A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa (V)3612ST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa (V)3612ST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa (V)3612ST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa (V)3612ST should contain:
- informations concerning technical data of Desa (V)3612ST
- name of the manufacturer and a year of construction of the Desa (V)3612ST item
- rules of operation, control and maintenance of the Desa (V)3612ST item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa (V)3612ST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa (V)3612ST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa (V)3612ST.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa (V)3612ST item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For more information, visit www .desatech.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.  ?[...]

  • Page 2

    www .desatech.com 1 15603-01C 2       -        [...]

  • Page 3

    www .desatech.com 1 15603-01C 3 PRODUCT DIMENSIONS 12 3 / 8 " Dia. I.D. (31.4cm) 9 1 / 2 " (24.1cm) 2 1 / 2 " (6.3cm) 15" Dia. O.D. (38.1cm) TOP VIEW 6" (15/2cm) Outside Air 37 1 / 2 " (95.2cm) 36 1 / 2 " (92.7cm) 15 1 / 2 " (39.3cm) 21 5 / 16 " (54.1cm) 4 1 / 2 " (1 1.4cm) 17 3 / 16 " (43.6cm)[...]

  • Page 4

    www .desatech.com 1 15603-01C 4 FIREPLACE INST ALLA TION   Back and sides of replace 1/2" min. Adjacent wall 12" min. Chimney outer pipe surfaces 2" min. Bo tt om of r ep la ce to  oor 0" min.   [...]

  • Page 5

    www .desatech.com 1 15603-01C 5 22 3 / 4 " (57.7cm) PLA TFORM MUST BE SOLID, FLA T , AND FULL Y SUPPORTED "Z" TYPE EMBER PROTECTOR (NOT SUPPLIED) AS REQUIRED BY DESIGN AS LONG AS CEILING CLEARANCE IS MAINT AINED 44 5 / 8 " (1 13.3cm) 53 7 / 16 " (135.7cm) MIN. Figure 6 - Framing Firebox with “Z” T ype Ember Protectors 2[...]

  • Page 6

    www .desatech.com 1 15603-01C 6 FIREPLACE INST ALLA TION Continued  Woodwork such as wood trims, mantels or any other combustible material projecting from Figure 12 - Mantel Clearances to Metal Face VENTING INST ALLA TION 8" Max. “K” Facto r .84 1 1 / 2 " T yp. 1 1 / 2 " T yp. No[...]

  • Page 7

    www .desatech.com 1 15603-01C 7 Figure 14 - Pipe Connection      V3612ST See-Through Fireplace 52 3 / 4 " 48-12DM 48-12TM Flue Pipe 46 5 / 8 " 36-12DM 48-12TM Flue Pipe 34 5 / 8 " 24-12DM 48-12TM Flue Pipe 22 5 / 8 " 18-12DM 48-[...]

  • Page 8

    www .desatech.com 1 15603-01C 8 2" (5.1cm) Minimum VENTING INST ALLA TION Continued OFFSET CHART Figure 17 - Chimney Supports Straps    A B 48"  18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 1 / 2 " 25 1 / 4 " 1 12 1 / 2 " [...]

  • Page 9

    www .desatech.com 1 15603-01C 9 VENTING INST ALLA TION Continued Figure 19 - Firestop Spacer with Living Space Above Ceiling Figure 20 - Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples (Min. of 8) Firestop Spacer Screws or Staples (Min. of 8) Existi ng Ceiling Frame Figure 21 - 10 Foot Rule ?[...]

  • Page 10

    www .desatech.com 1 15603-01C 10 VENTING INST ALLA TION Continued Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 24 - Flashing Installation   T o mai nt ai n a 1" cle ara nc e to pip e on a ro of wi th a pit[...]

  • Page 11

    www .desatech.com 1 15603-01C 11 Secure T ermination to Outer Pipe with 3 Screws RTL-12D Stainless Inner Flue Pipe Apply W aterproof Caulking Storm Collar Flashing Underlap Shingles Figure 26 - T erminations Overlap Shingles (T op and Sides of Flashing Base) VENTING INST ALLA TION Continued   ?[...]

  • Page 12

    www .desatech.com 1 15603-01C 12 refr acto ry cemen t or com merc ial furn ace ceme nt, Install the gas appl ianc e or cap off gas line if desired.      and connections must be tested for leaks after the installation is c om pl et ed . Af te r e ns ur in g that the gas valve[...]

  • Page 13

    www .desatech.com 1 15603-01C 13 Figure 31 - Bi-Fold Glass Doors Doors Fully Closed Fireplace Front Fireplace Front Doors Fully Opened      equipped with glass doors should be operated only with doors fully opened or doors fully    ?[...]

  • Page 14

    www .desatech.com 1 15603-01C 14 OPERA TION AND MAINTENANCE GUIDELINES Continued ways open mechanism when starting a re. This provides adequate outside combustion air . Close mechanism when not in use to prevent cold air from entering room. Periodi- cally check your outside air intake vent hood for any possible obstructions such as snow , bushes[...]

  • Page 15

    www .desatech.com 1 15603-01C 15   Black - 01244 Brass - 01245 Chrome - 01246         [...]

  • Page 16

    NOT A UPC 1 15603-01 Rev . C 12/08 115603 01 DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www .desatech.com 1-866-672-6040[...]