Dell MD3660I manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dell MD3660I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dell MD3660I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dell MD3660I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dell MD3660I should contain:
- informations concerning technical data of Dell MD3660I
- name of the manufacturer and a year of construction of the Dell MD3660I item
- rules of operation, control and maintenance of the Dell MD3660I item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dell MD3660I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dell MD3660I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dell MD3660I.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dell MD3660I item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Dell PowerVault MD3660i Series Storage Arrays Deployment Guide[...]

  • Page 2

    Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2012 Dell Inc[...]

  • Page 3

    Contents Notes, Cautions, and Warnings ...................................................................................................2 1 Introduction ..................................................................................................................................7 System Requirements ...........................................[...]

  • Page 4

    Using A DHCP server ........................................................................................................................................27 Using A Static IP Address ................................................................................................................................ 27 Using A DNS Server ..............[...]

  • Page 5

    For Windows Server 2008 GUI Version ............................................................................................................ 42 For Windows Server 2008 Core Version ........................................................................................................... 42 For Linux Server .....................................[...]

  • Page 6

    6[...]

  • Page 7

    1 Introduction This guide provides information about deploying Dell PowerVault MD3660i storage arrays. The deployment process includes: • Hardware installation • Modular Disk Storage Manager (MD Storage Manager) installation • Initial system configuration Other information provided include system requirements, storage array organization, and [...]

  • Page 8

    One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths between the host(s) and the storage array so that loss of any single path (for example, through failure of a host server port) does not result in loss of access to data on the storage array. The storage arr[...]

  • Page 9

    2 Hardware Installation Before using this guide, ensure that you review the instructions in the: • Getting Started Guide —The Getting Started Guide that shipped with the storage array, provides information to configure the initial setup of the system. • Dell PowerVault MD3260/3260i/3660i/3660f/3060e Storage Arrays Administrator's Guide ?[...]

  • Page 10

    Redundant And Non-Redundant Configurations Non-redundant configurations are configurations that provide only a single data path from a host to the storage array. This type of configuration is only recommended for non-critical data storage. Path failure from a failed or removed cable, a failed HBA, or a failed or removed RAID controller module resul[...]

  • Page 11

    Figure 1. Four Hosts in a Dual-Controller Configuration In the following figure, up to two servers are directly attached to the RAID controller modules. If the host server has a second Ethernet connection to the array, it can be attached to the iSCSI ports on the array's second controller. This configuration provides improved availability by a[...]

  • Page 12

    Figure 2. Two Hosts Connected to Two Controllers In the following figure, up to two cluster nodes are directly attached to two RAID controller modules. Since each cluster node has redundant paths, loss of a single path still allows access to the storage array through the alternate path. 12[...]

  • Page 13

    Figure 3. Two Cluster Nodes Connected to Two Controllers 13[...]

  • Page 14

    Network-Attached Configurations You can also cable the host servers to the RAID controller module iSCSI ports through industry-standard 10 Gbps or 1 Gbps Ethernet switches. An iSCSI configuration that uses Ethernet switches is frequently referred to as an IP SAN. By using an IP SAN, the PowerVault MD3660i series storage array can support up to 64 h[...]

  • Page 15

    Figure 4. 64 Servers Connected to Two Controllers The following figure shows up to 64 stand-alone servers attached (using multiple sessions) to a dual RAID controller configuration through a network using a 1 Gbps to 10 Gbps aggregation scheme. The NICs on the servers are 1 Gbps NICs and the uplink ports on the 1 Gbps switches are 10 Gbps. Hosts th[...]

  • Page 16

    network allow two separate physical paths for each host, which ensures full redundancy if one of the paths fails. It is recommended you use two switches for more redundancy. However, single switch configuration is also supported. Figure 5. 64 Servers Connected to Two RAID Controllers 16[...]

  • Page 17

    Cabling PowerVault MD3060e Expansion Enclosures You can expand the capacity of your PowerVault MD3660i Series storage array by adding PowerVault MD3060e expansion enclosures. You can expand the physical disk pool to a maximum of 120 (or 180, if enabled using Premium Feature activation) physical disks using a maximum of two expansion enclosures. Exp[...]

  • Page 18

    15. After the PowerVault MD3060e Series expansion enclosure is configured as an expansion enclosure of the storage array, restore the data that was backed up in step 1. Expanding With New PowerVault MD3060e Expansion Enclosures Perform the following steps to attach new PowerVault MD3060e expansion enclosures to a PowerVault MD3660i Series storage a[...]

  • Page 19

    3 Installing MD Storage Manager The PowerVault MD Series resource media contains software and drivers for both Linux and Microsoft Windows operating systems. The root of the media contains a readme.txt file covering changes to the software, updates, fixes, patches, and other important data applicable to both Linux and Windows operating systems. The[...]

