Datalogic Scanning DS4600A manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Datalogic Scanning DS4600A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Datalogic Scanning DS4600A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Datalogic Scanning DS4600A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Datalogic Scanning DS4600A should contain:
- informations concerning technical data of Datalogic Scanning DS4600A
- name of the manufacturer and a year of construction of the Datalogic Scanning DS4600A item
- rules of operation, control and maintenance of the Datalogic Scanning DS4600A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Datalogic Scanning DS4600A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Datalogic Scanning DS4600A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Datalogic Scanning service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Datalogic Scanning DS4600A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Datalogic Scanning DS4600A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DS4600A Laser Barcode Reader Quick Reference Guide The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. For installation, use and maintenance it is not necessary to open the device. There is a safety device which allow s the laser to be switched on on[...]

  • Page 2

    DS4600A QUICK GUIDE 2 Av ailable Models: DS4600A - X X X X De co ding M ode 2 = Standard w/ Di sp lay 3 = Advanced Code Reconstruction Reading Range 0 = M edi um Range 1 = Long Ran ge 2 = Short Range Optic V ersion 0 = Li near 1 = Ra s ter R 1 2 = Ra s ter R 2 Special Features 0 = Standard 5 = Integrated Heater The follow ing table displays each ve[...]

  • Page 3

    DS4600A QUICK GUIDE 3 Accessories: Name Description Part Number C-BOX 100/200 Connection Box 93ACC1510, 93ACC1520 C-BOX 300/310 Connection Box Profibus 93A301000, 93A301030 GFC-41 90° Reading Device 91D081000 OM 4000 Oscillating Mirror 93A251030 INT-24 20 mA Current Loop Interface Board 93A151000 Electrical Connections: DS4600A is equipped with a [...]

  • Page 4

    DS4600A QUICK GUIDE 4 Mechanical Installation: 10 0.39 41.8 1.6 4 M4 N° 4 37 1.47 5 0.2 11.8 0.46 81 3.19 8.25 0.32 87.9 3.46 M4 N°2 58 2.28 32.5 1.28 3.75 0.15 42 1.65 20 0.79 83. 5 3.29 101 3.98 18 0.70 0.90 23 DS4600A 37 20.2 1.4 6 22* 0.8 6 0.8 14.8 0.58 39.4 1.5 5 * The quote refer s to th e scan l ine Mounting hole depth M4 X 5 Figure - Ov [...]

  • Page 5

    DS4600A QUICK GUIDE 5 Connectivity : Point-to-point lay out c Main Serial Inte rface d Auxiliary Serial Interface (Loc al Echo) (RS232) e External Trigger (for On-Li ne Mode) Pass-through lay out Multiplexer lay out c Main Serial Int erface (RS232) c Main Serial In t erf ace (RS485 Half -Dupl ex) d Auxiliary Serial Interface (RS 232) d Auxiliary Se[...]

  • Page 6

    DS4600A QUICK GUIDE 6 Reading Diagrams: DS4600A-210X (Long R ange) CONDITIONS Code = Interleaved 2/ 5 or Code 39 PCS = 0.90 Pitc h angl e = 0° Skew angle = 15° Tilt angle = 0° *Code Resoluti on: Standard - for 0. 50 mm (20 mils ) codes and greater *Code Reading Condition: Standard * Paramet er select abl e in W i nHos t. 4 -4 12 -12 -16 (in) 04 [...]

  • Page 7

    DS4600A QUICK GUIDE 7 Reading Diagrams: DS4600A-22XX (Shor t Range) CONDITIONS Code = Interleaved 2/ 5 or Code 39 PCS = 0.90 "Pitc h" angle = 0 ° "Skew" angle = 10 ° "Tilt" angl e = 0 ° *SW Resolut i on = Hi gh * Paramet er select abl e in W i nHos t 2 1 0 -1 5 4 3 -2 -3 -4 -5 (in) 01 3 21 0 6 (in) 45 7 8 9 0 20 40 [...]

  • Page 8

    DS4600A QUICK GUIDE 8 Reading Diagrams: DS4600A-2X1X (R aster R1) CONDITIONS Code = Interleaved 2/ 5 or Code 39 PCS = 0.90 "Pitc h" angle = 0° "Skew" angle = 18° "Tilt" angle = 0° *Code Resoluti on: High - for 0.30 m m (12 m ils) c odes and smaller Standard - for 0. 50 mm (20 mils ) codes and greater *Code Reading C[...]

  • Page 9

    DS4600A QUICK GUIDE 9 DS4600A-31XX (Long R ange) CONDITIONS Code = Interleaved 2/ 5 and Code 39 "Pitc h" angle = 0 ° "Skew" angle = 15 ° "Tilt" angl e = 0 ° *Code Resolution = Standard for 0. 50 mm (20 mils ) codes and greater *Code Reading Conditions = Standard * Paramet er select abl e in W i nHos t 4 -4 12 -12 -1[...]

  • Page 10

    DS4600A QUICK GUIDE 10 DS4600A-32XX (Shor t Range) CONDITIONS Code = Interleaved 2/ 5 and Code 39 PCS = 0.90 "Pitc h" angle = 0° "Skew" angle = 15° "Tilt" angle = 0° *SW Resolut i on: High * Paramet er select abl e in W i nHos t. 4 2 0 -2 10 8 6 -4 -6 -8 -10 (in) 02 6 42 0 12 (in) 8 10 14 16 18 0 40 80 120 16 0 200 [...]

  • Page 11

    DS4600A QUICK GUIDE 11 User Interface: RS232 PC-side connections 1 5 9 6 9-pin male conne ctor 13 25 14 1 25-pin male c onnector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger [...]

  • Page 12

    DATA LOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara c he declares t hat the déclare que le bescheini gt , daß das Gerät declare que el DS4600A -XXXX Laser Scanner e tutti i s uoi modell i and all its models et tous s es modèl es und seine m odelle y todos s us modelos sono conf orm i alle Diret tive del Consi g[...]