DMP Electronics LT-0229 (5 97) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of DMP Electronics LT-0229 (5 97), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DMP Electronics LT-0229 (5 97) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of DMP Electronics LT-0229 (5 97). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of DMP Electronics LT-0229 (5 97) should contain:
- informations concerning technical data of DMP Electronics LT-0229 (5 97)
- name of the manufacturer and a year of construction of the DMP Electronics LT-0229 (5 97) item
- rules of operation, control and maintenance of the DMP Electronics LT-0229 (5 97) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DMP Electronics LT-0229 (5 97) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DMP Electronics LT-0229 (5 97), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DMP Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DMP Electronics LT-0229 (5 97).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the DMP Electronics LT-0229 (5 97) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    LT-0229 (5/97) XR10/XR20 Command Processor Panels Installation Guide 10/26 Zone Burglary/Fire/Access Control Panels with Built-in Communicator 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 : http://www. guardianalarms . net[...]

  • Page 2

    MODEL XR10/XR20 COMMAND PROCESSOR INST ALLA TION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference with radio and television reception. It has been type tested and found to comply with the limits for[...]

  • Page 3

    TABLE OF CONTENTS Panel Specifications Power supply ........................................................................................ 1.1 Communication .................................................................................... 1.2 Panel zones ......................................................................................... [...]

  • Page 4

    TABLE OF CONTENTS Section Reset Jumpers J16 Description ......................................................................................... 14.1 Universal UL Burglary Specifications Introduction ........................................................................................ 15.1 Wiring ................................................[...]

  • Page 5

    Page 1 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Panel Specifications 1.1 Power supply Transformer Input: 16.5 VAC 40VA (Models 320 wire-in or 321 plug-in) Standby Battery: 12 VDC 6.5Ah (40VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Output: 12 VDC [...]

  • Page 6

    Page 2 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 2.3 Before you begin Before installing the XR10/XR20, we recommend you read through the entire contents of this guide. Familiarize yourself with the features of the panel and the key points to remember during the installation. Be sure t[...]

  • Page 7

    Page 3 Introduction 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide System Components 3.1 Description The DMP XR10/XR20 system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 6.5 Ah battery. You can add up to four Security Command keypads to th[...]

  • Page 8

    Page 4 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Installation 4.1 Mounting the enclosure The metal enclosure for the XR10/XR20 must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the XR10/XR20 PC board[...]

  • Page 9

    Page 5 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base with keypad circuit board to a wall or other flat surface using the screw holes provided on each corner. Before mounting the bas[...]

  • Page 10

    Page 6 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 6.4 Discharge/recharge The XR10/XR20 battery charging circuit float charges at 13.9 VDC at a maximum current of 1.2 Amps using a 40VA transformer. The total current available is reduced by the combined auxiliary current draw from termin[...]

  • Page 11

    Page 7 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum output of 1.5 Amps. This output can be steady or pulsed depending upon the Bell Act[...]

  • Page 12

    Page 8 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 10.2 Operational parameters Each burglary protection zone detects three conditions: open, normal, and short. The parameters for each are listed below: Condition Resistance on zone Voltage on right terminal Open over 1300 ohms over 2.0 V[...]

  • Page 13

    Page 9 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not provide a voltage but instead switc[...]

  • Page 14

    Page 10 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 13.4 Ground start To configure the XR10/XR20 for ground start operation, you must install the appropriate ground start module and program one of the panel's available annunciator outputs for Ground Start operation. Refer to the XR[...]

  • Page 15

    Page 11 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UNIVERSAL UL BURGLARY SPECIFICATIONS 15.1 Introduction The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards.[...]

  • Page 16

    Page 12 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide UL 1610 and 1076 SPECIFICATIONS Central-Station and Proprietary Burglar-Alarm Units 17.1 Opening/Closing reports The Opening/Closing Reports option must be programmed as YES. See section 5.2 of the XR10 Programming Guide (LT-0230) and [...]

  • Page 17

    Page 13 Installation 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10/XR20 Installation Guide 19.6 Mercantile Safe and Vault When the DMP Model 349A housing is used, the XR10/XR20 provides operation as a mercantile safe and vault alarm. Bell Supervision and wiring must be in accordance with UL 681. If the Model XR10/XR20 is mou[...]

  • Page 18

    Page 14 Troubleshooting 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Installation Guide Problem Possible Cause Solution Security Command keypads display " SERVICE REQUIRED" J16 reset jumper is installed. Open or short on the green data wire to the keypad. Bad keypad or zone expander. Remove the J16 reset jumper. C[...]