  • Page 20

    Graphical Installation (Recommended) The MD Storage Manager configures, manages, and monitors the storage array. To install the MD storage manager: 1. Insert the PowerVault MD Series resource media. Depending on your operating system, the installer may launch automatically. If the installer does not launch automatically, navigate to the root direct[...]

  • Page 21

    Silent Installation Silent Installation On Windows To run silent installation on a Windows system: 1. Copy the custom_silent.properties file in the /windows folder of the installation media or image to a writable location on the host server. 2. Modify the custom_silent.properties file to reflect the features, models and installation options to be u[...]

  • Page 22

    22[...]

  • Page 23

    4 Post Installation Tasks Before using the storage array for the first time, complete a number of initial configuration tasks in the order shown. These tasks are performed using the MD Storage Manager. NOTE: If Dynamic Host Configuration Protocol (DHCP) is not used, initial configuration using the management station must be performed on the same ph[...]

  • Page 24

    iSCSI Configuration Worksheet The IPv4 Settings — Worksheet and IPv6 Settings — Worksheet helps you plan your configuration. Recording host server and storage array IP addresses at a single location enables you to configure your setup faster and more efficiently. Guidelines For Configuring Your Network For iSCSI provides general network setup g[...]

  • Page 25

    Storage Array Configuration Before a host iSCSI initiator and an iSCSI-based storage array can communicate, they must be configured with information such as which IP addresses and authentication method to use. Since iSCSI initiators establish connections with an already configured storage array, the first task is to configure your storage arrays to[...]

  • Page 26

    • For redundancy in a dual controller (duplex) configuration, ensure each host network interface is configured to connect to both storage array controllers. • For optimal load balancing, ensure each host network interface that is used for iSCSI traffic is configured to connect to each storage array controller. • It is recommended that each ho[...]

  • Page 27

    5 Guidelines For Configuring Your Network For iSCSI This section provides general guidelines for setting up your network environment and IP addresses for use with the iSCSI ports on your host server and storage array. Your specific network environment may require different or additional steps than shown here, so make sure you consult with your syst[...]

  • Page 28

    3. Restart network services using the following command: /etc/init.d/network restart Using A DNS Server If you are using static IP addressing: 1. In the Control Panel , select Network connections or Network and Sharing Center and then click Manage network connections . 2. Right-click the network connection you want to configure and select Propertie[...]

  • Page 29

    NETWORKING=yes HOSTNAME=mymachine.mycompany.com 2. Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-scripts/ifcfg-ethX (for Red Hat Enterprise Linux) or /etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX (for SUSE Enterprise Linux). BOOTPROTO=dhcpm Also, verify that an IP address and netmask are no[...]

  • Page 30

    30[...]

  • Page 31

    6 Uninstalling MD Storage Manager Uninstalling MD Storage Manager From Windows Uninstall MD Storage Manager From Microsoft Windows Operating Systems Other Than Microsoft Windows Server 2008 Use the Change/Remove Program feature to uninstall the Modular Disk Storage Manager from Microsoft Windows operating systems other than Microsoft Windows Server[...]

  • Page 32

    Uninstalling MD Storage Manager From Linux By default, PowerVault MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory. If another directory was used during installation, navigate to that directory before beginning the uninstallation procedure. 1. From the installation directory, open the Uninstall Dell MD Storage Software di[...]

  • Page 33

    7 Appendix — Manual Configuration Of iSCSI The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before beginning, it is important to understand where each of these steps occur in relation to your host server or storage array environment. The table below shows each iSCSI configuration step [...]

  • Page 34

    You can discover the storage array either automatically or manually. Automatic Storage Array Discovery 1. Launch MD Storage Manager . If this is the first storage array to be set up, the Add New Storage Array window is displayed. 2. Select Automatic and click OK . After discovery is complete, a confirmation screen is displayed. It may take several [...]

  • Page 35

    Task Purpose degrades or fails, or an adverse environmental condition occurs. Configure a storage array To create virtual disks and map them to hosts. Step 2: Configure The iSCSI Ports On The Storage Array By default, the iSCSI ports on the storage array are set to the following IPv4 settings: Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask: [...]

  • Page 36

    3. Under Target Portals , click Add and enter the IP address or DNS name of the iSCSI port on the storage array. 4. If the iSCSI storage array uses a custom TCP port, change the Port number. The default is 3260. 5. Click Advanced and set the following values on the General tab: – Local Adapter — Must be set to Microsoft iSCSI Initiator. – Sou[...]

  • Page 37

    d) Save and close the /etc/iscsi/iscsid.conf file. 5. From the console, restart the iSCSI service with the following command: service iscsi start 6. Verify that the iSCSI service is running during boot using the following command from the console: chkconfig iscsi on 7. To display the available iSCSI targets at the specified IP address, use the foll[...]

