Desa LCF24 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa LCF24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa LCF24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa LCF24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa LCF24 should contain:
- informations concerning technical data of Desa LCF24
- name of the manufacturer and a year of construction of the Desa LCF24 item
- rules of operation, control and maintenance of the Desa LCF24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa LCF24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa LCF24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa LCF24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa LCF24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any[...]

  • Page 2

    www .desatech.com 1 15043-01C 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier . W ARN ING [...]

  • Page 3

    www .desatech.com 1 15043-01C 3 W ARNING: This appliance is equipped for natural gas. An opti onal pr opan e/LP conv ersi on kit must be installed for use with propane/LP gas. W ARNING: Do not allow fans to b low dir ect ly into t he fire pl ace . A void any drafts th at alter bu rne r flame patterns. W ARNING: Installed decora- tive glass door e[...]

  • Page 4

    www .desatech.com 1 15043-01C 4 1. If you smell gas • shut off gas supply • do not try to light any appliance • do not tou ch any elec tric al swit ch; do not use any pho ne i n yo ur b uil ding • immediately call your gas supplier from a neighbor ʼ s phone. Follow the gas supplier ʼ s instructions • if you cannot reach your gas supplie[...]

  • Page 5

    www .desatech.com 1 15043-01C 5 UNP ACKING CA UTI ON: Do not re move th e data plates from the burner pan. The data plates contain impor- tant product information. 1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment. 3. Check all items for any shipping damage.[...]

  • Page 6

    www .desatech.com 1 15043-01C 6 The fireplace must include a working flue and vent ing syst em with the min imum open ings show n in the Figure 2. INST ALLA TION Continued Figure 2 - T echnical Information Charts Model Burner Descrip- tion BTU Input (Natural Gas) Min. V ent Opening LCF18 18" Dual 55,000 8" LCF24 24" Dual 60,000 8&q[...]

  • Page 7

    www .desatech.com 1 15043-01C 7 CAUT ION: Use only ne w , black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of volume will occur . Installation must include a equipment shu[...]

  • Page 8

    www .desatech.com 1 15043-01C 8 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Clos e e quip ment shu tof f valv e (s ee F igu re 5 ). 2. Pressurize supply piping system by either us - ing compressed air or opening main gas valve located on or near gas meter . 3. Check all joints from gas meter to equipment shutoff valve (see Figure 5[...]

  • Page 9

    www .desatech.com 1 15043-01C 9 INST ALLA TION Continued OPTIONAL GA9050A ON/OFF SAFETY V AL VE/PILOT KIT For additional convenience and safety , or for propane/LP conversion, an optional ON/OFF safety valve/pilot kit is available. See Accessories , page 18. W ARNING: Y ou must use a ON/OFF safety valve/pilot kit for propane/LP conversion. TESTING [...]

  • Page 10

    www .desatech.com 1 15043-01C 10 INST ALLA TION Continued Figure 1 1 - Installing T op Logs Figure 10 - Installing Middle Logs OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: Keep flue open when operating unit. W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage,[...]

  • Page 11

    www .desatech.com 1 15043-01C 1 1 Shutting Off Appliance T urn gas shutoff valve clockwise to the OFF position. CURING LOGS During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not [...]

  • Page 12

    www .desatech.com 1 15043-01C 12 CLEANING AND MAINTENANCE • Keep the area around the log set clean and clear of debris. • Occasionally , you may use a soft bristle brush to clean logs. • Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace. SERVICE HINTS When Gas Pressur[...]

  • Page 13

    www .desatech.com 1 15043-01C 13 TROUBLESHOO TING W ARNING: T urn off log set and let cool before servicing. Only a qualified service person should service and repair log set. Note: All troubleshooting items are listed in order of operation. POSSIBLE CAUSE 1. Poor fuel quality 2. Fireplace venting system not drafting properly 3. Exc ess ive flam [...]

  • Page 14

    www .desatech.com 1 15043-01C 14 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Ga s sup pl y tu rne d of f or eq uip- ment sh utof f valv e cl ose d 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. A i r in g a s l i n es w h e n i n- stalled 5 . Pilot adjustment screw closed 6. Pilot is clogged 7. Low [...]

  • Page 15

    www .desatech.com 1 15043-01C 15 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Me tal exp and ing whi le he at ing or c ont ract ing whil e c ooli ng 1. Log Set burning vapors from paint, hair spray , glues, clean - ers, chemicals, new carpet, etc. (See IMPOR T ANT state- ment above) 2 . Gas leak. S e e Wa r n i n g statement at top of page 1 . Gas [...]

  • Page 16

    www .desatech.com 1 15043-01C 16 ILL USTRA TED P ARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17[...]

  • Page 17

    www .desatech.com 1 15043-01C 17 P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY NO. P ART NUMBER DESCRIPTION QTY . LCF18 LCF24 1 901056-01 901056-01 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 901059-01 3/8 FLR x 3/8 FPT Ad[...]

  • Page 18

    www .desatech.com 1 15043-01C 18 ACCESSORIES Purchase these log set accessories from your local deal er . If they can not supply thes e accesso rie s, call DESA at 1-866-67 2-6040 for referral informatio n. Y ou can also write to the addres s listed on the back page of this manual. EQUIPMENT SHUTOFF V AL VE GA5010 For all models. Equipment shutoff [...]

  • Page 19

    www .desatech.com 1 15043-01C 19 NO TES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________[...]

  • Page 20

    2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 15043-01 Rev . C 06/05 115043 01 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory . W e reserve the right to amend these specifications at any time with[...]