Delta Electronics Series S48SA manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics Series S48SA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics Series S48SA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics Series S48SA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics Series S48SA should contain:
- informations concerning technical data of Delta Electronics Series S48SA
- name of the manufacturer and a year of construction of the Delta Electronics Series S48SA item
- rules of operation, control and maintenance of the Delta Electronics Series S48SA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics Series S48SA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics Series S48SA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics Series S48SA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics Series S48SA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DA T ASHEET DS_S48SA1R812_06 012006 Delta Electronics, Inc. Delphi Series S48SA, 33W Family DC/DC Power Modules: 48V in, 1.8V/12A out The Delphi Series S48SA, surface mountable, 48V input, single output, isolated DC/DC converter is the latest offeri ng from a world leader in power system and technology and manu facturing – Delta Electronics, Inc.[...]

  • Page 2

    DS_S48SA1R812_06012 006 TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vou t unless otherwise noted.) PARAMETER NOTES and CONDITIONS S48SA1R812NRFA Min. Ty p. Max. Units ABSOLUTE MAXIMUM RA TINGS Input Voltage Continuous 80 Vdc Transient (100ms) 100ms 100 Vdc Operating Temperature Refer to Figure 18 for measuring p[...]

  • Page 3

    DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES 55 60 65 70 75 80 85 90 95 12 345 67 89 1 0 1 1 1 2 O U TPU T C U R R E N T (A ) E FFICIE NCY ( % ) 36Vin 48Vin 75Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 123456 789 1 0 1 1 1 2 O UT PUT CU RRE NT (A ) P O WE R DIS S IP A TIO N ( W) 36Vin 48Vin 75Vin Figure 1: Efficiency vs. load curr ent for[...]

  • Page 4

    DS_S48SA1R812_06012 006 4 ELECTRICAL CHARACTERISTICS CURVES Figure5 : Turn-on transie nt at zero load current (1 ms/div). Top Trace: Vout (500mV/div); Bottom Trace: ON/OFF Control (5V/div). Figure 6: Output voltage response to step-change in load current (50%-75% of Io, max; di/dt = 0.1A/ µs). Load cap: 10µF, 100 m Ω  ESR tantalum capacitor [...]

  • Page 5

    DS_S48SA1R812_06012 006 ELECTRICAL CHARACTERISTICS CURVES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 9 : Input Reflected Ripple Current, i s , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 33 µ F electrolytic capacito r (2 mA/div). Figure 10: Output voltage noise and ri pple measurem en[...]

  • Page 6

    DS_S48SA1R812_06012 006 This power module is not internally fused. To a chieve optimum safety and system protection, an input line fuse is highly recommended. T he safety agencies require a normal-blow fuse with 3A maximum rating to be installed in the ungrounded le ad. A lower rated fuse can be used based on the maximum inru sh transient energy an[...]

  • Page 7

    DS_S48SA1R812_06012 006 Vo(+) Vi(+) Vo(-) Sense(-) Sense(+) Vi(-) ON/OFF Figure 13: Remote on/off implementation Remote Sense (Optional) Remote sense compensates for voltage drop s on the output by sensing the actual output voltage at the p oint of load. The voltage between the remote sense pins and the output terminals must not exce ed the output [...]

  • Page 8

    DS_S48SA1R812_06012 006 [] ΚΩ − ∆ = − 104 % Vo up − ∆ + 1089 %) 100 ( 8 . 23 Vo Ex. When trim-up +10% (1.8V X 1.1 = 1.98V) Rtrim [] ΚΩ = − = − 9 . 48 104 10 up − + 1089 ) 10 100 ( 8 . 23 are should be taken to ensure th at the maximum utput Voltage Adjustment (TRIM) o increase or decrease the output voltage set point, the Rtri[...]

  • Page 9

    DS_S48SA1R812_06012 006 9 THERMAL CONSIDERATIONS Thermal management is an im porta nt part of the system design. To ensure proper, reliable operation, sufficie nt cooling of the power module is neede d over the entire temperature range of the modul e. Co nvection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment [...]

  • Page 10

    DS_S48SA1R812_06012 006 10 PICK AND PLACE LOCATION SURFAC E-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD)[...]

  • Page 11

    DS_S48SA1R812_06012 006 Temp . Time 150 ℃ 200 ℃ 100~140 sec. T ime Limited 9 0 sec. above 217 ℃ 217 ℃ Preheat time Ramp up max. 3 ℃ /sec. Ramp down max. 4 ℃ /s ec. Peak Tem p . 240 ~ 245 ℃ 25 ℃ Note: The temperature refers to the pin of S48SA, measured on the pin +Vout joint. 11 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE T ime ([...]

  • Page 12

    DS_S48SA1R812_06012 006 MECHANICAL DRAWING SMD Through-Hole Pin No. Name Function 1 +Vout Positive output voltage 2 -Vout Negative output voltage 6 Trim Output voltage trim 8 ON/OFF ON/OFF logic 11 -Vin Negative input voltage 12 +Vin Positive input voltage Optional Pin Name Function 4 +Sense (Option) Positive sense pin 5 9 -Sense (Option) NC Negati[...]

  • Page 13

    DS_S48SA1R812_06012 006 14 PART NUMBERING SYSTEM S 48 S A 1R8 12 N R F A* Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Type Option Code S- Small Power 48V S- Single A- Advanced 1R2-1.2V 1R5-1.5V 1R8-1.8V 2R5-2.5V 3R3- 3.3V 050- 5.0V 120- 12V 03- 3.0V 06- 6.6A 10- 10A 12- 12A N- Negative P[...]