Electro-Voice ZLX-15 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Electro-Voice ZLX-15, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Electro-Voice ZLX-15 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Electro-Voice ZLX-15. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Electro-Voice ZLX-15 should contain:
- informations concerning technical data of Electro-Voice ZLX-15
- name of the manufacturer and a year of construction of the Electro-Voice ZLX-15 item
- rules of operation, control and maintenance of the Electro-Voice ZLX-15 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Electro-Voice ZLX-15 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Electro-Voice ZLX-15, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Electro-Voice service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Electro-Voice ZLX-15.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Electro-Voice ZLX-15 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Z LX Series L oudspeak er Owner’ s Manual Z LX -1 2P Z LX -1 5P Z LX - 12 Z LX - 15[...]

  • Page 2

    Electro-V oice Z LX Series Owner’ s Manual Impor t ant Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturers instru[...]

  • Page 3

    Electro-V oice Z LX Series Owner’ s Manual T able of Contents Important S afety Instructions .................................................................................................................................................................................. 2 FCC Information ..........................................................[...]

  • Page 4

    Electro-V oice Z LX Series Owner’ s Manual Description Quick Setup Thank you for c hoosing an Electro-V oice Z LX series powered and passive loudspeaker systems. Please take time to consult this manual to understand all the features built into your Electro-V oice system and fully utilize its performance capabilities. Z LX models cut through the c[...]

  • Page 5

    Electro-V oice Z LX Series Owner’ s Manual System Features Z LX -1 2P & Z LX -1 5P —Powered Loudspeaker Systems The only loudspeaker in its class that matc hes EV-engineered drivers with a custom-built Class-D amplifier module and powerful DS P . W hether pole-mounted or used as a floor monitor , Z LX delivers stunning sonic impact and in[...]

  • Page 6

    Electro-V oice Z LX Series Owner’ s Manual T ripod and Floor Monitor Operation Floor Monitor Electro-V oice Z LX series loudspeakers may be used as a floor monitor by placing the speaker on the integral monitor angle. Make sure to: • Place the speaker on a level, stable surface that is solid and secure. • Route cables so that performer[...]

  • Page 7

    Electro-V oice Z LX Series Owner’ s Manual 7 T ripod and Floor Monitor Operation (cont.) Figure 2a: Z LX on T ripod Stand Figure 2b: Z LX Full-R ange/Sub Stack with Pole Mount T ripod Electro-V oice Z LX series loudspeakers include 35 mm (1-3/8 in) stand mounts to allow mounting on tripod stands or above an E LX118P . Make sure to: • Check t[...]

  • Page 8

    Electro-V oice Z LX Series Owner’ s Manual Amplifier Controls Figure 3: Z LX -1 2P & Z LX-15P Amplifier Panel The ZLX amplifier has a combination of controls and connectors to ensure the most versatile loudspeaker system. Each component below has a description. 8 1. LCD-DS P Control & Monitoring Interface 2. MASTE R VOL — T urn the d[...]

  • Page 9

    Electro-V oice Z LX Series Owner’ s Manual L C D D S P Controls Z LX -1 2P & Z LX -1 5P LCD DS P Controls Menu EXIT DSP MODE M U S IC (Default) LIVE SPEECH CLU B L OC A TION PO LE (Default) MONIT OR B RACK ET T REBL E 0 dB (Default) -1 0 dB to +1 0 dB BAS S 0 dB (Default) -1 0 dB to +1 0 dB SUB OF F (Default) 80Hz 1 00Hz 120Hz E LX118P System[...]

  • Page 10

    Electro-V oice Z LX Series Owner’ s Manual Exit The Exit menu is used to return to the home screen. Mode The Mode menu is used to configure the type of sound the louspeaker will deliver . The selection c hoices are M U S I C, LIVE, SP E E CH, or C LU B. The default selection is M US I C. • MUSIC —Used for recorded music playback. • L[...]

  • Page 11

    Electro-V oice Z LX Series Owner’ s Manual 11 Recommended Configurations Daisy-Chaining Full-Range Systems (P owered versions shown) M P3 Player V ocal Microphone Note : The direction of the arrow indicates the signal path.[...]

  • Page 12

    Electro-V oice Z LX Series Owner’ s Manual Recommended Configurations (cont.) Using Full-Range Systems as Monitors (P owered versions shown) V ocal Microphone Instrument 12 Note : The direction of the arrow indicates the signal path.[...]

  • Page 13

    Electro-V oice Z LX Series Owner’ s Manual 13 Recommended Configurations (cont.) Stacking F ull-Range Systems w/ Subwoofers (Stereo Z LX -1 2P with two E LX1 1 8P’s shown) Mixer N OT E : Z LX -15P loudspeakers may also be used in combination with E LX118P subwoofers. Note : The direction of the arrow indicates the signal path.[...]

