Emerson Process Management MSP-ULOG1 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson Process Management MSP-ULOG1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson Process Management MSP-ULOG1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson Process Management MSP-ULOG1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson Process Management MSP-ULOG1 should contain:
- informations concerning technical data of Emerson Process Management MSP-ULOG1
- name of the manufacturer and a year of construction of the Emerson Process Management MSP-ULOG1 item
- rules of operation, control and maintenance of the Emerson Process Management MSP-ULOG1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson Process Management MSP-ULOG1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson Process Management MSP-ULOG1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson Process Management service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson Process Management MSP-ULOG1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson Process Management MSP-ULOG1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Quick-start: For MSP-ULOG1/MSP-ULOG2 MSP-ULOG1/MSP-ULOG2 Quick-start Manual IP2042/QS, Rev. AA January 2006 www.mobrey.com[...]

  • Page 2

    (IP2042/QS) January 2006 2 Introduction What is this Quick-start? This Quick-Start is for anyone who has to install and comm ission the MSP-ULOG1 or MSP-ULOG2 ultrasonic system, and does not need in-depth information. For full installation instructions , you must refer to the installation (IM) manuals suppl ie d with the equipment. What are these M[...]

  • Page 3

    January 2006 (IP2042/QS) 3 Installation Location of MSP900SH • Install the transmitter above the liquid surfac e using the bracket provided. Important instru ctions for an open channel flow installation are given in IP2040/IM. • Do not mount the MSP900SH on a struct ure that is subject to vibration, or in a position where impact or thermal stre[...]

  • Page 4

    (IP2042/QS) January 2006 4 Getting started After completing the installation of both MCULOG control unit and the MSP 900SH transmitter, the next stage is to switch on. 1. Familiarise yourself with the front panel f ascia. Front Panel Fascia of MCULOGW Key to figure: c 4-line LCD with backlight. d Keypad with 6 function keys. e Status LED – flashe[...]

  • Page 5

    January 2006 (IP2042/QS) 5 How to display the menu system 4. Press the yellow ( ENTER ) key to display the top-level of the menu system. The primary displa y re- appears automatica ll y if there is no keypad activity for several minutes, if on-l ine. In addition, it re-appears when pressing the ESC key whilst at the top level of the menu system. 7.[...]

  • Page 6

    (IP2042/QS) January 2006 6 Application/Duty: Flow Measurement 1. With power on and the MSP900S H transmitter giving a 4-20mA signal to the MCUL OG unit (see previous pages), you can now programme the MCULOG for an application. This application example is for flow measurements. Requirement Live flow measurements in units of cubic metres per second. [...]

  • Page 7

    January 2006 (IP2042/QS) 7 Application Example: Flow Measurements using Duty Wizard[...]

  • Page 8

    (IP2042/QS) January 2006 8 Application/Duty: Logging Overview The MCULOG will log up to 4,800 events, where an event is the value of the Primary Variable (PV) at regul ar intervals; the logging interval is user-defi ne d ( P590 ). An interval va lue of 15 minutes will log the PV at 15-minute intervals, which equates to 50 days elapsed time. If the [...]

  • Page 9

    January 2006 (IP2042/QS) 9 Navigating to the LOG GING Menu Menu Map for LOGGING screens[...]

  • Page 10

    (IP2042/QS) January 2006 10 Other Features Restoring factory defaults (Erases all user-entered data) To re-set the MCULOG unit back to the factory defaults , navigate to the “Load Defaults” screen a nd press the ENTER key twice . Navigating to the LOA D DEFAULTS Screen PIN Security Personal Identification Number (PIN) securit y prevents un auth[...]

  • Page 11

    January 2006 (IP2042/QS) 11 Relays Relay outputs 1 to 4 are normally On Point/Off Poin t relays which may be used to start/stop pumps. They normally energise at one level and de-energise at a different level. Alternatively, they may be pr ogrammed as out -of-limits ala rms such that the y are energised bet ween define d po ints and will de- energis[...]

  • Page 12

    MSP-ULOG1/MSP-ULOG2 Quick-start Manual IP2042/QS, Rev. AA January 2006 The Emerson logo is a trade mark and se rvice mark of Emerson Elec tric Co. Rosemount is a registered trademark of Rosemount Inc. Mobrey is a registered trademark of Mobrey Ltd. A ll other marks are the property of their respective owners. We reserve the right to modify or impro[...]