Desa VP1000BTA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa VP1000BTA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa VP1000BTA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa VP1000BTA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa VP1000BTA should contain:
- informations concerning technical data of Desa VP1000BTA
- name of the manufacturer and a year of construction of the Desa VP1000BTA item
- rules of operation, control and maintenance of the Desa VP1000BTA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa VP1000BTA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa VP1000BTA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa VP1000BTA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa VP1000BTA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Save this manual for future reference. BLUE FLAME VENT -FREE PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL 10,000 Btu/Hr Thermostatically- Controlled Models VP1000BT A WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of lif[...]

  • Page 2

    2 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by[...]

  • Page 3

    3 104266 OWNER’S MANUAL PRODUCT IDENTIFICA TION PRODUCT FEA TURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ig[...]

  • Page 4

    4 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually[...]

  • Page 5

    5 104266 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes[...]

  • Page 6

    6 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. Th[...]

  • Page 7

    7 104266 OWNER’S MANUAL Figure 5 - Mounting Screw Locations Mounting Screw Locations 8 7 / 8 " Minimum To Maintain 6" Clearance From Wall 7 3 / 4 " 20 1 / 4 " Minimum To Maintain 3" Clearance From Floor FLOOR JOINING WALL INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater . 2. Mark[...]

  • Page 8

    8 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching To Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounti[...]

  • Page 9

    9 104266 OWNER’S MANUAL Figure 13 - Gas Connection * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design- certified equipment shutoff valve from your dealer. See Accessory , page 18. Tee Joint Reducer Bushing to 1/8" NPT 1/8&quo[...]

  • Page 10

    10 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will dam[...]

  • Page 11

    11 104266 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Remove fr ont panel (see Figure 10, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights. 4. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, r el[...]

  • Page 12

    12 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® GRH/OV 008 BAD PILOT/LP INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will ca[...]

  • Page 13

    13 104266 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service per- son should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode positioned wrong 2. Ignitor electrode bro[...]

  • Page 14

    14 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® TROUBLESHOOTING Continued REMEDY 1. Clean burner orifice (see Cleaning and Maintenance , page 12) or replace burner orifice 2. Replace burner orifice 3. Contact local propane/LP gas company 1. Contact local propane/LP gas company 2. Clean burner orifice (see Cleaning and Maintenance , page [...]

  • Page 15

    15 104266 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, cal[...]

  • Page 16

    16 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® 12-2 12-1 ODS/PILOT ILLUSTRA TED PA R T S BREAKDOWN 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19 VP1000BT A[...]

  • Page 17

    17 104266 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual. P ARTS LIST KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembly 1 3 099318-04 Grill Guard 1 4 101108-01 Gri[...]

  • Page 18

    18 104266 PROP ANE/LP GAS HEA TER BLUE FLAME 10,000 BTU ® SPECIFICA TIONS VP1000BTA Btu(Variable) 5,000/10,000 Type Gas Propane/LP Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water) 14" Max. / 11" Min. Heater Dimensions (Includes knobs and grill) 21.5" (H) x 13.5" (W) x 7" (D) [...]

  • Page 19

    19 104266 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________[...]

  • Page 20

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased 104266-0[...]