Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER should contain:
- informations concerning technical data of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER
- name of the manufacturer and a year of construction of the Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER item
- rules of operation, control and maintenance of the Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any o[...]

  • Page 2

    2 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at [...]

  • Page 3

    3 104256 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, In[...]

  • Page 4

    4 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways[...]

  • Page 5

    5 104256 OWNER’S MANUAL WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or applicable local codes. AIR FOR COMBUSTION AND VENTILA TION Conti[...]

  • Page 6

    6 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Width 18" 17" 14" 20" 24" 17" 14" 26" 30" 17" 14" 32" 36” 17” 14” 38” INSTALLATION AND CLEARANCES (Vent-Free Operation Only) Figure 4 - Minimum C[...]

  • Page 7

    7 104256 OWNER’S MANUAL INST ALLA TION Continued NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Op- eration, page 9[...]

  • Page 8

    8 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non- Combustible Material 8" Min. 12" 15" 18" All minimum distances are in inches Log Sets 18", 24", and 30" Models 20" 2 1 /2 " 6" 8" 10" 12" Distances to[...]

  • Page 9

    9 104256 OWNER’S MANUAL INST ALLA TION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non combustible material. If your heater is a manually controlled model, you may use this heater as [...]

  • Page 10

    10 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator be- twe[...]

  • Page 11

    11 104256 OWNER’S MANUAL INST ALLA TION Continued The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator wit[...]

  • Page 12

    12 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ON POSITION OFF POSITION INST ALLA TION Continued Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Checking Gas Joints Control Valve Location Propane Supply Tank Manual Shutoff Valve Pressure Testing Gas Supply Piping System Test Pressures In Excess O[...]

  • Page 13

    13 104256 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal in- jury. INSTALLING LOGS For Vintage Oak Model Each log is marked with a number. These numbers will help you ide[...]

  • Page 14

    14 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ 1. STOP! Read the safety inf ormation above. 2. Make sur e manual shutoff valve is fully open. 3. Press in and tur n control knob clock- wise Clockwise to the OFF position. Figure 23 - Pilot OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low t[...]

  • Page 15

    15 104256 OWNER’S MANUAL OPERA TING HEA TER Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and tur n control knob clock- wise Clockwise to the HIGH position. 2 . T urn the contr ol knob clockwise Clockwise to the PILOT position. 3. Press in control knob and tur n clock- wise Clockwise to the OFF Position. Shutting Off Burn[...]

  • Page 16

    16 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean[...]

  • Page 17

    17 104256 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit Moisture/condensation noticed on windows REMEDY 1. Contact local natural g[...]

  • Page 18

    18 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas su[...]

  • Page 19

    19 104256 OWNER’S MANUAL SPECIFICA TIONS Golden Oak Golden Oak Vintage Oak Vintage Oak and Birch and Birch 18" Variable 24" Variable 18" Variable 24 ” , 30 ” , and 36" Manually Manually Manually Variable Controlled Controlled Controlled Manually Controlled Btu (Variable) 16,000/27,000 16,000/31,500 16,000/30,000 20,000/39,[...]

  • Page 20

    20 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ™ VINTAGE OAK MODELS VYS18P AND VYS24P 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20-2 20-1 20 18 23 20-1 20-2 ODS Pilot[...]

  • Page 21

    21 104256 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. VYS18P VYS24P DESCRIPTION QTY. 1 102968-01 102968-02 Back Log (#1) 1 2 102969-01 102969-02 Front Log (#2) 1 3 102970-01 102970[...]

  • Page 22

    22 104256 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX™ ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ™ GOLDEN OAK AND BIRCH LOG MODELS VYD18P, VYBD18P, VYD24P, VYBD24P,VYD30P, VYBD30P, AND VYD36P 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19 17 1A 1B *Note: The Golden Oak Log (104254-01) for the VYD36P model differs slig[...]

  • Page 23

    23 104256 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. VYD18P VYBD18P VYD24P VYBD24P VYD30P VYBD30P VYD36P DESCRIPTION QTY. 1A 103517-01 – 102785-01 – 103519-01 – 104254-01 Lo[...]

  • Page 24

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED [...]