Crestron CRESTRON GREEN LIGHT Power Switching manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Crestron CRESTRON GREEN LIGHT Power Switching, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Crestron CRESTRON GREEN LIGHT Power Switching one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Crestron CRESTRON GREEN LIGHT Power Switching. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Crestron CRESTRON GREEN LIGHT Power Switching should contain:
- informations concerning technical data of Crestron CRESTRON GREEN LIGHT Power Switching
- name of the manufacturer and a year of construction of the Crestron CRESTRON GREEN LIGHT Power Switching item
- rules of operation, control and maintenance of the Crestron CRESTRON GREEN LIGHT Power Switching item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Crestron CRESTRON GREEN LIGHT Power Switching alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Crestron CRESTRON GREEN LIGHT Power Switching, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Crestron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Crestron CRESTRON GREEN LIGHT Power Switching.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Crestron CRESTRON GREEN LIGHT Power Switching item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CRESTRON GREEN LIGHT™ Power Switching Introduction CRESTRON GR EEN LIGHT power switc hing cabinets c ome pre-c onfigured wi th GLXP m odules already installed. The cabinets o nly require installat ion and wiri ng of feed a nd load circui ts. Industry Compliance The cabinet an d modules are Listed to appl icable UL Stan dards and req uirements by [...]

  • Page 2

    Power Switching CRESTRON GREEN LIGHT™ Physical Description This section shows the ex terior and interior di mensions of t he CRESTRO N GREEN LIGHT cabinet. External Dimensions of CRESTRON GREEN LIGHT Power Switching Cabinets KNOCK OUT (FOR 3 4 " (19 MM) CONDUIT) TYPIC A L B OTH SI DES TECHNICAL KNOCKOUTS, 50 TOTAL (FOR 3 4 " (19 mm) &am[...]

  • Page 3

    CRESTRON GREEN LIGHT™ Power Switching Interior Dimensions of CRESTR ON GREEN LIGHT Cabinets (120/208 VAC, left; 277/480 VA C, right) H1 H1 1 7 8 " (48 mm) 8 1 8 " (2 07 mm) 1 7 8 " (48 mm ) 6 1 4 " (1 59 mm) 2" (51 mm ) 2" (51 mm ) 8" (2 0 4 mm) 3 7 8 " (99 mm) Interior Dimensions of CRES TRON GREEN LIGHT C[...]

  • Page 4

    Power Switching CRESTRON GREEN LIGHT™ Installation Observe the following when installing the cabinet: • The cabinet m ust be mounte d by a licensed electrician in accorda nce with all nati onal and local codes. Refer to the diagram below for specific requirem ents. • The cabinet is designed for s urface mounting on a wall. • Cabinets are in[...]

  • Page 5

    CRESTRON GREEN LIGHT™ Power Switching Wiring NOTE: All wiri ng must be i nstalled in acc ordance with all local and nati onal electrical codes. NOTE: Refer to t he torque set tings specified o n pages 6, 7 and 8. CRESTRON GREEN LIGHT cabinets are shippe d with GLXP mo dules installed and prewired to the branch circuit breakers. The following m us[...]

  • Page 6

    Power Switching CRESTRON GREEN LIGHT™ Feed Wiring (Section A) Feed Wiring for MLO (left) and MCB (right) Applicat ions Refer to the foll owing table for inform a tion on wiring the feed to the panel. Feed Wire Information 120 Volt Models 277 Volt Models TERMINAL CONNECTOR MAX WIRE RANGE TORQUE Max Current CONNECTOR MAX WIRE RANGE TORQUE Max Curre[...]

  • Page 7

    CRESTRON GREEN LIGHT™ Power Switching Load Wiring (Section B) CAUTION: Bypass jum pers are provided on each output to allow testing an d to protec t the module duri ng installation. The jumper shorts the L and SW terminals so that th e load circu it is energized when the branch breake r is on. Do not remove t he bypass j umper unti l all feed and[...]

  • Page 8

    Power Switching CRESTRON GREEN LIGHT™ The GLXP-DIMFLV 8 also requi res wirin g the term inals for 0-10 VDC cont rol wire. Refer to the following diagram when connecting the dimmable ballast. Each control wire terminal accepts one 12 – 28 AWG wire. 0-10 VDC Control Wiring for GLXP-DIMFLV8 Only TO + ON 4-WIRE LOADS (PURPLE ) TO - ON 4-WIRE L OADS[...]

  • Page 9

    CRESTRON GREEN LIGHT™ Power Switching Connector Wiring RED WHITE BLUE BLACK NET: TO CONTROL SYSTEM AND OTHER CRESNE T DEVICES POWER: 24 VDC JUMPERED FRO M NET PORT or EX TERNAL S UPPLY. PROVIDES CRESNET PO WER TO THE MODULES OVERRIDE: FROM DEVI CE PROVIDING CONTACT CLOSU RE & TO OTHER DEVI CES RECEIVING OVERRIDE SIGNAL NET Port Wiring When wi[...]

  • Page 10

    Power Switching CRESTRON GREEN LIGHT™ To power the modules ext ernally from a Cresnet 24 VDC power suppl y, connect the external p ower sup ply to the EXT and G pins on the POWER suppl ied connector as shown in t he followi ng diagram . Providing Cresnet Power Externally CRESTRON 24 VDC POWER SUPP LY G 24 When properly connected a nd r eceiving 2[...]

  • Page 11

    CRESTRON GREEN LIGHT™ Power Switching Testing Manual Control A lighting module can be manuall y controlle d from its front pa nel. GLXP-SW and GLXP-HSW Modules: The state of ea ch output ca n be manual ly controlle d from t he front panel. To toggle the outpu t between off and on , tap the appropriate ON/OFF button. The c orresponding LE D illumi[...]

  • Page 12

    Power Switching CRESTRON GREEN LIGHT™ System Operation and Commissioning This cabinet has been desig ned as a com ponent of a pro grammed C restron system. Sy stem comm issioning by an authorized Crestr on representative must be performed to ensu re system operatio n. Once the cabi net has been wired and the m odules have bee n tested, contact Cr[...]

  • Page 13

    CRESTRON GREEN LIGHT™ Power Switching Problem Solving Troubleshooting The following table prov ides corrective action for po ssible trouble situations. If further assistance is required, please contact a Crestron custom er service representative. Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTIO N Power not delivered to the module. If th[...]

  • Page 14

    Power Switching CRESTRON GREEN LIGHT™ Appendix A: Setting Module Net IDs The following procedure will normally be performed by an au thor ized Crestron representative as part of the System Commissioni n g pha se. For system wiri ng and basic te sti n g as desc ri be d on pages 5 and 11, it is not nec essary to perform this step. Only perform this[...]

  • Page 15

    CRESTRON GREEN LIGHT™ Power Switching Appendix B: Module Specifications Specifications for the GLXP modules are li sted in the following tabl e. GLXP Module Specification s SPECIFICATION GLXP-SW10 GLXP-SW16 GLXP-HSW8 GL XP-HSW12 GLXP-DIMFLV8 Description 10 Channel Switch Module 16 Channel Switch Module 8 Channel High- Inrush Switch Module 12 Chan[...]

  • Page 16

    Power Switching CRESTRON GREEN LIGHT™ Return and Warranty Policies Merchandise Returns / Repair Service 1. No mer ch and ise may be r etu rne d for credit, exchange or service without prior authorizatio n from CRESTRON. To obtain w arranty service for CRESTRON pro ducts, conta ct an authori zed CRESTRON dealer. Only authori zed CRESTRON dealers m[...]