Desa VYM27NR/PR manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa VYM27NR/PR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa VYM27NR/PR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa VYM27NR/PR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa VYM27NR/PR should contain:
- informations concerning technical data of Desa VYM27NR/PR
- name of the manufacturer and a year of construction of the Desa VYM27NR/PR item
- rules of operation, control and maintenance of the Desa VYM27NR/PR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa VYM27NR/PR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa VYM27NR/PR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa VYM27NR/PR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa VYM27NR/PR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    UNVENTED (VENT -FREE) GAS LOG HEA TER Also Design-Cer tified As A V ented Decorative Appliance OWNER’S OPERA TION AND INST ALLA TION MANUAL Patent Pending P I L O T O F F O N L O R E M O T E O F F HI FLAME-MAX ® Multi-Sided Log Design VYM27NR/PR FVFM27NR/PR Remote Control Ready Model Save this manual for future reference. WARNING: If the informa[...]

  • Page 2

    2 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working proper[...]

  • Page 3

    3 108382 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54 *. *Available from: American National Standards Institute, Inc. 1430 Broadway Ne[...]

  • Page 4

    4 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually [...]

  • Page 5

    5 108382 OWNER’S MANUAL For more information, visit www.desatech.com DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas[...]

  • Page 6

    6 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one[...]

  • Page 7

    7 108382 OWNER’S MANUAL For more information, visit www.desatech.com INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall. WARNING: Never install the heater • in a bedroom or bathroom un- less installed as a vented ap- [...]

  • Page 8

    8 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above both fireplace o[...]

  • Page 9

    9 108382 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Continued MANTEL CLEARANCES In addition to meeting noncombustible ma- terial clearances, you must also meet re- quired clearances between fireplace open- ings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below, you will [...]

  • Page 10

    10 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard again[...]

  • Page 11

    11 108382 OWNER’S MANUAL For more information, visit www.desatech.com 7. Mark screw locations through one hole on each side of the mounting bracket (see Figure 12). If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace. If installing optional control accessories, do so at [...]

  • Page 12

    12 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. CHECKING GAS CONNECTIONS INST ALLA TION Continued * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See[...]

  • Page 13

    13 108382 OWNER’S MANUAL For more information, visit www.desatech.com Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Fig- ure 15, page 12). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all[...]

  • Page 14

    14 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighte[...]

  • Page 15

    15 108382 OWNER’S MANUAL For more information, visit www.desatech.com 8. Keep contr ol knob pr essed in for 30 seconds after lighting pilot. After 30 seconds, release contr ol knob . • If contr ol knob does not pop out when released, contact a qualif ied service person or gas supplier f or repairs. Note: If pilot goes out, repeat steps 4 throug[...]

  • Page 16

    16 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com OPERA TING HEA TER Continued Figure 26 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA only) Figure 25 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation Selector Switch in Remote Position (Optional Rem[...]

  • Page 17

    17 108382 OWNER’S MANUAL For more information, visit www.desatech.com BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot. MAIN BURNE[...]

  • Page 18

    18 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUS[...]

  • Page 19

    19 108382 OWNER’S MANUAL For more information, visit www.desatech.com OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit White powder res[...]

  • Page 20

    20 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s p[...]

  • Page 21

    21 108382 OWNER’S MANUAL For more information, visit www.desatech.com SPECIFICA TIONS Natural Gas Propane/LP Btu (Variable) 20,000/39,000 20,000/39,000 Type Gas Natural Gas Only Propane/LP Only Ignition Piezo Piezo Pressure Manifold 3.5" W.C. 8.0" W.C. Inlet Gas Pressure (in. of water) Maximum 10.5" 14" Minimum* 5" 11&quo[...]

  • Page 22

    22 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN VYM27NR FVFM27NR VYM27PR FVFM27PR 5 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 1 9 3 2 13 12 15 14 18 17 12 12 16 21 12 19 6 8 7 4 11 12 20 10 9 23 22 NOTE: Part numbers 22 and 23 are for natural gas model only.[...]

  • Page 23

    23 108382 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST VYM27NR FVFM27NR VYM27PR FVFM27PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. PART NUMBER KEY VYM27NR VYM27PR NO. FVFM27NR FVFM27PR DESCRIPTION QTY. [...]

  • Page 24

    24 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International at 1-800-458-6860 for referral informa- tion. You can also write to the address listed on the back page of this manual. E[...]

  • Page 25

    25 108382 OWNER’S MANUAL For more information, visit www.desatech.com 1. Where will the product be used? ❍ Living/Family Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? ❍ Y es[...]

  • Page 26

    26 108382 UNVENTED GAS LOG HEA TER FLAME-MAX ® For more information, visit www.desatech.com 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required TM[...]

  • Page 27

    27 108382 OWNER’S MANUAL For more information, visit www.desatech.com NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ ________________________________________________________________________________[...]

  • Page 28

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED [...]