  • Page 38

    Mutual CHAP In addition to setting up target CHAP, you can set up mutual CHAP in which both the storage array and the iSCSI initiator authenticate each other. To set up mutual CHAP, configure the iSCSI initiator with a CHAP secret that the storage array must send to the host sever in order to establish a connection. In this two-way authentication p[...]

  • Page 39

    CHAP Setting Description CHAP If CHAP is selected and None is deselected, the storage array requires CHAP authentication before allowing access. 2. To configure a CHAP secret, select CHAP and select CHAP Secret . 3. Enter the Target CHAP Secret (or Generate Random Secret ). Confirm it in Confirm Target CHAP Secret and click OK . Although the storag[...]

  • Page 40

    The iSCSI port you configured on the storage array during target discovery disappears. 6. Under Target Portals , click Add and re-enter the IP address or DNS name of the iSCSI port on the storage array (removed above). 7. Click Advanced and set the following values on the General tab: – Local Adapter — Should always be set to Microsoft iSCSI In[...]

  • Page 41

    3. If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of the target(s) by the initiator by editing the following lines: node.session.auth.username_in=<iscsi_target_username> node.session.auth.password_in =<CHAP_target_password> 4. To set up discovery session CHAP authentication, f[...]

  • Page 42

    Step 7: Connect To The Target Storage Array From The Host Server For Windows Server 2008 GUI Version 1. Click Start → Program → Microsoft iSCSI Initiator or Start → All Programs → Administrative Tools → iSCSI Initiator. 2. Click the Targets tab. If previous target discovery was successful, the IQN of the storage array should be displayed [...]

  • Page 43

    TCP_Port_Number_Of_Target_Portal * * * Login_Flags * * * * * Username Password Authtype * Mapping_Count where – <Target_Name> is the target name as displayed in the target list. Use the iscsicli ListTargets command to display the target list. – <Report_To_PNP > is T, which exposes the LUN to the operating system as a storage device.[...]

  • Page 44

    Step 8: (Optional) Set Up In-Band Management Out-of-band management (see Step 1: Discover the Storage Array (Out-of-band Management Only) ) is the recommended method for managing the storage array. However, to optionally set up in-band management, use the steps shown below. The default iSCSI host port IPv4 addresses are displayed below for referenc[...]

  • Page 45

    8 Appendix — Using Internet Storage Naming Service Internet Storage Naming Service (iSNS) server, supported only on Microsoft Windows iSCSI environments, eliminates the need to manually configure each individual storage array with a specific list of initiators and target IP addresses. Instead, iSNS automatically discovers, manages, and configures[...]

  • Page 46

    46[...]

  • Page 47

    9 Appendix — Load Balancing Windows Load Balance Policy Multi-path drivers select the I/O path to a virtual disk through a specific RAID controller module. When the multi-path driver receives a new I/O, the driver tries to find a path to the current RAID controller module that owns the virtual disk. If that path cannot be found, the multi-path dr[...]

  • Page 48

    The Computer Management window is displayed. 2. Click Device Manager to show the list of devices attached to the host. 3. Right-click the multi-path disk device for which you want to set load balance policies, then select Properties . 4. From the MPIO tab, select the load balance policy you want to set for this disk device. Changing The Load Balanc[...]

  • Page 49

    Figure 6. Initiator Configuration Two sessions with one TCP connection are configured from the host to each controller (one session per port), for a total of four sessions. The multi-path failover driver balances I/O access across the sessions to the ports on the same controller. In a duplex configuration, with virtual disks on each controller, cre[...]

  • Page 50

    50[...]

  • Page 51

    10 Appendix — Stopping And Starting iSCSI Services In Linux To manually stop the iSCSI services in Linux, certain steps must be followed to maintain parallel processing between the storage array and the host server. 1. Stop all I/O. 2. Unmount all correlated file systems. 3. Stop iSCSI service by running the following command: /etc/init.d/open-is[...]

  • Page 52

    52[...]

  • Page 53

    11 IPv4 Settings — Worksheet NOTE : If you need additional space for more than one host server, use an additional sheet. Static IP address (host server) Subnet (should be different for each NIC) Default gateway iSCSI port 1 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ iSCSI port 2 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ _[...]

  • Page 54

    Static IP address (host server) Subnet Default gateway iSCSI port 1, In 0 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ iSCSI port 1, In 1 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ Management port cntrl 1 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ 54[...]

  • Page 55

    12 IPv6 Settings — Worksheet NOTE : If you need additional space for more than one host server, use an additional sheet. Host iSCSI port 1 Host iSCSI port 2 Link local IP address ___ . ___ . ___ . ___ Link local IP address ___ . ___ . ___ . ___ Routable IP address ___ . ___ . ___ . ___ Routable IP address ___ . ___ . ___ . ___ Subnet prefix ___ .[...]

  • Page 56

    Router IP address ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ iSCSI controller 0, In 1 IP address FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ Routable IP address 1 ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ Routable IP address 2 ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ Router IP address ____ : ____ : ____[...]