Delta Electronics ND Series manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics ND Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics ND Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics ND Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics ND Series should contain:
- informations concerning technical data of Delta Electronics ND Series
- name of the manufacturer and a year of construction of the Delta Electronics ND Series item
- rules of operation, control and maintenance of the Delta Electronics ND Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics ND Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics ND Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics ND Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics ND Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRELIMINARY DATA SHEET DS_ND1 2S50A _07172008 FEATURES  High efficiency: 92.5% @ 12Vin, 3.3V/50A out y Size: 61.0x31.8x10.2mm (2.40”×1.25”×0.40”)  V olt age and resistor-based trim  No minimum load required  Output voltage programmable from 0.9Vdc to 3.63Vdc via external resistors  Fixed frequency operation  Single-in line[...]

  • Page 2

    DS_ND12S10A_07 172008 2 TECHNICAL SPECIFICA TIONS (Ambient T emperature=25°C, minim um airflow=200LFM, no minal V in =12Vdc unless otherw ise specified.) PA R A M E T E R NOTES and CONDITIONS ND12S0A0V50 (S tandard) Min. T yp. Max. Units ABSOLUTE MAXIMUM RA TINGS Input V oltage -0.3 13.8 Vdc Operating T emperature Refer to Figure 32 for the mea su[...]

  • Page 3

    DS_ND12S10A_07 172008 3 ELECTRICAL CHARACTERISTICS CUR VES 70 75 80 85 90 95 5.01 10 15 20 25 30 35 40 45 50 OUTPUT CURRE NT (A) EFFICIENCY (%) 10.2 12.0 13.8 70 75 80 85 90 95 5.01 10 15 20 25 30 35 40 45 50 OUTPUT CURRE NT (A) EFFICIENCY (%) 10.2 12.0 13.8 Figure 1: Converter efficiency vs. output current (0.9V output voltage) Figure 2: Converter[...]

  • Page 4

    DS_ND12S10A_07 172008 4 ELECTRICAL CHARACTERISTICS CUR VES (CON.) Figure 7: Output ripple & noise at 12V in, 0.9V/50A out Figure 8: Output ripple & noise at 12V in, 1.2V/50A out Figure 9: Output ripple & noise at 12V in, 1.5V/50A out Figure 10: Output ripple & noise at 12Vin, 1.8V/50A out Figure 1 1: Output ripple & noi se at 12[...]

  • Page 5

    DS_ND12S10A_07 172008 5 ELECTRICAL CHARACTERISTICS CUR VES (CON.) Figure 13: T urn on delay time at 12Vin, 0.9V/50A out Ch1: V o ut Ch4: Vin Figure 1 4: T urn on delay time Remote On/Off, 0.9V/50A out Ch1: V o ut Ch4: Enable Figure 15: T urn on delay time at 12Vin, 3.3V/50A out Ch1: V o ut Ch4: Vin Figure 1 6: T urn on delay time at Remote On/Off, [...]

  • Page 6

    DS_ND12S10A_07 172008 6 Figure 19: T y pical transient response to step load cha nge at 10A/ μ S from 50%to 75% and 75% to 50 of Io, max at 12Vin, 1.5V out Figure 20: T y pical transient response to step load cha nge at 10A/ μ S from 50%to 75% and 75% to 50 of Io, max at 12Vin, 1.8V out Figure 21: T y pical transient response to step load cha nge[...]

  • Page 7

    DS_ND12S10A_07 172008 7 DESIGN CONSIDERA TIONS The ND 50A uses two phase and volt age mode controlled buck topology . The output can be trimmed in the range of 0.9Vdc to 3.63Vdc with a resist or from T rim pin to Ground. A remote sense function is provided and it is able to compensate for a drop from the o utput of converter to point of load. The c[...]

  • Page 8

    DS_ND12S10A_07 172008 8 FEA TURES DESCRIPTIONS (CON.) Input Under-V oltage Lockout The input under-voltag e lockout prevents the converte r from being damaged while operating when the input voltage is too lo w . The lockout occurs between 7.6V to 9.0V . Over-Current and Short-Circuit Protection The ND series modules have non-l atching over-current [...]

  • Page 9

    DS_ND12S10A_07 172008 9 Output Capacit ance an external output capacitor(mi n 680uF) is required for stable operation. V olt age Margining Adjustment Output voltage margi n adjusting can be impleme nted in the ND modules by con necting a resi stor , R margin-up , from the T rim pin to the Ground for margining up the output voltage. Also, the output[...]

  • Page 10

    DS_ND12S10A_07 172008 10 THERMAL CUREVES ` Figure 32: T emperature measurement locati on* The allowed maximu m hot spot t emper ature is defin ed at 124 ℃ ND12S0A0V50(standar d) Outp ut Current vs. A mbient T emperature a nd Air V elocity @Vin=12V V out=0.9V ( Through P CB Orientat ion) 0 5 10 15 20 25 30 35 40 45 50 55 25 30 3 5 40 45 5 0 55 60 [...]

  • Page 11

    DS_ND12S10A_07 172008 11 MECHANICAL DRA WING VERTICAL THERMAL CUREVES ND12S0A0V50(standar d) Outp ut Current vs. A mbient Tem perat ure and A ir Velocity @Vin=12V V out=3.3V ( Through P CB Orientation) 0 5 10 15 20 25 30 35 40 45 50 55 25 30 3 5 40 45 5 0 55 60 65 70 75 80 85 Natu ral Convect ion O utput Current (A) Ambi en t T emp er atu re ( ℃ [...]

  • Page 12

    DS_ND12S10A_07 172008 12 P ART NUMBERING SYSTEM MODEL LIST Model Name Packaging Input V oltage Output V olta ge Output Current Efficiency 12Vin @ 100 % load ND12S0A0V50PNF A V ertical 10.2 ~ 13.8Vdc 0.9 V ~ 3.63Vdc 50A 92.5% CONT ACT : www .delt a.com.tw/dcdc USA: T elephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964[...]