Edge-Core RPS600WA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Edge-Core RPS600WA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Edge-Core RPS600WA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Edge-Core RPS600WA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Edge-Core RPS600WA should contain:
- informations concerning technical data of Edge-Core RPS600WA
- name of the manufacturer and a year of construction of the Edge-Core RPS600WA item
- rules of operation, control and maintenance of the Edge-Core RPS600WA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Edge-Core RPS600WA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Edge-Core RPS600WA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Edge-Core service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Edge-Core RPS600WA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Edge-Core RPS600WA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    t h e r e i s n o e d g e l i m i t t h e r e i s n o p e r m a n e n t c o r e t h e r e i s n o e d g e l i m i t t h e r e i s n o p e r m a n e n t c o r e External Redundant Power Supply Installation Gui de[...]

  • Page 2

    [...]

  • Page 3

    Installation G uide Exter nal Redund ant Pow er Su pply with 4 Ind epende nt Redun dant Po wer Supply Port s[...]

  • Page 4

    RPS600 WA-38 E01200 5-R01 1500000 46600 A[...]

  • Page 5

    iii Compliance s FCC - Class B This equipment generates, uses, and can r adiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been teste d and found to comply with the limits for a Class B computing device pursuant to Subpart B of Pa rt 15 of F[...]

  • Page 6

    iv CE Mark Declaration of Conformance for EMI and Safe ty (EEC) This information technology equipment compli es with the require ments of the Council Directive 89/336/EE C on the App roximation of t he laws of the Mem ber St ates relating to Electromagnetic Compatibility and 73 /23/EEC fo r electrical equipment used within certain voltage limits an[...]

  • Page 7

    v This unit cannot be powe red from IT † supplies. If your supplies are of IT type, this unit must be pow ered by 230 V (2P+T) via an isolation transform er ratio 1:1, wit h the secondary connect ion point labelled Neutral, connected direc tly to earth ( ground). † Impédance à la terre Power Co rd Set U.S.A. an d Cana da The cord set mu st be[...]

  • Page 8

    vi Veuillez lire à fond l'information de la sécurité suiv ante avant d'installer le RPS: A VERTI SSEM ENT : L ’installation et la dépose de c e groupe doivent ê tre confiés à un personnel qualifié. • Ne branchez pas v otre apparei l sur une prise sect eur (aliment ation électrique) lorsqu'il n'y a pas de connexion d[...]

  • Page 9

    vii Bitte unbedingt vor dem Einbauen des RPS die folge nden Sicherheitsanweisungen d urchlesen: W ARNUN G: Die Installation und der A usbau des Geräts darf nur dur ch Fachpersonal erfolgen. • Diese Anleitung ist fr die Benutzung durc h Netzwerkadministratoren vorgeseh en, die fr die Installation und das einstellen von Net z werkkomponent en vera[...]

  • Page 10

    viii Environ mental S tatement The manufacturer of this product endeavours to sus tain an environmentally-friendly policy throughout the entire production process. Th is is achieved though the following means: • Adherenc e to na tional legi slation an d regula tions on env ironm ental prod uction standar ds. • Co nser vati on o f op erat iona l[...]

  • Page 11

    ix Contents Chapter 1: About the Redundant Po wer Supply 1-1 Overview 1-1 Feat ures and Be nefits 1-1 Front and Rear Panels 1-2 LEDs 1-2 Suppo rt ed Sw itc hes 1-4 Chapter 2: Inst alling the Redu ndant Power Su pply 2-1 Install ation 2 -1 Selecti ng a Site 2-1 Equipm ent Checkl ist 2-2 Package Co ntents 2-2 Optional Rack-Mou nting Equipment 2-2 Mou[...]

  • Page 12

    x Tables Table 1- 1 Port Sta tus LEDs 1-3 Table 1- 2 System LEDs 1-3 Table 1-3 Suppo rt ed Sw itc h 1-4 Table A-1 . Troub leshooti ng Chart A-1[...]

  • Page 13

    xi Figures Figure 1 -1 Front and Rear Pa nels 1-2 Figur e 1-2 LEDs 1-2 Figure 2 -1. Attaching the Bracke ts 2-3 Figure 2 -2. Installin g the RPS in a Rack 2-3 Figure 2 -3. Attaching the Adhe sive Fee t 2-4 Figure 2 -4. Power Rece ptacle 2-5 Figure 2 -5. RPS Support ing Four Swit ches 2-6[...]

  • Page 14

    xii Figures[...]

  • Page 15

    1-1 Chapter 1 : About th e Redun dant Power S upply Overview This Ex ternal R edundan t Power Supply (RP S) can su pply 600 Watts of backup power to fou r switch es in t he event of an AC loss or failure of an internal pow er supply . Features and Benefits • Supp orts four sw itch units with 11.5 V DC o utputs of up to 150 W. • Indicat or LEDs [...]

  • Page 16

    About the Redundant Po wer Suppl y 1-2 1 Front and Rear Panels Four power indica tors and one f an indicat or are loca ted on the RPS’s front panel. While the AC supply a nd DC ba ckup rece ptacles are l ocated on the RPS’s rear panel. Figu re 1 -1 Fro nt a nd Re ar P ane ls LEDs The fol lowi ng di agr am an d t abl es de scri be t he f unct io[...]

  • Page 17

    LEDs 1-3 1 Table 1- 1 Po rt Statu s LEDs LED (1-4 ) Conditio n Status Link Off The port does n ot hav e a val id conn ection to a sw itch. On Y ellow The port has a valid co nnecti on to a switch . Flashi ng Y e llow There ha s been an RP S internal power failure . Activity Off The p ort is n ot prov iding pow er to th e conn ected switch. Flashi n[...]

