Desa RJ45 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa RJ45, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa RJ45 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa RJ45. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa RJ45 should contain:
- informations concerning technical data of Desa RJ45
- name of the manufacturer and a year of construction of the Desa RJ45 item
- rules of operation, control and maintenance of the Desa RJ45 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa RJ45 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa RJ45, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa RJ45.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa RJ45 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. Heater Sizes: RJ45 And RJ70[...]

  • Page 2

    2 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the ?[...]

  • Page 3

    3 104950 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - RJ45 Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Side Cover Ignition Control Assembly (assembly on inside of side cover) Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shel[...]

  • Page 4

    4 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 3 - Cross Section Operational View Fuel Filter Air Line To Burner Air Output Filter Air Pump Air Intake Filter Cool Air In Fan Combustion Chamber Ignitor or Spark Plug Motor Clean Heated Air Out Ignition Control Assembly or Electronic Ignitor Air For Fuel System Air For Combustion And Hea[...]

  • Page 5

    5 104950 OWNER’S MANUAL Item Fuel tank Air output and lint filters Air intake filter Fuel filter RJ45: Ignitor RJ70: Spark Plug Fan blades Motor WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- qui[...]

  • Page 6

    6 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 TROUBLESHOOTING RJ45 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. Check circuit breaker in electrical panel 2. Check all electrical connections. See W iring Diag rams, page 12 3. If fan does not turn freely , see [...]

  • Page 7

    7 104950 OWNER’S MANUAL TROUBLESHOOTING Continued RJ70 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. OBSERVED FAULT Heater ignites, but flame-out control shuts off heater after a short period of time Heater will not ignite, but motor runs for a short period of time Motor does[...]

  • Page 8

    8 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Opera tion , page 5). Al- low motor to reach full speed. 4. Using a flat blade screwdriver , adjust pressure. T urn relief valve to righ[...]

  • Page 9

    9 104950 OWNER’S MANUAL Fuel Filter Side Cover Upper Fuel Line Figure 9 - Fuel Filter Removal FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver (see Figure 9). 2. Remove side cover . 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel an[...]

  • Page 10

    10 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 NOZZLE (RJ45) 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fa n , page 8). 3. Remove fuel and air line hoses from nozzle adapter . 4. T urn nozzle adapter 1/4 turn to left and pull toward motor to remove. 5 . Place nozzle adapter into vise and lightly tighten. 6 [...]

  • Page 11

    11 104950 OWNER’S MANUAL Sandpaper Figure 22 - Sanding Rotor Figure 21 - Gap Adjusting Screw Locations Figure 20 - Rotor Location O TOR PFA/P 056 Insert Rotor Air Output Filter Blade Pump Plate Air Intake Filter Filter End Cover Fan Guard 0.08/0.10 mm Gap Measured With Feeler Gauge Blade Rotor Gap Adjusting Screw Gap Adjusting Screw SER VICE PROC[...]

  • Page 12

    12 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 23- Wiring Diagram For RJ70 WIRING DIAGRAMS Figure 22- Wiring Diagram For RJ45 White Photo- cell Black Blue Flame- Out Control B Reset Button R Red Blue White Spark Plug Green/ Yellow Black Power Plug 100V/50 or 60 Hz Green White White White Red Green Terminal Board Ignitor Plug Receptac[...]

  • Page 13

    13 104950 OWNER’S MANUAL ACCESSORIES Purchase accessories and parts from your nearest dealer. AIR GAUGE KIT - HA1180 Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. A 008 IGNITION CONTROL ASSEMBLY/PHOTOCELL TESTER - HA1170 Special tool[...]

  • Page 14

    14 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9-1 9-2 9-3 9-4 9-5 17 18 19 20 21 22 23 24 25 26 27 28 29 30 34 35 36 32 38 33 31 42 41 40 39 37 ILLUSTRA TED P ARTS BREAKDOWN RJ45 Motor and Pump Assembly 12-1 12-2 12-18 12-4 12-3 12-17 12-16 12-5 12-6 12-15 12-8 12-9 12-10 12-7 12-14 12-13 12-11 12-12[...]

  • Page 15

    15 104950 OWNER’S MANUAL P ARTS LIST RJ45 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-36 Upper Shell 1 3 M11[...]

  • Page 16

    16 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 ILLUSTRA TED P AR TS BREAKDOWN RJ70 40 41 43 5 47 46 2 4 3 6 7 8 10 11 12 12 14 18 21 22 24 27 28 29 30 31 32 34 38 37 19 13 9 33 35 36 42 39 23 44 45 1 26 15 17 20 16 25 48 10-1 18-1 18-18 18-2 18-3 18-4 18-17 18-16 18-15 18-14 18-7 18-6 18-5 18-8 18-9 18-10 18-11 18-12 18-13 Motor and Pump As[...]

  • Page 17

    17 104950 OWNER’S MANUAL P ARTS LIST RJ70 ∆ Not available as an assembly ** Included in Rotor Kit (Part No. HA3004) ⊕ Included in Filter Kit (Part No. HA3014) ∞ Included in Pump Adjustment Kit (Part No. HA3020) KEY PART PART NO. NUMBER DESCRIPTION QTY. 18-17 M8643** Blade 4 18-18 FHPF3-5C Screw, #10-32 x 5/8" 2 19 M50050 Rubber Cap 1 2[...]

  • Page 18

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship. If so, DESA International will repair or replace the heater without c[...]