DeVillbiss Air Power Company SB-2-540 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of DeVillbiss Air Power Company SB-2-540, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DeVillbiss Air Power Company SB-2-540 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of DeVillbiss Air Power Company SB-2-540. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of DeVillbiss Air Power Company SB-2-540 should contain:
- informations concerning technical data of DeVillbiss Air Power Company SB-2-540
- name of the manufacturer and a year of construction of the DeVillbiss Air Power Company SB-2-540 item
- rules of operation, control and maintenance of the DeVillbiss Air Power Company SB-2-540 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DeVillbiss Air Power Company SB-2-540 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DeVillbiss Air Power Company SB-2-540, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DeVillbiss Air Power Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DeVillbiss Air Power Company SB-2-540.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the DeVillbiss Air Power Company SB-2-540 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Service Bulletin SB-2-540 OPERA TION MANUAL TRANS-TECH ® GRA VITY FEED SPRA YGUN English: Pages 2-9 MANUAL DE OPERACIÓN COMP ACT – PISTOLA PUL VERIZADORA POR GRA VEDAD TRANS-TECH ® Español: Páginas 10-17[...]

  • Page 2

    Page 2 SB-2-540 IMPORTANT: Read and follow all instruc- tions and SAFETY PRECAUTIONS before using this equipment. DESCRIPTION The Compact Gravity feed Spraygun Kit complies to ATEX regulations 94/9/EC, protection level; II 2 G X, Suitable for use in Zones 1 and 2 . IMPORTANT: These Sprayguns are suit- able for use with both waterbased and solvent b[...]

  • Page 3

    Page 3 SB-2-540 Patent No. 2372465 (GB) Ref. No. Description Part Number Qty. Options 1 Air Cap/Retaining ring COM-510 SP-100-510-K 1 +2 Nozzle SP-200S-**-K 1 14, 18, 22 e.g ** =14 =1.4 mm +3 Separator SP-626-K5 5 +4 Packing GTI-445-K2 2 5 Spreader Valve SP-403-K 1 6 Stud and Screw GTI-408-K5 5 7 Needle Adjusting Screw SP-614-K 1 +8 Spring SP-622-K[...]

  • Page 4

    Page 4 SB-2-540 INSTALLATION Important: To ensure that this equipment reaches you in first class condition, protective coatings have been used. Flush the equipment through with a suitable solvent before use. 1. Attach air hose to connector (13). Recommended hose size 8 mm bore. The hose must be conductive and electrical bond from the spraygun to ea[...]

  • Page 5

    Page 5 SB-2-540 1. Remove Adjusting Knob (7), Spring (8), and Needle (9). 2. Loosen Housing (10). 3. Remove Housing (10) and Airvalve Spring. 4. Remove Valve (11). 5. Using Service Tool SPN-7, engage groove behind the Valve Seat. 6. Remove Valve Seat. 7. Push out the Front Airvalve Seal with a finger. 8. Turn the Gun upside down and let the Seal fa[...]

  • Page 6

    Page 6 SB-2-540 12. Fit Valve Seat to Gunbody. 13. Remove Rear Airvalve Seal from housing (10) with a hooked instrument. 14. Fit new Seal to Service Tool. 15. Fit Seal to Housing (10). 16. Replace Valve (11). 17. Replace Valve Spring and screw in Housing (10). 18. Tighten Housing. 19. Fit Needle (9). 20. Fit Spring (8) and Knob (7). 21. Adjust Need[...]

  • Page 7

    Page 7 SB-2-540 *Most common problem. Left or right side horn holes plugged. Dirt on left or right side of fluid tip. Remedies for the top-heavy, bottom-heavy, right-heavy, and left-heavy patterns: 1. Determine if the obstruction is on the air cap or the fluid tip. Do this by making a test spray pattern. Then, rotate the cap one-half turn and spray[...]

  • Page 8

    Page 8 SB-2-540 Tighten. Replace cup gasket. Clean. Adjust gun or reduce fluid flow. Mix properly or apply light coats. Hold gun at right angle to work and adapt to proper gun technique. Check distance. Normally approx. 8". Reduce air pressure and check spray pattern. Follow paint manufacturer's mixing instrs. Check distance. Normally app[...]