  • Page 18

    About the Redundant Po wer Suppl y 1-4 1 Supported Switches Table 1 -3 Supp orte d Swit ch Switches with 1 4-pin R PU co nnect or on r ear pa nel. ES3526V ES3526V 1 ES3526VA ES3526Y ES3526YA ES3550C ES3550C 1 ES3550YA ES3628C ES3652C ES4512B ES4524B ES4524C ES4548C ES4525 ES4549 ES4612 ES4624C ES4625 ES4649[...]

  • Page 19

    2-1 Chapter 2 : Installing the Redund ant Po wer Supply Installation The RPS may be placed on a deskt op or mount ed in a rac k. Cauti on: DO NOT place the RPS on the floor as t he case is not waterproof. It is recommended that this RPS be installed in a network equipment rack. Cauti on: Use only the RPS cables supplied with t h e unit. Using any o[...]

  • Page 20

    Installing th e Redundant Power Su pply 2-2 2 Equipment Checklist After unpacking th e RPS, ch eck the con tents to be sur e you have re ceived a ll the compon ents. Then, be fore begi nning the installation , be sure y ou have all other necessa ry ins tallation equipm ent. Package Contents • Redu ndant Powe r Supply Unit • One AC Su pply Power[...]

  • Page 21

    Mounting 2-3 2 T o r ack-m ount d evice s: 1. Attach the brack ets to the devi ce using the s crews provided in the Brack et Moun ting Kit . Figure 2-1. A ttaching th e Bracke ts 2. Mount the device i n the rack , using four rack-mou nting sc rews ( not prov ided). Fig ure 2 -2 . In st al ling t he RP S in a R ac k Mont age (Rac k Mounti ng Inst ru[...]

  • Page 22

    Installing th e Redundant Power Su pply 2-4 2 liegt. (Siehe "Temperatur" auf Seite C-1.) • Mechanisc he Last: Stellen Sie kein Gerät auf eine Rack-Mont ageeinheit. • Strom überlastung: Stellen Sie s icher, dass der Netzkreis der Rac keinheit nicht überlastet wird. • Erdung: Die Rack-Montageeinheit muss richtig geerdet werde n. Be[...]

  • Page 23

    Connecting Sw itches to the RPS 2-5 2 Connecting Switches to th e RPS Cauti on: DO NOT connect the RPS to an AC power source until DC power cords have been connected to the support ed switches. Ot herwise, th e RPS may unnec essarily begin supplying backup power if the switch is not yet powered up. T o conn ect switch es to the RP S: 1. Connec t on[...]

  • Page 24

    Installing th e Redundant Power Su pply 2-6 2 Figure 2-5. RPS Supporting Four Switches Note: For International use, you may need to change t he AC line cord. You must use a line cord set that has been approv ed for the receptacle type in y our country. RPS output port Stack RPS input port AC Power Supply No.1 AC Power Supply No.2 RPS Unit 100-240V,[...]

  • Page 25

    A-1 Appendix A: Tr oubleshoo ting Diagnosing RPS Indicato rs Table A- 1. Troub lesho oting Chart Symptom Action Power LE D is O ff • Intern al powe r supp ly is dis conne cted. • Check conne ctions betwee n the RPS, th e pow er cord, an d the wall outlet. • Conta ct Tech nical S upport . Link LED is Of f • The por t do es not have a val id [...]

  • Page 26

    T roubleshooti ng A-2 A Power and Cooling Probl ems If the PWR LED does not turn on when the power c ord is plugg ed in, you ma y have a problem with the p ower outl et, powe r cord, or inte rnal pow er supp ly . How ever , if the unit po wers off after runni ng for a whil e, check f or loose power co nnecti ons, power los ses or sur ges at the pow[...]

  • Page 27

    B-1 Appendix B: Spe cifica tions Physical Characteristi cs Ports 4 RPS DC pow er outlets (IEC socket 21 6C743- 07) LEDs Port: Link, Activity System: Power , Fan, Thermal We ig h t 5.5 kg (12.1 lbs) Size 44.0 x 3 2.3 x 4.3 c m (17.3 4 x 12.6 x 1.69 in.) T emp erat ure Oper ati ng: 0 to 45 ° C (32 to 1 10 ° F) S torage: -40 t o 70 ° C (-40 to 1 58[...]

  • Page 28

    Specifications B-2 B Overcu rrent Pr otection Ports are shutdow n when out put exce eds 14. 5 A Over-voltage Protection Ports are shutdow n when out put exce eds 12. 3 V Power Supply +1 1.5 VDC Initial a ccuracy: +/- 1% Current: 2 A (minimum), 10 A (maximum) Line regul ation: +/- 1% Load regu lation: +/- 10% Overshoo t and un dershoo t: 5% Complian[...]

  • Page 29

    Index-1 A adhesiv e feet, at taching 2- 4 air flow requ ireme nts 2-1 B brackets, a ttaching 2- 3 C compl iances EMC B-2 safe ty B-2 contents o f pack age 2-2 cooling pr oblems A-2 cord se ts, in tern at iona l 2-6 D desktop moun ting 2-4 E equipmen t chec klist 2-2 F front pane l of RPS 1 -2 G grounding fo r rack s 2-2 I installation desktop or sh[...]

  • Page 30

    Index Index-2[...]

  • Page 31

    [...]

  • Page 32

    RPS600W A-38 E012 005-R 01 150000 046600 A[...]