Dimplex SI 9ME manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dimplex SI 9ME, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimplex SI 9ME one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dimplex SI 9ME. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dimplex SI 9ME should contain:
- informations concerning technical data of Dimplex SI 9ME
- name of the manufacturer and a year of construction of the Dimplex SI 9ME item
- rules of operation, control and maintenance of the Dimplex SI 9ME item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimplex SI 9ME alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimplex SI 9ME, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimplex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimplex SI 9ME.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimplex SI 9ME item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Sole/W asser- Wärmepumpe für Innenaufstellung SI 5ME SI 7ME SI 9ME SI 11ME SI 14ME Brine-to-W at er Heat P ump for Indoor Installation P ompe à chaleur eau gly colée-eau pour installation intérieur e Montage- und Gebrauchsanw eisung Deutsch English Français Instruc tions d’installation et d’utilisation Installation and Opera ting Instruc [...]

  • Page 2

    www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ ............................................................... ...... E-2 1.1 Important Information ....... .................... ................ ................... ................ .................... ..... ................. ...... E-[...]

  • Page 3

    E-2 English 1 1 Please Read Immediately 1.1 Important Information ATTENTION! The heat pump is not secu red to the wooden pallet. ATTENTION! The heat pump must not be tilted more than 45° (in any direction) . ATTENTION! Do not use the holes in the panel assemblies for lifting the device! ATTENTION! Flush the heating system prio r to connecting the [...]

  • Page 4

    www.dimplex.de E-3 English 3 2 Purpose of the Heat Pump 2.1 Application The brine-to-water heat pump is designed for use in existi ng or newly built heati ng systems. Brine is used as the hea t carrier in the heat source syst em. Borehole heat exchangers, ground heat collectors or similar systems can be used as the heat source. 2.2 Operating Princi[...]

  • Page 5

    E-4 English 4 4 Accessories 4.1 Brine Circuit Manifold The brine circuit mani fold merges the individua l collector loops of the heat source system into a single main pipe which is con- nected to the heat pump . Integra ted ball val ves a ll ow the i ndi vid - ual brine circuits to be shut of f for de-aeration purposes. 5 Transport A lift truck is [...]

  • Page 6

    www.dimplex.de E-5 English 7.4 7 Installation 7.1 General Information The following con nections need to be established on the heat pump:  Flow and return f low of the bri ne system  Flow and return f low of the heat ing system  Power supp ly 7.2 Heating System Connection ATTENTION! Flush the heating system prio r to connecting the heat pu[...]

  • Page 7

    E-6 English 8 8 Commissioning 8.1 General Information To ensure that start-up is performed correctly, it should only be carried out by an after-sales servic e technici an authorise d by the manufacturer. This ma y be a condi tion f or exten din g the guaran - tee (see Warranty ). 8.2 Preparation The following items need to be checked prior to start[...]

  • Page 8

    www.dimplex.de E-7 English 11 9 Maintenance and Cleaning 9.1 Maintenance The heat pump is maintenan ce-free. To prevent faults due to sediment in the heat exchangers, care must be t aken to ensure that no impurities ca n enter either the heat source sys tem or the heating system. I n the event that operatin g malfunctions due to contamination occur[...]

  • Page 9

    E-8 English 12 12 Device Information 1 Type and order code SI 5ME SI 7ME SI 9ME SI 11ME SI 14ME 2D e s i g n 2.1 Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 IP 20 2.2 In stallatio n Locatio n Indoors Indoors Indoors In doors Indoors 3 Performanc e data 3.1 Operating temperature li mits: Heating water flow °C Up to 58 Up to [...]

  • Page 10

    www.dimplex.de A-I Anhang · Ap pendix · Annexes Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas cotés .............................................................. ..... A-II 1.1 Maßbild / Dimension Drawing / Sc héma coté ............... ................. ................... ................ .................. .... A[...]

  • Page 11

    A-II Anhang · Ap pendix · Annexes 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté :lUPHTXHOOH (LQJDQJLQ:3 ´ $XHQJHZLQGH +HDWVRXUFH +HDWSXPSLQOHW ´H[WHUQDOWKUHDG 6RXUFHGHFKDOHXU (QWUpHGDQVOD3 $& )LO[...]

  • Page 12

    www.dimplex.de A-III Anhang · Ap pendix · Annexes 2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic Curv es / Courbes caractéristiques SI 5ME                                         ?[...]

  • Page 13

    A-IV Anhang · Ap pendix · Annexes 2.2 2.2 Kennlinien / Characteristic Curv es / Courbes caractéristiques SI 7ME                                                ?[...]

  • Page 14

    www.dimplex.de A-V Anhang · Ap pendix · Annexes 2.3 2.3 Kennlinien / Characteristic Curv es / Courbes caractéristiques SI 9ME                                            ?[...]

  • Page 15

    A-VI Anhang · Ap pendix · Annexes 2.4 2.4 Kennlinien / Characteristic Curv es / Courbes caractéristiques SI 11ME                                               ?[...]

  • Page 16

    www.dimplex.de A-VII Anhang · Ap pendix · Annexes 2.5 2.5 Kennlinien / Characteristic Curv es / Courbes caractéristiques SI 14ME +HL]OHLVWXQJLQ>N:@ +HDWLQJFDSDFLWLQ>N:@ 3XLVVDQFHGHFKDXIIDJHHQ>N:@ :DVVHUDXVWULWWVWHPSHUDWXULQ>&@ :DWHURXWOHWWHPSHUDWXUHLQ>&@ 7 HPSpUDWXUHGH[...]

  • Page 17

    A-VIII Anhang · Ap pendix · Annexes 3 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande[...]

  • Page 18

    www.dimplex.de A-IX Anhang · Ap pendix · Annexes 3.2 3.2 Last / Load / Charge[...]

  • Page 19

    A-X Anhang · Ap pendix · Annexes 3.3 3.3 Klemmenanschlussplan / Terminal Connection Plan / Schéma de connexion des bornes 1HW]0DLQV5pVHDX 1HW]/DVW0DLQV/RDG 5pVHDX&KDUJH RGHUÂRUÂRX[...]

  • Page 20

    www.dimplex.de A-XI Anhang · Ap pendix · Annexes 3.4 3.4 Legende / Legend / Légende A1 Drahtbrücke, muss eingelegt werden, wenn kein Sperrschütz vorhande n ist Wire jumper, must be inserted if no blocking c on- tactor is fitted Le cavalier à fil doit être inséré en absence de dis- joncteur de blocage du fournisseur d'énergie. A2 Drah[...]

  • Page 21

    A-XII Anhang · Ap pendix · Annexes 4 4 Hydraulisches Prinzips chema / Hydraulic Plumbing Diagram / Schéma hydraulique 4.1 Darstellung / Schemati c View / Représentation[...]

  • Page 22

    www.dimplex.de A-XIII Anhang · Ap pendix · Annexes 4.2 4.2 Legende / Legend / Légende Absperrventil Shut off valve Robinet d’arrêt Absperrventil mit Entleerung Shutoff valve with drainage Robinet d’arrêt avec purge Überstromventil Overflow valve Vanne de trop-plein Sicherheitsventi l Safety valve Vanne de sécurité Umwälzpumpe Circulati[...]

  • Page 23

    A-XIV Anhang · Ap pendix · Annexes 5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité[...]

  • Page 24

    Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors. Sous réserve d’erreurs et modifications. +49 (0) 9221 709 565 www.dimplex.de[...]