  • Page 14

    Electro-V oice Z LX Series Owner’ s Manual 14 Specifications—Z LX Powered 1 Using M US IC DS P preset. Model (Part Number) Z LX -1 2P (Z LX -1 2P) Z LX -1 5P ( Z LX -1 5P) Fr eq. Response 1 : 65 Hz – 18 kHz 55 Hz – 18 kHz Fr eq. Range 1 : 50 Hz – 20 kHz 42 Hz – 20 kHz Max. Measured SP L: 1 26 dB 1 27 dB Coverage (Horiz. x V ert.): 90°[...]

  • Page 15

    Electro-V oice Z LX Series Owner’ s Manual Specifications—Z LX Passive Model (Part Number) Z LX - 12 (Z LX -1 2) Z LX - 15 (Z LX -1 5) Fr eq. Response 2 : 82 Hz – 18 kHz 5 6 Hz – 18 kHz Fr eq. Range: 55 Hz – 20 kHz 4 4 Hz – 20 kHz Axial Sensitivity: 95 dB 96 dB Max. Measured SP L: 1 25 dB 1 26 dB Recommended H P Fr eq.: 40 Hz Coverage [...]

  • Page 16

    Electro-V oice Z LX Series Owner’ s Manual 16 Dimensions—Z LX Powered Rear View Left V iew Bottom View Front V iew Z LX -1 2P Z LX -1 5P 383 mm [15 in] 187 mm [7 in] 423 mm [17 in] 43.4° 43.4° [27 in] 685 mm 610 mm [24 in] 356 mm [14 in] 183 mm [7 in] 356 mm [14 in] 43.4° 43.4° Fr ont View Left V iew Bottom View Rear View[...]

  • Page 17

    Electro-V oice Z LX Series Owner’ s Manual Dimensions—Z LX Passive Fr ont View Left V iew Bottom View Rear View Z LX - 12 Z LX - 15 610 mm [24 in] 356 mm [14 in] 183 mm [7 in] 356 mm [14 in] 43.4° 43.4° 383 mm [15 in] 187 mm [7 in] 423 mm [17 in] 43.4° 43.4° [27 in] 685 mm Fr ont View Left V iew Bottom View Rear V iew 17[...]

  • Page 18

    Electro-V oice Z LX Series Owner’ s Manual F requency Response Graphs—Z LX Powered 50 100 1000 10000 20000 70 80 90 100 11 0 Sensitivit y (dB) Frequenc y (Hz) Frequency R esponse, Full Space, Live Mode Frequency R esponse, Full Space, Music Mode Frequency R esponse, Full Space, Speech Mode Frequency R esponse, Full Space, Club Mode Z LX -1 2P 5[...]

  • Page 19

    Electro-V oice Z LX Series Owner’ s Manual 19 F requency Response Graphs—Z LX Passive 50 100 1000 10000 20000 3.16 10 100 70 80 90 100 11 0 Impedance (Ohms) Sensitivit y (dB) Frequenc y (Hz) Frequency R esponse, Full Space Im pedanc e Z LX - 12 50 100 1000 10000 20000 3.16 10 100 70 80 90 100 11 0 Impedance (Ohms) Sensitivit y (dB) Frequenc y ([...]

  • Page 20

    Electro-V oice Z LX Series Owner’ s Manual Z LX Series Model Reference T able Commercial Code Description Finish Z LX -12P-U S 12” T wo-W ay Powered Loudspeaker Black Z LX -12P-E U 12” T wo-W ay Powered Loudspeaker Black Z LX -15P-U S 15” T wo-W ay Powered Loudspeaker Black Z LX -15P-E U 15” T wo-W ay Powered Loudspeaker Black Z LX -12 12[...]

  • Page 21

    Electro-V oice Z LX Series Owner’ s Manual 21 T roubleshooting Problem Possible Cause(s) Action 1. No Sound Amplifier Connect a known working test speaker to the amplifier outputs. If there is no sound, chec k that all the electronics are on, the signal routing is correct, the source is active, the volume is turned up, and so on. Correct/repair[...]

  • Page 22

    12000 Portland A venue South, Burnsville, M N 55337 Phone: 952/88 4-4051, Fax: 952/8 8 4-0043 www .electrov oice.com © Bosch Communications Systems 11/20 12 Part Number F0 1U27 51 81 Rev 01 U.S.A. and Canada only . For customer orders, contact Customer Service at: 800/3 92-34 97 Fax: 800/955-6831 Europe, Africa, and Middle East only . For customer[...]