Dimplex SI 75ZS manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dimplex SI 75ZS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimplex SI 75ZS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dimplex SI 75ZS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dimplex SI 75ZS should contain:
- informations concerning technical data of Dimplex SI 75ZS
- name of the manufacturer and a year of construction of the Dimplex SI 75ZS item
- rules of operation, control and maintenance of the Dimplex SI 75ZS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimplex SI 75ZS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimplex SI 75ZS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimplex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimplex SI 75ZS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimplex SI 75ZS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INST ALLA TION and OPERA TING INSTRUCTIONS Brine-to-W ater Heat Pump for Indoor Installation CE Order No.: 452234.67.01 FD 851 1 SI 50ZS / SI 75ZS / SI 100ZS[...]

  • Page 2

    2 CONTENTS 1 READ IMMEDIA TEL Y 3 1. 1 Important Information 1. 2 Legal Provisions and Guidelines 1. 3 Energy-Efficient Use of the Heat Pump 2 PURPOSE OF HEA T PUMP 4 2.1 Application 2. 2 Principle of Operation 3 SCOPE OF DELIVER Y 4 3. 1 Baseline Unit 4 ACCESSORIES 5 4. 1 Connecting Flanges 5 TRANSPORT 5 6 INST ALLA TION 6 6.1 General Information [...]

  • Page 3

    3 READ IMMEDIA TEL Y 1.1 Important Information Any work on the heat pump may only be performed by an authorised and qualified customer service. The transport securing devices must be removed after the transport. The heat pump must not be tilted more than max. 45 ° (in either direction). Flush the heating system prior to connecting the heat pump. T[...]

  • Page 4

    4 3 PURPOSE OF HEA T PUMP SCOPE OF DELIVER Y PURPOSE OF THE HEA T PUMP 2.1 Application The brine-to-water heat pump is designed for use in existing or newly built heating systems. Brine is used as the heat carrier in the heat source system. Ground coils, ground collectors or similar systems can be used as the heat source. 2.2 Principle of Operation[...]

  • Page 5

    5 TRANSPORT 5 ACCESSORIES TRANSPORT CAUTION! CAUTION! 4 ACCESSORIES 4.1 Connecting Flanges The use of flat-sealing connecting flanges allows the unit, as an option, to be connected by means of flanges. For the transport by means of a hand truck or boiler trolley , position the latter under the front end of the unit below the transport security devi[...]

  • Page 6

    6 67 INST ALLA TION MOUNTING INST ALLA TION 6.1 General Information As a rule, the unit must be installed indoors on a level, smooth and horizontal surface. The entire base frame should make full contact with the surface in order to ensure adequate sound insulation. Failing this, additional sound insulation measures may become necessary. The heat p[...]

  • Page 7

    7 MOUNTING 7.3 Connection on Heat Source Side The following procedure must be observed when making the connection: Connect the brine line to the flow and return pipe of the heat pump. The supplied strainer must be fitted in the heat source inlet of the heat pump in order to protect the evaporator against the ingress of impurities. In addition, a po[...]

  • Page 8

    8 COMMISSIONING 8 CAUTION! COMMISSIONING 8.1 General Information T o ensure proper commissioning it should be carried out by a customer service authorised by the manu- facturer . Only then can an extended warranty period of 3 years in total be granted (cf. Warranty service). 8.2 Preparatory Steps Prior to commissioning, the following items need to [...]

  • Page 9

    9 CARE/CLEANING 9.3 Cleaning of Heat Source Side The supplied strainer is to be install- ed in the heat source inlet of the heat pump in order to protect the evaporator against conta- mination. The filter screen of the strainer should be cleaned one day after commissioning, thereafter every week. If no more contamination can be noticed any more, th[...]

  • Page 10

    10 11 DECOMMISSIONING 1 1.1 Summer Shutdown A heating-only system can be shut down in summer (no domestic water heating). This can be ef fected by means of the mode selector switch of the heat pump controller . Please follow the instructions contained in the controller's in-stallation and operating manual. T o avoid possible frost damage, shut[...]

  • Page 11

    11 APPENDIX 12 APPENDIX 12.1 Dimensioned Drawings 12.1.1 Dimensioned Drawing SI 50ZS 12 12.1.2 Dimensioned Drawing SI 75ZS 13 12.1.3 Dimensioned Drawing SI 100ZS 14 12.2 Equipment Data 1 5 12.3 Diagrams 12.3.1 Characteristic Curves SI 50ZS 1 6 12.3.2 Characteristic Curves SI 75ZS 1 7 12.3.3 Characteristic Curves SI 100ZS 18 12.4 Wiring Diagrams 12.[...]

  • Page 12

    12 APPENDIX: 12.1 DIMENSIONED DRAWINGS 12.1.1 Dimensioned Drawing SI 50ZS ( 1 : 20 ) 1 8 9 1 256,5 928 1348 1290 682 1 0 0 1 1 3 0 , 5 11 2 177 1 7 7 0 749 690 1 1 4 2 1 2 5 5 1 5 9 8 1 7 0 3 20 ca. 1 5 0 0 108 315 2 1/2" internal / external thread Heat source Heat pump inlet 1 1/2" internal / external thread Heating water supply Heat pum[...]

