CF130WW00 * Hanger Pack Consisting of: 762231-4 762231-8 762231-1 1 Hanger Bracket Assembly —— — 2 Hanger Ball —— — 3 Downrod, 4.5 ”— — — 4 Ceiling Cover 764029-BS 764029-ORB 764029-WW 5 Decorative Upper Cover (2) 7640[...]

  • Page 15

    R epair Par ts 16 17 10 8 20 13 9 18 7 19 1 21 22 3 2 4 6 12 4 0 3 2 1 11 14 15 5 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label attached to the top housing. For rep[...]

  • Page 16

    UL Model No.: CF130 Part No. F40BP74040000 Printed in China 12/09 Form No. BP7404 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W . Florissant • St. Louis, MO 63136 LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in wo[...]