Delta Electronics LCP-10G3B4EDR manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics LCP-10G3B4EDR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics LCP-10G3B4EDR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics LCP-10G3B4EDR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics LCP-10G3B4EDR should contain:
- informations concerning technical data of Delta Electronics LCP-10G3B4EDR
- name of the manufacturer and a year of construction of the Delta Electronics LCP-10G3B4EDR item
- rules of operation, control and maintenance of the Delta Electronics LCP-10G3B4EDR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics LCP-10G3B4EDR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics LCP-10G3B4EDR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics LCP-10G3B4EDR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics LCP-10G3B4EDR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 1 Revision: 0B 2008/9/5 www .deltaww .com 10GBASE-LRM SFP+ Optical T ransceiver Preliminary FEATURES  RoHS compliant  Compliant to SFP+ Electrical MSA SFF-8431  Compliant with SFF-8472 MSA  St andard LC duplex fiber-optic connector  I 2 C for integrated Digital Optical Monitoring  Power con[...]

  • Page 2

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 2 Revision: 0B 2008/9/5 www .deltaww .com Absolute Maximum Ratings Parameter Symbol Min. Ty p . Max. Unit S torage T emperature T S -40 85 ºC Supply V oltage Range @3. 3V V CC3 -0.5 3.6 V Recommended Operating Conditions Parameter Symbol Min. Ty p . Max. Unit Case Operating T emperature T C -5 +70 ºC Suppl[...]

  • Page 3

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 3 Revision: 0B 2008/9/5 www .deltaww .com Operating Ranges (T c = -5 to 70 ) ℃℃ Multimode Fiber T ype Min.Modal Bandwidth (MHz*km) Opterating Range(m) Maximum Channel Insertion Loss (dB) 62.5um MMF OM1 160/500 0.5 to 220 1.9 50um MMF OM2 500/500 0.5 to 220 1.9 50um MMF OM3 1500/500 0.5 to 220 1.9 Optical[...]

  • Page 4

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 4 Revision: 0B 2008/9/5 www .deltaww .com Figure 1. 10GBASE-LRM T ransmitter spectral limit s Optical Receive Characteristics (T c = -5 to 70 ) ℃℃ Parameter Symbol Min. Ty p . Max. Unit Note Signaling speed (nominal ) T S 10.3125 Gb/s Signaling speed variation from nominal. ±100 ppm Center W avelength ?[...]

  • Page 5

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 5 Revision: 0B 2008/9/5 www .deltaww .com SFP+ Transceiver Elect rical Pad Layout Module Electrical Pin Definition Pin Logic Symbol Name/Description Note 1 VeeT Module Transmitter Ground 1 2 LVTTL-O TX_Fault Module Transmitter Fault 2 3 LVTTL-I TX_Disable Transmitter Disable; Turns off transmitter laser outp[...]

  • Page 6

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 6 Revision: 0B 2008/9/5 www .deltaww .com Note: 1. The module signal g round pins, VeeR and VeeT, sha ll be isolated from the module case. 2. This pin is an open collector/drain output pin and shall be pulled up with 4.7k-10k ohms to Ho st_Vcc on the host board. Pull ups can be connected to mult iple po wer [...]

  • Page 7

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 7 Revision: 0B 2008/9/5 www .deltaww .com 4 MOD_ABS Mod_ABS is pulled up to Host_Vcc with 4.7k-10k ohms on the host board and c onnected to VeeT or VeeR in the SFP+ module. MOD_ABS is then asserted “High” when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF8074i) this pin had t[...]

  • Page 8

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 8 Revision: 0B 2008/9/5 www .deltaww .com Recommend Circuit Schematic[...]

  • Page 9

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 9 Revision: 0B 2008/9/5 www .deltaww .com Package Outline Drawing for Metal Housing with Bail de-latch Latch Color Identifier Blue Complies with 21 CFR 1040.10 and 1040.11 Made in x FS FS[...]

  • Page 10

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 10 Revision: 0B 2008/9/5 www .deltaww .com T iming p arameters for SFP+ management Parameter Symbol Min. Max. Unit Note TX_DISABLE Assert time t_off 10 µ sec 1 TX_DISABLE Negate time t_on 2 msec 2 T ime to initialize 2-wire interfase t_2w_sta rt_up 300 msec 3 T ime to initialize t_start_up 300 msec 4 T ime [...]

  • Page 11

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 1 1 Revision: 0B 2008/9/5 www .deltaww .com Enhanced Digit al Diagnostic Interface The memory map in the follo wing describes an extension to the memory map defin ed in SFP MSA. The enhanced interface uses the two wire serial bus address 10100 01X( A2h) to provid e diagnostic information about the module’s[...]

  • Page 12

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 12 Revision: 0B 2008/9/5 www .deltaww .com EEPROM Serial ID Memory Co ntent s (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex A SCII 00 03 43 2D - 86 DC 01 04 44 31 1 87 DC 02 07 45 30 0 88 DC 03 40 46 47 G 89 DC 04 00 47 33 3 90 DC 05 00 48 42 B 91 DC 06 00 49 34 4 92 68 07 00 50 45 E 9[...]

  • Page 13

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 13 Revision: 0B 2008/9/5 www .deltaww .com Digit al Diagnostic Monitoring Interface Alarm and W arning Thresholds (2-Wire Address A2h) Address # Bytes Name V alue (Dec.) Unit Note 00-01 2 T emp High Alarm 85 degree Ce lsius 02-03 2 T emp Low Alarm -10 degree Celsius 04-05 2 T emp High W arning 80 degree Cels[...]

  • Page 14

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 14 Revision: 0B 2008/9/5 www .deltaww .com St ate/ Control Bits Byte Bit Name Description 1 10 7 Tx Disable S tate Digital state of the Tx disable input pin 1 10 6 Soft Tx Disable Read/ Write bit that allow software disable of laser 1 10 5 Reserved 1 10 4 Rate Select St ate Rate Select S tate 1 10 3 Soft Rat[...]

  • Page 15

    LCP-10G3B4EDR DEL T A ELECT RONICS, INC. 15 Revision: 0B 2008/9/5 www .deltaww .com Regulatory Compliance Feature T est Method Reference Performance Electromagnetic Interference (EMI) FCC Part15 Class B EN 55022 Class B (CISPR 22A) Radio Frequency Electromagnetic Field Immunity IEC/EN 61000-4-3 Contact Di scharge IEC/EN 61000-4-2 Electrostatic Disc[...]