Delta Electronics LCP-1250A4FSR manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics LCP-1250A4FSR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics LCP-1250A4FSR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics LCP-1250A4FSR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics LCP-1250A4FSR should contain:
- informations concerning technical data of Delta Electronics LCP-1250A4FSR
- name of the manufacturer and a year of construction of the Delta Electronics LCP-1250A4FSR item
- rules of operation, control and maintenance of the Delta Electronics LCP-1250A4FSR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics LCP-1250A4FSR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics LCP-1250A4FSR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics LCP-1250A4FSR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics LCP-1250A4FSR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DEL T A ELECT RONICS, INC. 1 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om RoHS Compliant Small Form Factor Pluggable T r ansceiver for Gigabit Ethernet and Fiber Channel FEATURES z Compliant with SFP T ranscei ver MSA specification z Compliant with Specifications fo r IEEE 802.3z/ Gig ab it Ethernet z LCP-1250Bxxx compliant w ith the 1.0625GBd Fi[...]

  • Page 2

    DEL T A ELECT RONICS, INC. 2 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Absolute Maximum Ratings Parameter Symbol Min. T yp. Max. Unit Note S torage T emper ature T s -40 85 ºC Supply V oltage V CC 0 5 V Recommended Operating Con ditions Parameter Symbol Min. T yp. Max. Unit Note Case Operating T e mperature T C -5 70 ºC See order information[...]

  • Page 3

    DEL T A ELECT RONICS, INC. 3 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Optical Characteristics (LCP-1250A4FSR) (V CC =3.135V to 3.465V , Data Rate=1.25Gb/sec, PRBS=2 7 -1 NRZ, 50/125 μ m MMF) Parameter Symbol Min. T yp. Max. Unit Note Transmitter Output Optical Power (A v g.) P O -9 -3 dBm Optical Extinction Ratio ER 9 dB Center Wavelength λ[...]

  • Page 4

    DEL T A ELECT RONICS, INC. 4 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Optical Characteristics (LCP-1250B4QSR) (V CC =3.135V to 3.465V , Data Rate=1.25Gb/sec, PRBS=2 7 -1 NRZ, 9/125 μ m SMF) Parameter Symbol Min. T yp. Max. Unit Note Transmitter Output Optical Power (A v g.) P O -9.5 -3 dBm Optical Extinction Ratio ER 9 dB Center Wavelength ?[...]

  • Page 5

    DEL T A ELECT RONICS, INC. 5 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Num. Name Function Plug Seq. Notes 1 VeeT Transmitter Ground 1 2 T X Fault Transmitter Fault Indication 3 Note 1 3 TX Disable Transmitter Disable 3 Note 2 Module disables on hi gh or open 4 MOD-DEF2 Module D[...]

  • Page 6

    DEL T A ELECT RONICS, INC. 6 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10K  resistor on the host board. Pull up voltag e between 2.0V and VccT, R+0.3V. Wh en high, output indicates a laser fault of some kind. Low indicates normal operation. In th[...]

  • Page 7

    DEL T A ELECT RONICS, INC. 7 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Recommend Circuit Schematic Laser Diode Photo D iode 1uH 1uH 0.1uF 10uF 0.1uF 0.01uF 0.01uF 0.01uF 0.01uF 0.1uF 10uF RES1 RES1 100 Ohms* RES1 RES1 RES1 10k Ohms 100 Ohms VCC Protocol Vcc SerDes IC Protocol IC PLD / PAL Mod_def 2 Mod_def 1 Mod_def 0 3.3V 3.3V DELTA SFP Modul[...]

  • Page 8

    DEL T A ELECT RONICS, INC. 8 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Package Outline Drawing for Met al Housing with Bail de-latch[...]

  • Page 9

    DEL T A ELECT RONICS, INC. 9 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om SFP timin g p arameters for SFP management Parameter Symbol Min. Max. Unit Unit Conditions TX_DISABLE Assert time t_off 10 μ sec T ime from rising edge of TX_DISABLE to when the optical output fa lls below 10% of nominal TX_DISABLE Negate time t_on 1 msec T ime from fallin[...]

  • Page 10

    DEL T A ELECT RONICS, INC. 1 0 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om SFP timin g p arameters Power on initialization of SFP t ransceiver, TX_DISABLE negated Power on initialization of SFP, TX_DISABLE asserted Initializa tion during hot plu gging of SFP TR ANSCEIVER . Example of initialization during hot plugging, TX_DISABLE negated. SFP TX[...]

  • Page 11

    DEL T A ELECT RONICS, INC. 1 1 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om LCP-1250A4FSR EEPROM Serial ID Memory Content s (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCI I Address Hex ASCII Addres s Hex ASCII Addre ss Hex ASCII 00 03 25 20 50 46 F 75 SN 100 00 125 00 01 04 26 20 51 53 S 76 SN 101 00 126 00 02 07 27 20 [...]

  • Page 12

    DEL T A ELECT RONICS, INC. 1 2 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om 5) Byte 128-255 had been set hex. 00. Regulatory Compliance Featur e Referenc e Performance Electromagnetic Inte rference (EMI) FCC CR F 47, Part15 C lass B EN 55022 Class B (CISPR 22A) Radio Frequency Electromagnetic Field EN 61000-4-3 IEC 61000-4-3 Elect rosta tic Disch[...]

  • Page 13

    DEL T A ELECT RONICS, INC. 1 3 N o v . , 2 0 0 6 Rev . 0 C www .delt aww.c om Ordering information for SFP mod ule s LCP-1250X 1 4X 2 SRX 3 X 1 : Fiber A : Multi-mode 850nm B : Single-mode 1310nm X 3 : T emperature Blan k : -5 to +70 degree C H : -10 to +85 degree C T : -40 to +85 deg ree C X 2 : Dist ance F : 500m (Multi-m ode 850nm ) Q : 10km (Si[...]