  • Page 9

    Page 9 SB-2-540 NIOSH-Certified for respiratory protection in atmospheres not immediately dangerous to life. Consists of : 1 - Piercing Tool, 48 - Disposable Liners, 48 - Drain Bushings OMX-70-K48 Paint Cup Liner Kit Allows quick & easy clean-up. (1) Wall mount bracket included with GH-407. Holds standard paint cups, gravity feed guns and cups,[...]

  • Page 10

    Página 10 SB-2-540 IMPORTANTE: Lea y siga todas las instrucciones y Precauciones de Seguridad antes de utilizar este equipo. DESCRIPCIÓN El Kit de Pistola Pulverizadora por Gravedad Compact cumple las normas ATEX 94/9/CE, nivel de protección; II 2 G X, Adecuado para el uso en las Zonas 1 y 2 . IMPORTANTE: Estas Pistolas pulver- izadoras son apro[...]

  • Page 11

    Página 11 SB-2-540 Patente Nº 2372465 (GB) Nº Número Ref. Descriptión de Pieza Cant Opciones 1C asquillo de aire / Anillo de SP-100-510-K 1 retención COM-510 +2 Pico de fluido SP-200S-**-K 1 14, 18, 22 ej. ** =14 =1.4 mm +3 Separador SP-626-K5 5 +4 Empaquetadura GTI-445-K2 2 5 Válvula dispersora SP-403-K 1 6 Espiga y tornillo GTI-408-K5 5 7 [...]

  • Page 12

    Página 12 SB-2-540 INSTALACIÓN Importante: Para asegurarse de que este equipo llega a usted en condiciones óptimas, se han utilizado recubrimientos protectores. Enjuague el equipo con un disolvente adecuado antes de su uso. 1. Acople el manguito de aire al conector (13). Tamaño de manguito recomendado: 8 mm diám. interior. El manguito debe ser[...]

  • Page 13

    Página 13 SB-2-540 1. Retire el pomo de ajuste (7), el muelle (8), y la aguja (9). 2. Afloje el alojamiento (10). 3. Retire el alojamiento (10) y el muelle de la válvula de aire. 4. Retire la válvula (11). 5. Usando la herramienta de manteni-miento SPN-7, enganche la muesca detrás del asiento de la válvula. 6. Retire el asiento de la válvula.[...]

  • Page 14

    Página 14 SB-2-540 12. Coloque el asiento de válvula en el cuerpo de la pistola. 13. Retire la junta de la válvula de aire del alojamiento (10) con un instrumento que tenga gancho. 14. Instale una junta nueva en la herramienta de manten- imiento. 15. Coloque la junta en el alojamiento (10). 16. Vuelva a colocar el husillo (11). 17. Vuelva a colo[...]

  • Page 15

    Página 15 SB-2-540 *Problemas más comunes. Agujeros en el lado izquierdo o derecho de la horquilla obstruidos. Suciedad en el lado izquierdo o derecho de la punta del líquido. Corrección de los patrones pesados en la parte superior, inferior, el lado derecho e izquierdo. 1. Determine si la obstrucción está en el casquillo de aire o en la punt[...]

  • Page 16

    Página 16 SB-2-540 Apriete. Reemplace la guarnición de la cubeta. Limpie. Ajuste la pistola o reduzca el flujo de fluido. Mezcle debidamente o aplique capas livianas. Sostenga la pistola en un ángulo correcto para trabajar y adáptela a una técnica debida. Verifique la distancia. Normalmente, aprox. 8 pulg. Reduzca la presión de aire y verifiq[...]

  • Page 17

    Página 17 SB-2-540 Certificados por NIOSH para protección respira- toria en atmósferas que no implican riesgo inmediato para la vida. Compuesto por: 1 herramienta perforadora, 48 – forros desechables, 48 – Boquillas de descarga. Kit de forros de cubetas de pintura OMX-70-K48 Permite la limpieza rápida y fácil (1) Soporte de montaje mural i[...]

  • Page 18

    Page 18 SB-2-540 NOTES[...]

  • Page 19

    Página 19 SB-2-540 NOTAS[...]

  • Page 20

    Page 20 SB-2-540 ITW Industrial Finishing DeVilbiss has authorized distributors throughout the world. For tech- nical assistance or the distributor nearest you, see listing below. U.S./Canada Technical Service Office: 195 Internationale Blvd., Glendale Heights, IL 60139 Toll-Free Telephone: 1-888-992-4657 (U.S.A. and Canada only) Toll-Free Fax: 1-8[...]