  • Page 13

    13 APPENDIX: 12.1 DIMENSIONED DRAWINGS 12.1.2 Dimensioned Drawing SI 75ZS ( 1 : 20 ) 1 1 3 0 , 5 1 1 4 2 1 2 5 5 1 5 9 8 1 7 0 3 20 ca. 690 749 1 7 7 0 828 256,5 1348 1 8 9 1 1 0 0 177 11 2 682 1290 1 5 0 0 108 315 2 1/2" internal / external thread Heat source Heat pump inlet 2 1/2" internal / external thread Heat source Heat pump outlet [...]

  • Page 14

    14 APPENDIX: 12.1 DIMENSIONED DRAWINGS 12.2.3 Dimensioned Drawing SI 100ZS ( 1 : 20 ) 256,5 693 1348 315 108 1 5 0 0 1 1 3 0 , 5 11 2 177 682 1290 1 0 0 1 8 9 1 20 ca. 1 7 0 3 1 5 9 8 1 2 5 5 1 1 4 2 749 1 7 7 0 690 3" internal / external thread Heat source Heat pump inlet 3" internal / external thread Heat source Heat pump outlet 2"[...]

  • Page 15

    15 APPENDIX: 12.2 EQUIPMENT D A T A Equipment Data EQUIPMENT DATA for brine-to-water heat pumps for heating purposes 1 TYPE AND COMMERCIAL DESCRIPTION ..50ZSN ..75ZSN ..100ZSN 2 MODEL 2.1 Enclosure type acc. to EN 60 529 IP 21 IP 21 IP 21 2.2 Installation site indoors indoors indoors 3 PERFORMANCE DATA 3.1 Operating temperature limits: Heating wate[...]

  • Page 16

    16 0 10 20 30 40 50 60 70 80 - 1 0 - 5 0 5 1 01 52 02 53 0 35 50 35 50 0 1 2 3 4 5 6 7 8 9 -10 -5 0 5 10 15 20 25 30 35 50 0 2 4 6 8 10 12 14 16 - 1 0 - 5 0 5 1 01 52 02 53 0 50 35 50 35 0 2000 4000 6000 8000 10000 02468 1 0 0 5000 10000 15000 20000 25000 30000 35000 0 5 10 15 20 Brine inlet temperature in [°C] Heating capacity in [kW] Water outle[...]

  • Page 17

    17 0 20 40 60 80 100 120 -10 -5 0 5 10 15 20 25 30 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 5 10 15 20 25 -10 -5 0 5 10 15 20 25 30 Brine inlet temperature in [°C] Power consumption (incl. power input to pump) 50 35 50 35 0 1 2 3 4 5 6 7 8 -10 -5 0 5 10 15 20 25 30 Brine inlet temperature [...]

  • Page 18

    18 0 20 40 60 80 100 120 140 160 -10 -5 0 5 10 15 20 25 30 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 5 10 15 20 25 30 -10 -5 0 5 10 15 20 25 30 Brine inlet temperature in [°C] Power consumption (incl. power input to pump) 50 35 50 35 0 2 4 6 8 10 -10 -5 0 5 10 15 20 25 30 Brine inlet temper[...]

  • Page 19

    19 12.4.1 Control APPENDIX: 12.4 WIRING DIAGRAMS Mains system[...]

  • Page 20

    20  . 0  ) 0  ; 3( 9 $& +] 1HW ]   / / 3( / 0    7 7 7  .  ) 0     7 7 7 $ $ $ $ 1 1   12.4.2 Loa[...]

  • Page 21

    21  9 $& + ] ) 3( ,' $ 7 U )/  . $  )/ %& ; 5 % * * - 1 - - 5 % - % -  9'& %& *1' % % - - .RQWDN WRIIHQ  :3 JHVS HUUW 'LH )XQNWLRQ GHVWHQ[...]

  • Page 22

    12.4.4 Legend APPENDIX: 12.4 WIRING DIAGRAMS 22 A 1 Wire jumper across J5-ID3>X2 must be inserted if no utility company disable contactor is used A 2 Wire jumper , must be removed if 2nd disable input is used A 7 Wire jumper in SI 50/-70, in place of F18/F19 B2 * Pressostat low pressure, brine B3 * Thermostat, hot water (as an alternative to hot[...]

  • Page 23

    23 Hydraulic Block Diagram (Example) APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Immersion heater , hot water Primary circulating pump Heating circulating pump Heating circulating pump, heating circuit 2 Suppl. circulating pump Hot water circulating pump Mixer , heating circuit 3 Mixer , heating circuit 2 Controller unit External wall sensor Return sens[...]

  • Page 24

    24 APPENDIX: 12.6 EC DECLARA TION OF CONFORMITY EC Declaration of Conformity EC Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmbach / Allemagne hereby confirm that the design and construction of the product(s) listed below , in the ver sion(s) placed on the market b y us, con[...]

  • Page 25

    25 Notes[...]

  • Page 26

    26 Notes[...]

  • Page 27

    27 Notes[...]

  • Page 28

    28 Glen Dimplex Deutschland GmbH Subject to technical modifications Division Dimplex Fax +49 92 21 709-589 Am Goldenen Feld 18 ww w .dimplex.de D-95326 Kulmbach[...]