Delta A08184 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta A08184, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta A08184 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta A08184. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta A08184 should contain:
- informations concerning technical data of Delta A08184
- name of the manufacturer and a year of construction of the Delta A08184 item
- rules of operation, control and maintenance of the Delta A08184 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta A08184 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta A08184, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta A08184.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta A08184 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION MANUAL P ART NO. A08184 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (66-651-1) ESP AÑOL: PÁGINA 27 FRANÇAIS: P AGE 53[...]

  • Page 2

    2- ENG A08184 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor [...]

  • Page 3

    3- ENG A08184 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fir e How T o Prevent It What Could Happen It is no[...]

  • Page 4

    4- ENG A08184 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause pr operty damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin a[...]

  • Page 5

    5- ENG A08184 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr[...]

  • Page 6

    6- ENG A08184 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will r emain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenanc[...]

  • Page 7

    7- ENG A08184 Revie w and underst and all inst ruction s and warnings in this manu al. Becom e famil iar with the opera tion and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacle s. Keep childr en away fr om the air compr essor at all times . Do not operate the produ ct when fatig ued or under the inf[...]

  • Page 8

    8- ENG A08184 GLOSSAR Y DUTY CYCLE Accessories for this unit ar e available at the store the unit was purchased. ACCESSORIES Become familiar with these terms befor e operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per squar e inch gauge; a unit of measure of pr[...]

  • Page 9

    9- ENG A08184 Assemble Wheels It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip. 1. Attach wheels with shoulder bolts and nuts as shown. 2. Tighten securely . NOTE : The outfit will sit level if the wheels are properly installed. The wheels and handle do not[...]

  • Page 10

    10- ENG A08184 INST ALLA TION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cord having a grounding wire with an appropriate gro[...]

  • Page 11

    11- ENG A08184 Extension Cords Use extra air hose instead of an extension cord to avoid voltage dr op and power loss to the motor , and to pr event overheating. If an extension cor d must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product • in goo[...]

  • Page 12

    12- ENG A08184 Description of Operation Become familiar with these contr ols before operating the unit. On/Auto/Off Switch : T ur n this switch "ON/AUTO" to pr ovide automatic power to the pr essure switch and "OFF" to r emove power at the end of each use. Pressur e Switch: The pr essure switch automatically starts the motor whe[...]

  • Page 13

    Before Starting Break-in instructions Serious damage may r esult if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been r eplaced. 1. Make sure the On/Auto/Off lever is in the "OFF" position. [...]

  • Page 14

    14- ENG A08184 How to Start: 1. T ur n the On/Auto/Of f lever to "ON/AUTO" and allow tank pressur e to build. Motor will stop when tank pr essure reaches "cut-out" pressur e. 2. T ur n r egulator knob clockwise to increase pressur e and stop when desired pressur e is r eached. The compressor is ready for use. NOTE: Always operat[...]

  • Page 15

    15- ENG A08184 NOTE: See "Operation" section for the location of controls. T o ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepar ed and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basi[...]

  • Page 16

    16- ENG A08184 Air Compressor Pump Intake and Exhaust V alves Once a year have a T rained Service T echnician check the air compressor pump intake and exhaust valves. If it is dirty , replace it with a new filter . On some models,the filter may be removed by using a pair of needle nose pliers or a scr ewdriver . Pull or pry out the old filter and c[...]

  • Page 17

    17- ENG A08184 8. Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise). 9. Replace the pressur e release tube. Tighten nuts. 10. Replace the outlet tube and tighten nuts. 11. Perform the Break-in Procedur e. See "Break-in Procedur e" in the Operation section. T o Replace Regulator 1. Release all air pr essu[...]

  • Page 18

    18- ENG A08184 STORAGE Before you store the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "OFF". 3. T ur n the r egulator counterclockwise and set the outlet pressur e to zero. 4. Remove [...]

  • Page 19

    19- ENG A08184 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off mot[...]

  • Page 20

    20- ENG A08184 PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section. NOTE: Adjust the r egulated pressur e[...]

  • Page 21

    21- ENG A08184 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped. 1. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch [...]

  • Page 22

    22- ENG A08184 AIR COMPRESSOR DIAGRAM T orque 5-7 ft.-lbs. 5 24 26 27 28 25 9 10 21 15 17 6 10 11 14 18 4 3 T o rque 9-12 ft.-lbs. 2 1 T orque 15-25 ft.-lbs. 32 31 T o rque 100-120 in.-lbs. 8 29 30 19 23 22 5 20[...]

  • Page 23

    23- ENG A08184 P AR TS LIST Key Part No. Number Description 1 ACG-408 Fastener Assembly (2) 2 AC-0376 Mini Shroud 3 91895680 Screw 1/4-20 x 3/4 (2) 4 ACG-18 Cup, Saddle Mount (2) 5 CAC-60 Shoulder Bolt (2) 6 AC-0774 Isolator (3) 8 AC-0605-1 Outlet T ube 9 SSP-7811 Nut Sleeve Assembly 1/4" 10 Z-D23004 Gauge (2) 11 SSP-6021 Reducer Bushing 1/8-1[...]

  • Page 24

    24- ENG A08184 AIR COMPRESSOR PUMP DIAGRAM T orque 51-63 in.-lbs. T o rque 100-120 in.-lbs. T orque 100-120 in.-lbs. T o rque 7-10 ft.-lbs. T o rque 42-48 in.-lbs. 83 84 85 90 89 87 81 80 91 78 72 70 74 73 76 79 92 93 77 88[...]

  • Page 25

    25- ENG A08184 P AR TS LIST KEY P ART NO. NO. DESCRIPTION 70 SSF-586 Screw 1/4-20 x 3/4 72 AC-0108 Fan 73 SSF-615 Screw 1/4-20 UNC-2A THD 74 Z-AC-0107 Eccentric Bearing Assembly 76 Z-D27268 Motor 77 D28993 Shim ✓ * 78 ----- Cylinder Sleeve ✓ 79 ----- Connecting Rod Assembly ✓ * 80 SSG-8156 O-Ring 81 Z-AC-0032 V alve Plate Assembly ✓ * 83 AC[...]

  • Page 26

    26- ENG A08184 A08184 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressur e washers, and generators, which have the following warranty per[...]