Emerson 16C26S-010 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 16C26S-010, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 16C26S-010 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson 16C26S-010. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson 16C26S-010 should contain:
- informations concerning technical data of Emerson 16C26S-010
- name of the manufacturer and a year of construction of the Emerson 16C26S-010 item
- rules of operation, control and maintenance of the Emerson 16C26S-010 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 16C26S-010 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 16C26S-010, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 16C26S-010.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 16C26S-010 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    UST Universal Slim Twin Model Number 16C26S-010 OWNERS MANUAL • Installation • Operation • Basic UST Service Guide • T echnical Repair Guide • Repair Parts Part No. 37-6070A Replaces 846-2027 Rev B 0015 Electronic Air Cleaner Printed In U.S.A. UL Listed CSA Certified by White-Rodgers Please read and familiarize yourself with the contents [...]

  • Page 2

    2 RULES FOR SAFE INST ALLA TION AND OPERA TION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing. Failure to do so could result in serious personal [...]

  • Page 3

    3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B). Here each tiny particle receives a positive electrical charge. These c[...]

  • Page 4

    4 PREINST ALLA TION facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires). LOCATING THE AIR FILTER Your electroni[...]

  • Page 5

    5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation. Cleaner is mounted vertically, where return air enters [...]

  • Page 6

    6 INST ALLA TION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation. INSTALLATION The following is a typical installation of the air cleaner on a “[...]

  • Page 7

    7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation. Failure to do so could result in serious personal injury or death. 8. The ai[...]

  • Page 8

    8 An alternate method for controlling the air cleaner operation is to install an F859-0381 Air Flow Switch/ Harness Kit (available separately) that switches power to the air cleaner when airflow is detected. NOTE: The air cleaner should not be operating un- less the furnace blower is on. 11. With the cabinet Installed, reinstall pre-filter(s) and c[...]

  • Page 9

    9 3. Release the latch on top of power pack and pull the power pack straight away from cabinet at the top. Then lift pack out of ledge at bottom edge of cabinet. Set power pack aside. 4. Remove the cell(s) and pre-filter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) and pre-filter(s) for 20 to 30 minutes. N[...]

  • Page 10

    10 SERVICE INDICA TION SER VICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner . Blower ON A. Check fuse or circuit breaker . Operating Light OFF B. Ensure power pack is properly installed and latched. 2. Collecting cell shorted - T urn power [...]

  • Page 11

    11 TECHNICAL REP AIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact. NOTE: When servicing the power pack components, all wiring must be routed to factory specific[...]

  • Page 12

    12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack. Connect AC power to power pack using a[...]

  • Page 13

    13 NOTES[...]

  • Page 14

    14 REP AIR P AR TS[...]

  • Page 15

    15 ITEM NO. DESCRIPTION P ART NUMBER 16C28S-010 1 Cabinet N/A 2 Pre-Filter • F825-0337 3 Collecting Cell • F81 1-0321 4 Junction Box Cover F838-0072 5 * Screw #6 x 3/8 ------ 6 Connector , Female F818-0053 7 Power Pack Assembly F858-0921 8 Cell Handle F832-0039 9 Ionizing Wire F843-0500 10 Light F844-0131 1 1 Switch F876-0202 12 Power Pack, Cab[...]

  • Page 16

    White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63 123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE T O CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner o[...]