Dayton 4E769B manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dayton 4E769B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dayton 4E769B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dayton 4E769B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dayton 4E769B should contain:
- informations concerning technical data of Dayton 4E769B
- name of the manufacturer and a year of construction of the Dayton 4E769B item
- rules of operation, control and maintenance of the Dayton 4E769B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dayton 4E769B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dayton 4E769B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dayton service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dayton 4E769B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dayton 4E769B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operating Instructions & Parts Manual Dayton Pr opane Construction Heater Description Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater uses propane gas for combustion and electricity to run the motor. It is primarily intended for temporary heating of buildings under construction, alteration, or repair. This heater [...]

  • Page 2

    Dayton Operating Instructions and Parts Manual 2 Dayton Pr opane Construction Heater ® 4E769B General Safety Information Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these s[...]

  • Page 3

    Dayton Operating Instructions and Parts Manual 3 Model 4E769B Version B - For Reduction G016.J ® Specifications ELECTRICAL SPECIFICA TIONS Electrical Input Amperage 120 V olt/60Hertz 2 General Safety Information (Continued) Manifold Hot Air Output Supply Pressur e T emperature Range Pressur e (CFM Approx) Ignition T o Regulator For Operating Heate[...]

  • Page 4

    Dayton Operating Instructions and Parts Manual 4 Dayton Pr opane Construction Heater ® 4E769B Product Identification Figure 2 – Model 4E769B Shell Handle Motor Power Cord Hot Air Outlet (Front) Fan Guard Heater Base Piezo Ignitor Button Automatic Control V alve Button Inlet Connector Hose /Regulator Assembly[...]

  • Page 5

    Dayton Operating Instructions and Parts Manual 5 Model 4E769B Version B - For Reduction G016.J ® A verage T emperature Number of T anks ( o F) at T ank Location (100 pound) 40 ° 1 32 ° 1 20 ° 1 10 ° 1 0 ° 1 -10 ° 2 -20 ° 2 Pr opane Supply Propane gas and propane tank(s) must to provided by the customer . Use this heater only with a propane [...]

  • Page 6

    Dayton Operating Instructions and Parts Manual 6 Dayton Pr opane Construction Heater ® 4E769B Installation Review and understand the warnings in the General Safety Infor - mation Section. They are needed to safely operate this heater . Follow all local codes when using this heater . T est all gas piping and connections for leaks after installation[...]

  • Page 7

    Dayton Operating Instructions and Parts Manual 7 Model 4E769B Version B - For Reduction G016.J ® Operation (Continued) NOTE : If not opened slowly , excess-flow check valve on propane tank will stop gas flow . If this happens, close propane supply valve and open again slowly . Be sure motor and fan are running before pushing in automatic contr o[...]

  • Page 8

    Dayton Operating Instructions and Parts Manual 8 Dayton Pr opane Construction Heater ® 4E769B Figure 11 - Removing Motor and Fan Guard from Heater Maintenance (Continued) SERVICE PROCEDURES Never attempt to service heater while it is connected to propane supply , operating, or hot. Sever e burns and electrical shock can occur . ELECTRICAL SYSTEM T[...]

  • Page 9

    Dayton Operating Instructions and Parts Manual 9 Model 4E769B Version B - For Reduction G016.J ® Ignitor Ignitor Mounting Screw Rear Head Figure 15 - Removing Ignitor Mounting Screw and Ignitor 7. Set gap between ignitor electrode and target plate to .17" (See Figure 16). Figure 13 - Replacing Motor and Fan Guard into Heater 9. Place motor an[...]

  • Page 10

    Dayton Operating Instructions and Parts Manual 10 Dayton Pr opane Construction Heater ® 4E769B 4E769B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger P[...]

  • Page 11

    Dayton Operating Instructions and Parts Manual 11 Model 4E769B Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 4E769B Replacement Parts List Reference Number Description Part No. Quantity 1 Inner shell (Combustion Chamber) 099568-01 1 2 #10-16 x 3/8" Hex tap screw *M11084-26 7 3 Outer shell 099599-01AZ 1 4 Ha[...]

  • Page 12

    Dayton Operating Instructions and Parts Manual 12 Dayton Pr opane Construction Heater ® 4E769B Never attempt to service heater while it is connected to propane supply , operating, or hot. Severe burns and electrical shock can occur . T roubleshooting Chart Symptom Possible Cause(s) Corrective Action 1. No electrical power to heater 2. Fan hitting [...]

  • Page 13

    Dayton Operating Instructions and Parts Manual 13 Model 4E769B Version B - For Reduction G016.J ® 4E769B Description Part No. 10' Rubber Hose with Brass Fitting LP A1020 U.L. listed. 15' Rubber Hose with Brass Fitting LP A1030 U.L. listed. Propane Gas Regulator LP A2110 U.L. listed. Hose/Regulator Assembly LP A3090 U.L. listed. Fuel Gas [...]

  • Page 14

    Dayton Operating Instructions and Parts Manual 14 Dayton Pr opane Construction Heater ® 4E769B Notes ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ______________[...]

  • Page 15

    Dayton Operating Instructions and Parts Manual 15 Model 4E769B Version B - For Reduction G016.J ® 4E769B Notes ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ____[...]

  • Page 16

    Dayton Operating Instructions and Parts Manual 16 Dayton Pr opane Construction Heater ® 4E769B 101427-01 Rev . B 01/00 Version B - For Reduction G016.J ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Natural gas construction heater, Models covered in this manual are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against [...]