Cuno SQC Pro manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cuno SQC Pro, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cuno SQC Pro one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cuno SQC Pro. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cuno SQC Pro should contain:
- informations concerning technical data of Cuno SQC Pro
- name of the manufacturer and a year of construction of the Cuno SQC Pro item
- rules of operation, control and maintenance of the Cuno SQC Pro item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cuno SQC Pro alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cuno SQC Pro, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cuno service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cuno SQC Pro.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cuno SQC Pro item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    © 2001 CUNO Incorporated 98-91220 0601 CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.waterfactorysystems.com • www.cuno.com[...]

  • Page 2

    INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems ® SQC Series Reverse Osmosis (RO) Drinking Water Appliances. Please read each section of this manual care - fully. The specific model chosen should be appropriate for the local water conditions and the customer's needs. Check the Perform[...]

  • Page 3

    A. DETERMINE THE APPLIANCE LOCATION The appliance can be located under a sink or in a basement depending on space availability and the customer's preference. If a basement installation is selected, additional tubing, hardware and fittings may be needed and a hole will have to be made from inside the cabinet, through the floor, to the basement.[...]

  • Page 4

    C. PREPARE THE APPLIANCE FOR INSTALLATION Open the shipping carton and remove the components. Check to see that all of the installation parts are present. They should include the purification assembly, storage tank, faucet, installation hardware, RO membrane cartridge and tubing. Check to see that the air supply in the empty tank is approxi - matel[...]

  • Page 5

    E. MOUNT THE FAUCET Undercounter installations generally require that the faucet's built-in air gap be used. In basement installations, the built-in air gap does not have to be used if one is provided elsewhere on the drain line. For Basement Installations Without An Air Gap Module See Installation Instructions O. IMPORTANT: The Uniform Plumbi[...]

  • Page 6

    F . INSTALL THE FEED WATER TAPPING VALVE AND TUBING The feed water tapping valve which is supplied, is designed to be used on 3/8" to 1/2" OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use it on flexi - ble ribbed tubing, because it has too thin a wall thickness and it requires special hardware. Soft Copper Tubing [...]

  • Page 7

    5) Turn the feedwater tapping valve handle clockwise to close the valve. With a wrench, tighten the nut/seal around the valve handle stem. 6) Remove the cover from the appliance and disconnect the orange 1/4" tubing from the feedwater fitting. (See Fig. 6) 7) Connect one end of the orange tubing to the feedwater tapping valve using the brass c[...]

  • Page 8

    I. INSTALL THE PURIFICATION ASSEMBLY AND STORAGE TANK For Basement Installation See Installation Instructions O. Undercounter Installation: The purification assembly is usually mounted to the right or the left side wall inside of the sink cabinet, taking into consider - ation the space available and the tank location. Generally, the storage tank is[...]

  • Page 9

    L. START UP THE APPLIANCE 1) Double check to see that all of the connections are secure. 2) Open the feedwater tapping valve and check the appliance for leaks. If any leaks are detected, close the valve and correct the problem before proceeding. NOTE: If a leak occurs at a "Push In" plastic fitting, then refer to Fig. 6. 3) Open the stora[...]

  • Page 10

    O. APPENDIX FOR BASEMENT INSTALLATIONS The following variations are generally required for basement installations: INSTALL THE DRAIN CONNECTION For basement installations, the drain saddle is generally not used. Instead, the RO reject line (SFC tubing) is routed so that it drains into a laundry sink, floor drain, or standpipe through an approved ai[...]

  • Page 11

    Teflon is a registered trademark of E.I. DuPont 11 P. INSTALLATION TROUBLESHOOTING Problem: Leak at the feedwater tapping valve. Cause: Tapping valve is not clamped tightly enough. Solution: Tighten the tapping valve clamp screws evenly and firmly keeping both halves of the bracket parallel. Be sure not to deform tubing. Problem: Leak at the drain [...]

  • Page 12

    A. IMPORTANT WATER QUALITY ASSURANCE REQUIREMENTS Reverse Osmosis drinking water appliances contain treat - ment components that are critical for the effective reduction of Total Dissolved Solids (TDS) as well as inorganic chemical contaminants. Water Factory Systems ® strongly recommends that the user test the water periodically (every six months[...]

  • Page 13

    C. REPLACING THE RO MEMBRANE CARTRIDGE The life of the RO membrane cartridge depends on the local water conditions and proper maintenance, e.g., regular fil - ter changes. Under typical conditions, the RO membrane life ranges from 18-36 months. Unlike the filter cartridges, the RO membrane cartridge life is not determined by the amount of water use[...]

  • Page 14

    4) Fill the sanitizing device with the following recommended dosage of common household bleach: • A standard 2.5 gallon tank - 1/2 teaspoon (3 ml) • Alternate size tanks - 1/2 teaspoon (3 ml) per 2.5 gallons of tank capacity 5) Open the feedwater tapping valve to force water and sanitizer into the storage tank. Allow about three (3) minutes to [...]

  • Page 15

    Appendix 1. Electrical Diagram 15[...]